Welcome to my tutorial on how to fit an external power point. In this video I'm going to show you how I fit an outdoor socket step by step. If you like the content leave a like and please subscribe for more content like this.
My Shop: 🛒 My Shop -www.amazon.co.uk/shop/thediyguy
Check out the other videos on my channel and like and subscribe for more!
► BECOME A MEMBER OF THE DIY CLUB Click! 👇🏼
/ thediyguy1
► Get FULL access to the Discord Group and other perks!
Follow me on Instagram 👉 the_diy_guy_youtube
Thanks for watching The DIY Guy. My mission is to bring you the best Tips, Tutorials and Tools to help you learn and save money.
Please be advised that this is only a guide which is intended for informational, educational and entertainment purposes and The DIY Guy cannot accept responsibility for any work undertaken. Be safe and have fun! The Amazon links above are affiliate links and as an Amazon Associate I earn from qualifying purchases. I may earn a small commission if you purchase via the recommended links, however this will not cost you any extra.

КОМЕНТАРІ: 222
@walkerrobinson9614
@walkerrobinson9614 2 роки тому
An excellent teacher you are. Straight to the point, clear explanations, breaks things down. Better job than many teachers out there.
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
Thanks,im glad the videos help you.
@a.a.alexander6030
@a.a.alexander6030 4 дні тому
Thanks for this video. This is exactly the sort of job I want to do but have never tried. Thanks for the ABC style step by step guide. The tools, the method and the 'just how much of a job is it' - those are elements a lot of us look at as it may be a one-off job for many of us.
@TheDIYGuy1
@TheDIYGuy1 4 дні тому
Glad it was helpful!
@deborahsharpe6371
@deborahsharpe6371 3 роки тому
Very good description of how wire up an outdoor socket. Easy and clear. Thank you. As a diy beginner, I will enjoy following your channel.
@me1love2max
@me1love2max Рік тому
Nice one. Thank you. I need an outdoor double socket so I can get power to my greenhouse and so I can plus my mower in outside instead of going through a window or door. I was going to pay somebody to do it for me but this looks super simple... I've fitted electric sockets before but was a tad worried about moisture with an outdoor socket. This has eased my worries of doing it myself. Thanks 👍🏾 😁
@stanley325
@stanley325 3 місяці тому
Clear instructions, great explanations of why to do something, no ego (ain't I clever) just confidence boost to make me give it a go. Thanks
@hectorheath9742
@hectorheath9742 3 роки тому
Nice video, thanks. I have an aversion to knocking nails into masonry, it just don't seem right, but I know that's how the professionals do it. Also my experience of using the plastic clips is the plastic part eventually cracks and splits, so I use nylon 'P' clips and screws.
@ID29794
@ID29794 2 роки тому
Brilliant video really easy to follow and clear. Got a nice outside waterproof socket now installed👍🏻👌
@shendrew
@shendrew 3 роки тому
Very straight forward and to the point. Keep it up!
@leeroberts5668
@leeroberts5668 8 місяців тому
Brilliantly presented Really clear and concise and given me the confidence to tackle the job 👍🏻
@TheDIYGuy1
@TheDIYGuy1 8 місяців тому
Glad it helped
@peterchiu1979
@peterchiu1979 10 місяців тому
You made this look so easy and gave me confidence to try it! I hope I can locate the cable for my socket behind the back box but I assume that'll be easy
@TheDIYGuy1
@TheDIYGuy1 10 місяців тому
You can do it!
@alisdair9
@alisdair9 3 роки тому
Your video was very clear mate. Well done. Look forward to more just like it. Good luck 🤞🏻
@TheDIYGuy1
@TheDIYGuy1 3 роки тому
Thanks very much
@user-John666
@user-John666 7 місяців тому
Good job, well explained and although it isn’t exactly what I need to do, (I need to put one out to a decking area)it’s given me a good idea of what’s involved. Thanks
@TheDIYGuy1
@TheDIYGuy1 7 місяців тому
Glad it was helpful!
@dg-artist
@dg-artist 9 місяців тому
Very helpful video. Thanks for making it!🙂👍
@TheDIYGuy1
@TheDIYGuy1 9 місяців тому
Glad it was helpful!
@justjim4711
@justjim4711 3 роки тому
very informative and helpful thanks a lot
@Rajjjjjjjjjjjjjjjj
@Rajjjjjjjjjjjjjjjj 3 роки тому
Very informative ! Thanks a lot !
@ashvanbro9329
@ashvanbro9329 2 роки тому
Always love your vids brother
@PilbeamMP97
@PilbeamMP97 2 роки тому
Spot on thanks - exactly what I was looking for, well presented cheers 👍
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
Glad you found it useful 👍
@sianwilliams9550
@sianwilliams9550 6 місяців тому
That's awesome! Thank you! I thought it would be harder to get the electricity to it, but it's so simple! X x
@TheDIYGuy1
@TheDIYGuy1 6 місяців тому
Glad I could help!
@Tichx
@Tichx 7 місяців тому
Lovely video, nice and easy to follow.
@TheDIYGuy1
@TheDIYGuy1 7 місяців тому
Glad you liked it!
@jamescutting5589
@jamescutting5589 11 місяців тому
Great video 😊thanks always learning from you 👍
@steve11211
@steve11211 3 роки тому
If you drill from the outside in at a slight upward angle or inside out at a slight downward angle then no water can get inside. Its not relevant in your case but it should be said that if you come off a ring circuit you can only spur once so you cant spur off a spur. Another tip I would always put an outside socket connected to a fcu, think about this, its christmas day and hammering it down with rain, water has as it always will eventually got into that socket and has tripped the rcd, you have a freezer in the garage that you need but everytime you turn on the garage circuit it trips the rcd. If you have a fcu you can isolate the outside socket so you can deal with it at a later date. I would also run a bead of silicone over the top and sides of the socket just to reduce the chance of any water ingress. You could make life easier for yourself by stripping more of the outer sheathing, there is plenty of room in the socket and you will find it easier to terminate if you leave more of the single insulated conductors in the socket. pull the cable out, measure 3 fingers beyond the box then cut and strip back as much as possible. If you terminate only one cable into a socket it is really better to fold the end of the conductor over so it fills the terminal better which will ensure a better connection.. Finally as a minimum do a zs test and test your rcd to make sure it will trip, no point having an rcd if it wont trip in the required time.
@TheDIYGuy1
@TheDIYGuy1 3 роки тому
You certainly know your stuff my friend. If I were working in the house rather than the garage I would certainly tilt the drill bit. This for example is the type of thing I chose to leave out of the video due to length of the video if it were all added in. Believe me, some stuff mentioned in your comment was originally recorded but it's very difficult not to make a long and boring video when you add all of this stuff in. For those of you reading this comment. In the situation(my case) where your circuit is radial you don't need to worry about the maximum spur off(1). Steve however is correct in stating that you should check the RCD. Thanks
@gettingrounderroundthemidd9769
@gettingrounderroundthemidd9769 3 роки тому
Good extra tips to a good video 👍
@darknessdestroyer5524
@darknessdestroyer5524 2 роки тому
A FCU will reduce the load capacity of the socket to 13A, move the circuit over to the non RCD protected side of the CU and install a 20amp RCBO to achieve discrimination and therefore avoid tripping the RCD protected circuits 👍.
@JB-tc8el
@JB-tc8el Рік тому
@@darknessdestroyer5524 either you haven’t thought that through or you have little experience with UK domestic wiring.
@darknessdestroyer5524
@darknessdestroyer5524 Рік тому
@@JB-tc8el before I reveal my experience please enlighten me with the problem you see with my proposal.
@stevied1125
@stevied1125 10 місяців тому
fantastic video and properly done
@mattissakw
@mattissakw 3 роки тому
Great vid very helpful thankyou look forward to seeing more
@TheDIYGuy1
@TheDIYGuy1 3 роки тому
Thanks and welcome
@anthonyoconnell9389
@anthonyoconnell9389 3 роки тому
Great job very helpfull keep up the good work ☘️🥃💚👍
@intothemultiverse1033
@intothemultiverse1033 3 роки тому
Greg video mate. Keep up the good fight.
@Huntelaar13
@Huntelaar13 2 роки тому
Nice video, exactly what I needed. Cheers mate.
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
Your welcome, cheers
@asheu5511
@asheu5511 10 місяців тому
I am installing an external power socket and re-watched your excellent video. One thing, I'd like to check: what is the main reason for using the 15mm barrier pipe? Is it to protect the electric cable from the elements (inside the wall)? Would it matter much if I omitted using it? Many thanks for you channel. I particularly liked the video you did on installing lights in the loft. Kind regards...
@pauloroarty1799
@pauloroarty1799 2 роки тому
Brilliantly explained.I've Subscibed Thank you
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
Thanks, glad it helped you
@akgbm990
@akgbm990 2 місяці тому
thank you for all your help
@TheDIYGuy1
@TheDIYGuy1 2 місяці тому
You are welcome!
@adammunaf5661
@adammunaf5661 3 роки тому
Very helpful
@rosanadancel7225
@rosanadancel7225 Рік тому
Thank you, I lean more.
@Mrsprint90
@Mrsprint90 2 роки тому
Hi. I need to drill a hole from my living room to outside. It’s standard drywall then brick work. Would you just cable detect then drill straight though. Thanks
@paulpincher4998
@paulpincher4998 3 роки тому
Great video thanks very helpful
@TheDIYGuy1
@TheDIYGuy1 3 роки тому
Glad it helped you out!
@grahamrousell691
@grahamrousell691 Рік тому
Completely logical and efficient approach and excellent video. With your experience can you please clarify how the regs apply to this? I always understood all wiring in Kitchens, Bathrooms and outside had to be done by a NICEIC approved electrician and measurements taken of the new circuit. Are these reg requirements more relaxed now with the general installation of RCDs? Thank you
@TheDIYGuy1
@TheDIYGuy1 Рік тому
🙏thanks
@g41images70
@g41images70 11 місяців тому
Thanks for your great videos. I want to fit an outside socket for my hot tub. Is it advisable to run a spur from my internal socket to a fused spur point and thereafter wiring the external sockets to the fused spur?
@marcusregan4815
@marcusregan4815 3 роки тому
Good video, very clear
@TheDIYGuy1
@TheDIYGuy1 3 роки тому
Glad you found it useful
@ViniciusDellAglio
@ViniciusDellAglio 2 місяці тому
Awesome video! Thanks for sharing! Quick question: the socket has 2 earth entries, why did you use only one? Does it mean one gang will not be earthed? Thanks!
@misterjefferson6707
@misterjefferson6707 5 місяців тому
Excellent video. I have no DIY knowledge at all. I have a single socket outside - is it the same process to change from single to double as your indoor single to double socket change? Thanks!
@RossHbn
@RossHbn 2 роки тому
Thanks.
@chriswilkinson3260
@chriswilkinson3260 Рік тому
Oh it has helped mate spot on I have a outside socket on my new house I've just bought would I be right in saying I can bounce of that like you have in your garage and then put two double in my shed or would that overload it it's a new build I've got so one socket is on the house outside already it's only to run a dryer some led lights and maybe a spare in there for charging my drill up ect
@TheDIYGuy1
@TheDIYGuy1 Рік тому
You can spur off once on a ring circuit so it's best to check what circuit type you have first. The circuit in the video is a radial circuit.
@chriswilkinson3260
@chriswilkinson3260 Рік тому
@@TheDIYGuy1 thanks I don't know so I'll pay someone in that case then I know it's safe
@rayc1503
@rayc1503 Рік тому
Masterplug BG Outdoor Mains Socket Power Kit & RCD Protected Plug Weatherproof. (Google this). You can attach further sockets to this as long as the rcd plug socket is protecting all the cables.
@msmalik681
@msmalik681 2 роки тому
absolute legend
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
Cheers 👍
@ruthgolding7424
@ruthgolding7424 3 роки тому
hi mate how do i do it for double socket 1 either side of the house as all the power is on 1 side only
@sulemanyusufadam4315
@sulemanyusufadam4315 3 роки тому
Great video! I’m assuming that’s a radial and that you didn’t spur off a spur? 🤔 Personally I’d probably run it through an FCU first but not necessary I suppose. Often people don’t use conduit but it’s important to protect the cable.
@TheDIYGuy1
@TheDIYGuy1 3 роки тому
Hi, thanks. Yes this is a radial. Thanks for your input
@jakovfilimonov9698
@jakovfilimonov9698 5 місяців тому
Smashing! 👌
@kcomfortsystemshvac7060
@kcomfortsystemshvac7060 Рік тому
Good stuff,,,,mate appreciate,,,,👌
@TheDIYGuy1
@TheDIYGuy1 Рік тому
Anytime 👍
@chrisuk1287
@chrisuk1287 9 місяців тому
New subscriber so of course checking out your back catalogue, great content thanks, need to do this myself, it is always great to see a a video guiding you through it, yours is clear and concise so thank you :) Can I ask, we do have RCD protection at home, is there any good reason to still use an RCD protected outdoor box? Extra protection in some way? If there was an issue which would trip first the RCD in the outdoor socket or the house RCD? Like you there are lots of circuits on our setup at home protected by the 1 RCD so if the outdoor socket tripped first that of course would leave all the house circuits still live, any idea?
@VanyaYani
@VanyaYani 3 місяці тому
If I understood the question correctly, he's not using a separate RCD for the outdoor box. He's using the same RCD for both outdoor and indoor sockets. There's not RCD inside the socket. The RCD is the thing in the consumer unit. The RCD protects a fault in the thing plugged into the socket, so yeah, it makes sense to protect the outdoor socket as well, especially considering those are heavy duty things that are usually plugged into it. You could install several RCDs to protect different groups of consumers so that you would isolate the issue quicker and still have half of the house working.
@Brynben1
@Brynben1 5 місяців тому
Stop banging the tools and materials around 😂😂 Another well explained tutorial, thank you
@montystelevision3238
@montystelevision3238 3 роки тому
No peksy adverts in this video - subbed as a result.
@elbowtoe84
@elbowtoe84 3 місяці тому
A fab grand job
@TheDIYGuy1
@TheDIYGuy1 3 місяці тому
👍
@jtmac5745
@jtmac5745 11 днів тому
Top man👍
@TheDIYGuy1
@TheDIYGuy1 11 днів тому
🤙
@willappleton
@willappleton 9 місяців тому
hey i have a double waterproof socket that has two sets of 3 wires 1 on each plug... i want to convert it to a single timer based outdoor socket.. it should be ok to double up the wires as you said?? thanks now
@ViniciusDellAglio
@ViniciusDellAglio 2 місяці тому
One other question: could you have used wago connectors on the "source" wiring instead of double wiring the socket?
@3000shifty
@3000shifty 9 місяців тому
Thank you.
@TheDIYGuy1
@TheDIYGuy1 9 місяців тому
You're welcome!
@RajSidhux
@RajSidhux 2 роки тому
Hi, great and easy to follow video. Question: I'd like to install one of these in my back garden. Can you tell me would you need an electrical cert. for this? When do you need cert.s?
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
Thanks. Technically yes, outside is an area where electrical work should be undertaken by a qualified electrician. But it depends if you want to follow the rules or undertake it yourself, the decision remains yours. This video is purely an instructional video.
@RajSidhux
@RajSidhux 2 роки тому
@@TheDIYGuy1 I understand. I want to know if i do it myself, there are no laws against it right? And also, if i do it myself, could i then get a qualified electrician in to retro cert. them for me?
@rayc1503
@rayc1503 Рік тому
@@RajSidhux It's notifiable under a minor works cert. The only way it wouldn't be is if you fitted an RCD protected plug. It would have to have no fixed point of wiring inside the house. Like in this video.
@andyneary6448
@andyneary6448 Рік тому
Great video, thanks again. Is it safe to attach an outside plug and light to the corrugated metal sheeting I have around my shed? If it is safe to do so - Does the plug need to be fitted to a flat surface? If yes, then presumably I can attach it to a piece of ply and then screw the ply to the corrugated sheet.
@TheDIYGuy1
@TheDIYGuy1 Рік тому
I'd go for a flat surface for sure 👍
@rayc1503
@rayc1503 Рік тому
Ip rated 20mm Cable gland and some 2.5mm weatherproof arctic cable coming out the bottom through the wall in conduit and fit it to a 13 amp rcd plug.
@rosivison6526
@rosivison6526 10 місяців тому
Nice video and very easy to follow. Do you have a ring or radial circuit? I see you are taking the power off the socket that only has one set of wiring in it? Is this the end of the circuit or is it already a spur?
@TheDIYGuy1
@TheDIYGuy1 10 місяців тому
Hi. This is a radial circuit. Thanks
@WJCTechyman
@WJCTechyman Рік тому
I find it interesting your boxes don't require the non-metallic (Twin and Earth/Bare) to be clamped in place inside the box like we have in Canada. I also find it interesting that you put a sleeve over your grounding/earth conductor.
@acelectricalsecurity
@acelectricalsecurity Рік тому
We stopped having bare earth's probably before the 60's
@CS-rf6jq
@CS-rf6jq 10 місяців тому
I. could. do. this. Thanks for making these videos without sounding like an arrogant know it all (except at 5:08 lol ;) ) and keeping the videos gibberish free.
@robertpeters8531
@robertpeters8531 2 роки тому
Thanks
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
Your welcome
@stuartcraigon2003
@stuartcraigon2003 7 місяців тому
DOH! As soon as you drill that drain hole its not ip66 rated anymore. Youll see on the instructions or the writing on the back box that it clearly says that.
@tj9382
@tj9382 8 днів тому
But he threw them away 😂😂😂
@samanthastewart8849
@samanthastewart8849 6 місяців тому
Hi I have an outdoor plug but it's at the bottom of my garden in a shed and it's an old plug that's always been on as it was for our oil boiler but it has stopped working what do I do?
@clitherowkid
@clitherowkid 2 роки тому
Is that a soured socket and did you use 1.5 or 2.5 T & E ? Great video, I’m going to install one myself.
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
Thanks. It is a spur from a radial circuit. 2.5t&e. See this video which may help to explain further ukposts.info/have/v-deo/qpWAl6qamZVmxYk.html
@tomedwards4489
@tomedwards4489 Рік тому
Whats the Ze,zs,r1+r2, polarity and insulation resistance.was it a ring main if so did you calculate your readings of the ring r1x1.66 for the 1.5 cpc expected end to end result? Or was it x2.5 because you had a 1mm cpc in that old twin? On the rcd did it test OK 1x 5x. Type Ac rcd in the fuse board is that going to be OK. Just in case it don't comply have we checked the bonding.just some of the cheeks a competent person should be doing.
@KristopherPorter1986
@KristopherPorter1986 2 роки тому
Are the wires between the originally installed socket loops more sturdy/capable than the wire you use for a spur?
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
Hi. The wire is exactly the same 2.5 t&e. Cheers
@Ramskill85
@Ramskill85 Місяць тому
I’m thinking of doing this myself. I’m just wondering if this needs to be signed off by an electrician? Don’t really want the hassle when coming to sell the house in the future.
@Danieltammadge
@Danieltammadge 20 днів тому
In the uk don’t you need to get new outside sockets or wiring of that case signed off by a P certified installer. Or you void your house insurance and face fines etc?
@harrymonk6909
@harrymonk6909 3 роки тому
I'm looking to put up an outside light, I've run 1.5 into it and a plug on the other end then just plugged it into my outside socket, I'd rather it be run directly into a switch inside, can you do a video for that please?
@TheDIYGuy1
@TheDIYGuy1 3 роки тому
Hi, i will see what i can do for you. thanks for reaching out
@johnpaulcameron2162
@johnpaulcameron2162 3 роки тому
Brown in common blue in L1 and earth connector blocked behind light switch
@nitinkoli5nk
@nitinkoli5nk 3 роки тому
Hi the socket box is 13 A do we have to use a socket fuse spur with 13 A fuse or we wire directly as you have show in this video?
@bradreeve6233
@bradreeve6233 3 роки тому
Just come straight out the socket either way doesn’t matter really
@nitinkoli5nk
@nitinkoli5nk 3 роки тому
@@bradreeve6233 Thanks for info.
@badgerburns521
@badgerburns521 7 місяців тому
really good instructional video but could you amend the description text with a list of the tools and equipment needed please?
@TheDIYGuy1
@TheDIYGuy1 6 місяців тому
Thanks
@jigneshmistry2341
@jigneshmistry2341 Рік тому
Legend
@TheDIYGuy1
@TheDIYGuy1 Рік тому
👍
@TheMartyJD
@TheMartyJD Рік тому
Was going to do something similar, but the only socket I could find inside was already a spur and therefore was looking for somewhere else to connect to. I see that you've done exactly that (assuming it is a ring rather than radial). Is there any issue of spurring off an existing spur?
@TheDIYGuy1
@TheDIYGuy1 Рік тому
This is a radial circuit on the video. You can only spur off once on a ring.
@tabraham1992
@tabraham1992 Рік тому
@@TheDIYGuy1 the radial you spurred off was the end of line, so all you’ve done is extend the radial
@rayc1503
@rayc1503 Рік тому
If you can put a 13a fused connection unit before the existing spur then run a new cable to both it and the new point. Then the 2.5mm t&e cable itself is protected from overload. Better still buy an outdoor socket which has an rcd type plug. The fuse and rcd plug should trip incase of fault, thus protecting the existing cable.
@markwelsh9068
@markwelsh9068 Рік тому
Here's my problem: Where I need to install the outside socket is on a wall which, on the other side, is a landing with no sockets. The nearest socket is in a bedroom and, to get there from the inside wall where the outside socket is placed on the other side, I'd have to run cabling up and down and around a whole bunch of walls or lift up carpets and flooring to run underneath. The alternative would be, I guess, to, somehow, run directly from the main switch/consumer unit which is located downstairs (but on the same wall as the outside socket) and then it's a matter of, somehow, running cable from the consumer unit (all switches are used however) but how to run the cable up those stairs, I have no idea. Any suggestions? Thanks.
@paulbowmer9507
@paulbowmer9507 3 місяці тому
Move house?😊
@flashmg89
@flashmg89 3 місяці тому
Come out of house where convenient into outdoor junction box and then run cable along outside wall in trunking and enter socket box via side knockout?
@jonthecarpenter8093
@jonthecarpenter8093 11 місяців тому
So you have spured off a spur? Is there a fused spur before your first original outlet?
@TheDIYGuy1
@TheDIYGuy1 11 місяців тому
Nope, radial circuit.
@ConradWilliams400m
@ConradWilliams400m Рік тому
Nice and simple you don’t need a lot of tools . Hahahahahahaha😂 brill video
@TheDIYGuy1
@TheDIYGuy1 Рік тому
Absolutely, thanks 👍
@andrewappleyard796
@andrewappleyard796 Рік тому
I oready have a outside light , could you use a terminal strip ( not use on the amp needed ) use a terminal strip inside a waterproof junction box to split the wire intoo 2 lights off the one wire Sorry might sound like a stupid question but I'd rather ask then find out the hard way , tia
@rayc1503
@rayc1503 Рік тому
As long as the cable isn't overloaded. Let's say 1.0mm twin and earth on 2 400w flood lights off an existing 6A mini circuit breaker, it should be Ok. Better if it's fused from inside (3A for loads under 690 Watts)
@apocreg11
@apocreg11 Рік тому
So I have a ring circuit and I have taken a spur to a double outside plug off a single plug, then a SWA to a second single socket off that double socket. So 4 sockets in all off one spur. Given all 13 amp this should be ok?! Despite you normally saying only one spur off a ring circuit plug?
@TheDIYGuy1
@TheDIYGuy1 Рік тому
Hi. Unfortunately this isn't advisable and I wouldnt feel comfortable with it. This is due to the load on the cable.
@williamhastings4491
@williamhastings4491 Рік тому
First Class
@TheDIYGuy1
@TheDIYGuy1 Рік тому
Cheers 😊
@terex1983
@terex1983 3 роки тому
Good DIY video, some nice detail with the protection of cables through walls for example but for anyone that may attempt to follow it: Check the inside face of the wall for services not just the outside with those detection devices, they will not penetrate a cavity wall. Also, electrical cables can/should be run directly vertically and/or horizontally in any direction from any accessories (switches and sockets etc). PROVE that the circuit is dead before working on it - don't just rely on the fact it says it's off at the Consumer unit as it may be mis-lablled or fed from a different circuit entirely. TEST your modification afterwards. Plug in testers are a minimum as you will not notice a disconnected earth(CPC) conductor. As this is an outside socket has a high potential for faults.
@deansharpe6527
@deansharpe6527 Рік тому
I’m going to be doing this using 2.5 my flex, I know this is probably a daft question but should I be using a 13amp plug?
@TheDIYGuy1
@TheDIYGuy1 Рік тому
👍
@MrMedicalUK
@MrMedicalUK Рік тому
Can I run conduit under the soil along my path down to my pool and fit this to a solid wooden fence post?
@MrMedicalUK
@MrMedicalUK Рік тому
About 10 metres
@MrMedicalUK
@MrMedicalUK Рік тому
Also where did you find 15mm solid Conduit? I can only find flexi at 15mm Wanted to run solid from the outside wall into the ground then flexi along the ground
@TheDIYGuy1
@TheDIYGuy1 Рік тому
Hi. I would advise using armoured cable for underground use.
@phill3144
@phill3144 7 місяців тому
Is this not a spur off a spur, and no isolation point after the internal wiring.
@TheDIYGuy1
@TheDIYGuy1 7 місяців тому
No, it’s a radial circuit
@barry10ish
@barry10ish Рік тому
Have you done a video on how to wire a shed ?
@TheDIYGuy1
@TheDIYGuy1 Рік тому
Not as yet but maybe in the future 🙂
@elbowtoe84
@elbowtoe84 3 місяці тому
@hughwilliams5995
@hughwilliams5995 9 місяців тому
I see below that this circuit has been tapped off a radial rather than a spur. Many people will be tapping from ring mains, and it's important that they don't do this off already existing spurs. Perhaps this should have been included, especially as it means that they'll be attaching 3 lots of connections into the back of the socket (two for the ring and one for the outside spur) which can be hard to do given the inflexibility of modern gauge wiring, and more likely to end with loose connections from having three wires in each terminal.
@TheDIYGuy1
@TheDIYGuy1 9 місяців тому
A fair point that. This was my first UKposts video. If I were to make it now(nearly 3 years later) I would have included that point
@george9710
@george9710 Рік тому
Nice video. IMO pex is a total overkill and you can easily seal the hole with silicone, mastic, etc. Since the electrics are attached to the wall, you will get no movement and mechanical degradation of the protective sleeve. That said it's a really nice touch and makes things very serviceable. One trick to save yourself a lot of potential problems, don't pre drill the box. Level it on the wall, and use some duct tape to hold it (temporarily). Drill though the box and into the wall. That way you know it's all lined up and you'll never have to deal with poor placement of plugs. In case this is not clear, you need to turn the hammer function off when you drill the plastic. ABS plastic is strong but you can still crack it. Also a masonry bit will technically rub the plastic until it sort of melts away rather than drill it but it absolutely works. Once you have a hole in the wall, depending on the plugs you use, you may even be able to insert them though the box into the wall ( with the screw slightly attached). Small size Rawplugs work like this but Fisher doesn't so you'll need to move the box out of the way for a bit.
@abdulmaajid3030
@abdulmaajid3030 3 роки тому
Because it’s ip66 if you drill the drain whole would it still be ip66
@entercybotron6154
@entercybotron6154 2 роки тому
I've watch other video's and they say NO it won't be after you drill it out
@chaos.corner
@chaos.corner 6 місяців тому
IP66 is waterproof. Unless you are mounting it to a submarine, you probably are better off avoiding condensation problems.
@rayyg2508
@rayyg2508 2 роки тому
What size cable was used?
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
2.5mm twin and earth.
@lllCostalll
@lllCostalll 5 місяців тому
what size electrical cable
@TheDIYGuy1
@TheDIYGuy1 5 місяців тому
2.5mm t&e
@thomasparsons4999
@thomasparsons4999 3 роки тому
I’ve got brown,blue and back wires is that normal ?
@kevinwhite2380
@kevinwhite2380 3 роки тому
Not normal! Get a Qualified Electrician if you don't know what what cores do what? #Blue_Wizzard
@malachydixon9187
@malachydixon9187 Рік тому
Brown and red is live black and blue is neutral and earth is always yellow and green
@kerryman9589
@kerryman9589 3 роки тому
How much mastic do I need and were can I get it
@spencerwilton5831
@spencerwilton5831 3 роки тому
Minimum ten gallons. Only available from a little stall in Bagdad market, turn left at the knock off Nike seller and if you pass the guy selling mosque shaped alarm clocks you have gone too far.
@charliehead94
@charliehead94 2 місяці тому
Surprised you did not run the power into a fused spur internally then to run it through the wall to the socket.
@hectorheath9742
@hectorheath9742 3 роки тому
Isn't that running a spur from a spur?
@TheDIYGuy1
@TheDIYGuy1 3 роки тому
Radial circuit not ring main so it's within regulations
@Mike_5
@Mike_5 3 роки тому
Virgin Media teach you to drill from the inside and push all your weight on the drill so it comes out the other side like DumDum bullet hole and busts all the brick face out ...
@leebrailsford251
@leebrailsford251 4 місяці тому
Your newest videos are ssssoooooo much better than this. Thank god.
@TheDIYGuy1
@TheDIYGuy1 4 місяці тому
Hah your right!
@adamdean4322
@adamdean4322 Рік тому
Should never be done by Diyer though. Unless you can test the circuit how do you know it’s safe.
@TheDIYGuy1
@TheDIYGuy1 Рік тому
It’s very simple for a DIY’er to make safe. Thanks
@LeapOfFaith121
@LeapOfFaith121 2 роки тому
Where abouts are you based?
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
Norwich, UK
@LeapOfFaith121
@LeapOfFaith121 2 роки тому
@@TheDIYGuy1 I thought I recognised that accent. Great videos. 👍
@TheDIYGuy1
@TheDIYGuy1 2 роки тому
@@LeapOfFaith121 haha! Thanks
@andyb7507
@andyb7507 Рік тому
Basically you need the contents of B&Q to do this job
@andrewashdown3541
@andrewashdown3541 9 місяців тому
Why not just plug the thing into an existing internal socket?
@peterclarke1962
@peterclarke1962 7 місяців тому
Very good video but shouldn't you put silicone around the conduit though the wall on the outside as well as the inside.
@TheDIYGuy1
@TheDIYGuy1 7 місяців тому
Thanks, I did 👍
@chaos.corner
@chaos.corner 6 місяців тому
@@TheDIYGuy1Not from what we saw at 7:04. You sealed the box to the pipe but not the box to the wall or the pipe to the wall.
@stevoc9930
@stevoc9930 3 роки тому
Surely you mean an external Socket?
How to Install the Easiest Outdoor Socket
15:22
Proper DIY
Переглядів 737 тис.
How to Install an Outside Tap - Quick and Easy Method Anyone Can Do
13:32
How to Install Outdoor Outlet from Indoor Outlet
15:40
Kyler's Studio
Переглядів 168 тис.
How to install an Outside Socket with a Fused Switch Spur (Safely)
21:44
DIY Outdoor Outlet - How to install an outlet in your garden or yard
5:57
BusyDadsWorkshop
Переглядів 230 тис.
5 Mistakes Everyone Makes Changing Sockets ❌
11:44
Artisan Electrics
Переглядів 452 тис.
AMAZING TOOLS YOU SHOULD KNOW ABOUT
16:11
TechZone
Переглядів 73 тис.
How To Add An Outdoor GFCI Outlet | Easy DIY In One Hour!
7:44
April Wilkerson
Переглядів 458 тис.