2020 changes series: Article 392

  Переглядів 8,417

Ryan Jackson

Ryan Jackson

День тому

This short video covers the changes in the 2020 NEC to Article 392, Cable Trays.

КОМЕНТАРІ: 19
@jordanharris3553
@jordanharris3553 2 роки тому
One of the cutest intro as I’ve ever seen!
@mattmclaughlin7338
@mattmclaughlin7338 3 роки тому
thank you ! your content is very much appreciated. if you could produce a video like this every day . I'm sure youtube algorithm will pick up very fast like it did for Daily Electrician.
@Voltage06888
@Voltage06888 2 роки тому
Awesome!!! Thanks Ryan 👍
@johnkulpowich5260
@johnkulpowich5260 3 роки тому
Can't stand the wannabe electricains on you tube. Your one of the best
@vishalgulati5847
@vishalgulati5847 2 роки тому
Thank you very much for this Video. may you please help me out for short questions :- 1. is it mandatory to install cover on ladder type cable Tray ? cable tray will be installed in a metallic container. and not approachable to user. 2. if Cable is not Tray Type listed, but approved with UL: AWM 10107 & NFPA79. can we install such kind of cable in Cable Tray ? The cable is for example ÖLFLEX FD 90/90 CY which is flexible power cable to connect the machine. Installation is in Metallic container and Length is not more than 10meter. 3. I also heard that it always depend upon customer to customer and area to area by which standards they want to inspect. it can be NEC or can be NFPA79. with NFPA79 its not an issue to install not listed Type cable installation in cable Tray But with NEC, yes its an issue. is this true ?
@TheJoypool
@TheJoypool 11 місяців тому
Can lv cables cross @90 degrees over each other on cable trays?
@j81851
@j81851 Рік тому
Cable tray is a UL listed for the purpose and is a RACEWAY just like conduit. This is very important. Loose cable or jacked cables must be TC or Tray Cable rated required. UV or sunlight resistant is required. As always it must be installed per the manufacturer's recommendation and per listing and labeling. Thanks for you content it is very good however at any time we discuss tray I suggest we review the unique status of this type of raceway.
@RyanJacksonElectrical
@RyanJacksonElectrical Рік тому
It isn't a raceway.
@jacobbotden5641
@jacobbotden5641 3 роки тому
I've thrown out many handfuls of those type S ties that loose their teeth immediately on first use just like the crappy ones.
@fdrestates
@fdrestates 3 роки тому
Hello Sir..thx for the video. I have a legitimate question. Where would I find in the code that a cable tray assembly must be identified for that particular application but does not have to be listed? Thank You! (Cable tray or any other material for that matter) Sidenote: I used to work in telecom years ago.. these are quite common in that industry and for outdoor cells all of the antennae transmission lines are supported by cable trays.. lots of temperature changes there
@RyanJacksonElectrical
@RyanJacksonElectrical 3 роки тому
The last sentence of 392.10
@LordVoltRod2c
@LordVoltRod2c 3 місяці тому
10:35 It will soon be raining snakes!
@felixsandoval486
@felixsandoval486 3 роки тому
Is there anything like "Commercial building" where conditions of maintenance and supervision ensure only qualified persons service the installed cable tray system? If so, could it be considered to install individual conductors on their cable trays?
@RyanJacksonElectrical
@RyanJacksonElectrical 3 роки тому
No, although I my opinion there should be. There were several proposals for the 2023 to change the concept to "restricted access locations," but those proposals failed. The proponent for these changes works at a national laboratory that has more stringent requirements than most "industrial" facilities but cannot use the allowances.
@felixsandoval486
@felixsandoval486 3 роки тому
@@RyanJacksonElectrical Ok. As usual Sir, great information, useful and clear. Thanks a lot. Already waiting for your next publication.
@chrishull1993
@chrishull1993 3 роки тому
Good content. Really enjoy the code updates. Only thing would be to grt a better mic
@RyanJacksonElectrical
@RyanJacksonElectrical 3 роки тому
Thanks for the feedback. The embarrassing truth on this video is that after I shot I realized that my mic was moved from where I normally put it. I had mopped the floor earlier and moved the mic stand, then didn't put it back. 😑
@chrishull1993
@chrishull1993 3 роки тому
Completely understandable. I just think that the use of a pop filter is underrated and the room echo is a little rough when I'm listening on my van speakers omw to work
@RyanJacksonElectrical
@RyanJacksonElectrical 3 роки тому
@@chrishull1993 I use a pop filter as well. In fact, you can see it in the video I did yesterday Thanks again for the feedback, I really do appreciate it.
Cable Tray, Three Phase Sockets & SWA Cable Install - Part 2
22:22
Artisan Electrics
Переглядів 73 тис.
😳 Домінація! ОГЛЯД БОЮ ЛОМАЧЕНКО - КАМБОСОС
04:06
Transformer configurations
28:59
Ryan Jackson
Переглядів 20 тис.
Cable tray size calculation method in simple way
8:37
Rashid iqubal
Переглядів 12 тис.
Working space in the 2020 NEC
22:18
Ryan Jackson
Переглядів 9 тис.
FLEXTRAY Installation- The Full Length Video
19:13
Summit Electric Supply
Переглядів 27 тис.
Article 724 Class 1 Circuits
13:03
Ryan Jackson
Переглядів 2 тис.
Cable Tray, Three Phase Sockets & SWA Cable Install - Part 1
14:26
Artisan Electrics
Переглядів 58 тис.
😳 Домінація! ОГЛЯД БОЮ ЛОМАЧЕНКО - КАМБОСОС
04:06