Thank you. We are waiting for the technician to come and fix other issues. I will surely give you a call as we have the same system that you showed. It is however running very noisily. We have 2 batteries and 6 panels.
@zparkergeco11 місяців тому
If your SNA 5000 serial no start with 228 and above, then use a straight comms cable between batt and inverter. Dip 1 is on
@landryulrichmakouana277Рік тому
Hi Anthony, nice video next time share a video on how to change settings.
@anthonymwambazi7390Рік тому
Noted
@mrbrooks5610 місяців тому
Same. Setup inverter on and battery is full, but no power to the house at night
@riaankoekemoer9035Рік тому
That is a 100ah battery, why does the info on the screen show 50ah.?
@ashleyisaaks96486 місяців тому
Please do some videos while doing installation
@anthonymwambazi73906 місяців тому
Noted
@keorapetsemasetle6373Рік тому
can i use a normal cat5e for communication between inverter and battery. i have the same equipment and im planning to energies tommorow
@anthonymwambazi7390Рік тому
Yes you can most certainly
@bradzlifeРік тому
Hi Anthony, question, is it not inverter 3,4 -> 5,4 battery. Also why does the settings show 50AH, is it not supposed to show the capacity of the battery?
@anthonymwambazi7390Рік тому
Hi there yes correct 3and 4 4snd 5 on the older Lux power the new stock has a sticker on the box that says straight cable as to the amp hour you have to tell the inverter what size battery it is if the function is disabled then it could be the battery manufacturers call to answer that one
@bradzlifeРік тому
@@anthonymwambazi7390 thank you 😀
@fanieduplessis2445Рік тому
@@anthonymwambazi7390 Hi Anthony - thanks for the video, however it causes some confusion - You mention 3&4 to 4&5 and as Bradz also mentioned should rather be 3&4 to 5&4, pin 3 on the battery goes to pin 5 on the inverter. Maybe add some text over the video that clarifies it. You also mention the protocol is 3&4 on the battery and 5&6 on the inverter???
@anthonymwambazi7390Рік тому
@@fanieduplessis2445 apologies to that will make a correction on it, with the older Lux power it was 3and 4 on the inverter side and 4 and 5 on the battery side now with the new stock in the country that comes with a notification on the box it's a straight cable you can buy from any computer shop
@fanieduplessis2445Рік тому
@@anthonymwambazi7390 Hi, yes, also find it to be 3&4 on the Inverter and then the 5&4 on the battery on the older Inverters.
@duncube9421Місяць тому
Hie sir, I have Greenwich up3648 in combination with five-star 5000 and canadian panels 400v panels x2 but problem is once the battery greenlights are full its beeps fault continuously until we switch it off. What could be the problem . I suspect that the two don't communicate as there is no communication cable between. How can it be corrected? Response will be appreciated.
@anthonymwambazi7390Місяць тому
Hello that looks like your charge settings need to be adjusted
@elisevangeffen7320Рік тому
Hi Anthony, the technicians have installed our Greenrich batteries under led acid????
@anthonymwambazi7390Рік тому
You can can contact me on 0823427946
@riaankoekemoer9035Рік тому
Do you know if the Ultra Energy Batteries is compatible with the luxpower inverters?
@anthonymwambazi7390Рік тому
No the ultra only has a bms for managing the cells charging and discharge parameters it does not have a communication protocol for the inverters would be glad if someone can make program for them to communicate I like those batteries as well
@riaankoekemoer9035Рік тому
@@anthonymwambazi7390 I did manage to get it to communicate somewhat with the inverter, but it only showed 2.9v on the inverter. So was almost there, but not close enough
@chrissimbarashetaderera8128Рік тому
My communication cable has all the pins. (There is no 3&4 or 4&5). Will that be a problem?.
@anthonymwambazi7390Рік тому
On the older Lux power you have to make the cable yourself or have it made at a computer shop, with the New version that's in the country now it's labeled on the box with a sticker use a straight like the one you have it will work all the best
@trevorbrown7357Рік тому
Hi i have been using my greenrich battery for about a month now...but 2 of the 6 battery indicator lights are off....why would that be?
@anthonymwambazi7390Рік тому
Hi there it's not charging fully or faulty battery which I highly doubt.let me know how your battery settings are as well.
@trevorbrown7357Рік тому
@@anthonymwambazi7390 by battery settings what do you mean and where can i check that for you?
@anthonymwambazi7390Рік тому
Give me call we can go through the settings together
@tibbydudeza11 місяців тому
The inverter will only topup the battery to what has been configured - my installer for example limited it to 80% of the installed capacity of the battery rather than filling it up to 100%.
@samueldudley5590Рік тому
Is this Inverter approved by the city of cape town?
@anthonymwambazi7390Рік тому
It's not approved it's an off grid inverter SNA5000, the one that's approved is the LXP
@zparkergecoРік тому
You can register the SNA5000 with solar panels with the CoCT as standby sseg, it's option 3 on the reg page
@Silverstream-74Рік тому
Hi, is your battery here juat 50ah?
@anthonymwambazi7390Рік тому
No it's a 100Ah the inverter was picking it up as 50ah I had to change the settings to 100ah
@myriadgreen1Рік тому
hi thanks and how i was told tgis is a hybrid inverter when i bought it is it a train smash?
@vincentjele3835Місяць тому
please help with customer for dongle wifi connection in the app
@anthonymwambazi7390Місяць тому
Hi can I help with the dongle connection is the customer struggling to bring it online give me a call to see were we can help
@ricardocloete5502Рік тому
Are you in JHB area
@anthonymwambazi7390Рік тому
Yes am based in Jhb
@ricardocloete5502Рік тому
@@anthonymwambazi7390 how can we get in touch as I need help with the same setup?