Commercial Electrical Fault Finding
33:50
4 місяці тому
My Goals as an Electrician in 2024
11:40
4 місяці тому
How to BREAK a 250A Circuit Breaker
34:12
4 місяці тому
Re-wiring a BURNT OUT building
34:38
5 місяців тому
Tado Smart Thermostat V3+ Installation
33:42
5 місяців тому
Re-wiring MELTED Electrical Supplies
31:58
5 місяців тому
I’m Back.
4:25
5 місяців тому
Calibrating your Electrical Tester
10:52
7 місяців тому
Connecting up a Three Phase Distribution Board
19:55
3 Phase Surge Protection Installation
19:54
10 місяців тому
Carpark Street Lighting Fault Find
38:44
11 місяців тому
Commercial Distribution Board Second Fix
11:32
11 місяців тому
Earth Fault Loop Impedance Testing - ZS
9:32
11 місяців тому
Commercial EV Charger Testing
32:17
Low Voltage Cable Spiking
11:35
On-Site Electrical Validations
34:27
КОМЕНТАРІ
@CreepyCrawly-xy1iw
@CreepyCrawly-xy1iw 3 години тому
There's no earth connection and the supply live fuse has been removed, but as it's ac current, doesn't the neutral act like a "live" wire. Near the end of the video when connecting to the incoming mains supply "neutral" connection, is it a neutral at a possible live 230V. These are just questions, idk, just curious.
@connor4891
@connor4891 11 годин тому
No wire strippers
@effervescence5664
@effervescence5664 13 годин тому
I have already been C2'ing installations during EICR's because RCD's aren't bidirectional when protecting solar/ wind power which have burnt out on the solenoid. Initially it was because if the test button doesn't work = C2 but after Mark Allisons video last year I've been amending my comments to list "needs a bidirectional rcd". Biggest issue being that not every manufacturer is making it easy to find out and not every technical helpline has someone at the end of it that knows if their product is or isn't. Hats off to the chap on Efixx comments the other day that told me to phone M2, their technical helpline is one of the best for knowledge on their products I've had to deal with. Sadly the latest EICR with an RCD issue on solar I C2'd has gone radio silent, possibly due to the amendment dropping a couple days later and realising they potentially have thousands of installs nation wide which they're now liable for the design and rectification of.
@nathanbaldini8622
@nathanbaldini8622 14 годин тому
Mike Page - Legend 💪
@taibrook5426
@taibrook5426 15 годин тому
Look at you Mr black hat. Yes bro 💪
@mfr58
@mfr58 15 годин тому
I asked engineers about this way back at the start of solar and everyone seemed to think it wasn't a problem. How come the mighty IET only now have got their arse in gear? Are they going to pay to put all the installs right?
@guffermeister
@guffermeister 2 години тому
Because the IET is usually a decade behind the real world - by their own admission. With solar on it's own it probably isn't as much, but with battery storage now becoing popular and island mode now appearing it problably is starting to be more of an issue. We've had this with the first couple of goes at AFDD's with the stupid lookup likelyhood of lightning which thankfully got quickly abandoned, to the then EV charing points about having PEN protection and all that
@bigissue9179
@bigissue9179 16 годин тому
EVEN A REWIRABLE FUSE IS BIDIRECTIONAL LOAD OF BOLLOCKS
@MichaelAnderson436
@MichaelAnderson436 16 годин тому
Glad you're back boss!
@walseee
@walseee 16 годин тому
So if you don’t use a Bi-directional device on solar installs for example it can damage the MCB, so the manufacturers have put into their warranty’s that if they break because of this it’s not their problem?
@laujovo5368
@laujovo5368 17 годин тому
The unidirectionality of "usual" devices only comes from the fact that most RCBO etc. in the UK are based on a microcontroller, right? Reason for my question is I'm based in Germany and we are told that it absolutely doesn'T matter how you connect RCDs, RCBOs etc. and they do not have any markings on them whatsoever, whether one terminal is the load side and one the grid side of it (they are solely based on the electro-magnetic and bimetallic principle). Would love to hear your comment on it! :) Oh and by the way get well! Wish you the best!
@wiedapp
@wiedapp 12 годин тому
As long as you're using a RCD type A that's correct. With type B RCD it's a bit different, because of the electronics inside.
@electrician247
@electrician247 17 годин тому
Awesome stuff Mike
@awsometomable
@awsometomable 18 годин тому
Good to see you bud!
@sergiofernandez3725
@sergiofernandez3725 19 годин тому
Good to see you back on UKposts Mike. No need to apologise for lack of content, your true fans will understand.
@residualcurrent
@residualcurrent 19 годин тому
Thanks bro ❤️
@Richardincancale
@Richardincancale 19 годин тому
Bi-directional RCBOs sounds like a good idea on circuits with microgeneration but… please correct me if I’m wrong …aren’t most RCBOs inherently bi-directional? They typically rely on a bimetallic strip for light overload, and magnetic coil for big overloads, plus a toroidal transformer carrying line and neutral with a detection coil to trip in case of an imbalance. I don’t see why any of these components would be directional? Is it really just a labelling issue?
@residualcurrent
@residualcurrent 19 годин тому
I believe uni-directional RCBOs if powered from the load side have the potential for the solenoid and RCD logic board to burn out as they remain energised, proteus did a good video explaining it, the bi-directional RCBO’s have an additional contact internally. I believe that this same level of protection can be achieved with and MCB and RCCB both of which have generally been bi-directional for years, do check specs though, verso have a little PV board that does exactly this 🤝🏼
@GraemeMcKeague
@GraemeMcKeague 18 годин тому
@@residualcurrent But if the microgeneration (inverter) detects no grid, It shuts down almost instantly and doesn't generate any power, to "back feed" a RCBO. Having a Bisdirectional would leave an extra level of safety especially if its just a drop in replacement rcbo, on any future installs.
@retrozmachine1189
@retrozmachine1189 17 годин тому
I'm no expert in these matters, not by any means. I'm just an older bloke that had little to do with RCDs having worked in the '80s. It's about 2 things from what I can tell. The manual test button being held in for an extended period, which is the main concern, and devices that do not switch the neutral. The test button part is obvious, but the neutral part may not be. From what I've read about the ICs used etc no RCD latches the earth fault state - ie once the imbalance through the CT ceases the coil current is reduced back to pre-trip condition (there is always minor current through the trip coil with electronic types). This is backed up by actually experimenting with several 'directional' RCD/RCBOs available in Australia, the trip is repeatedly fired with supply on the wrong side and you can hear it but once the imbalance stops so does the firing. Of course, there may well be an RCD out there that does latch the condition and does place high current through the coil essentially until it burns out. Imagine you have a non-neutral switching electronic RCD, a N/E fault downstream of the RCD, and supply on the wrong side which will keep the electronics working post trip. The RCD will trip but imbalance potentially remains present due to the N/E fault, so the coil is left with high current indefinitely. A magnetic RCD would have a similar issue with N/E faults since the coil is powered by the CT directly but I'm not sure if it would cause a problem since it's only trying to disrupt the hold-in magnet rather than whacking the heck out of the trip mechanism like electronics do. Ensuring the use of neutral switching RCDs will address N/E faults, switching the test circuit addresses excessively long presses of the test button. Happy for anyone to make any comments about the above to explain why it may be incorrect.
@leexgx
@leexgx 7 годин тому
@@GraemeMcKeague the issue is when a solar panel system is wired into a consumer unit, They typically wire the load side of the RCBO from the solar inverter so are always receiving load on the load side of the circuit breaker (it’s always back feeding when inverter is making power) so it might destroy the RCBO circuitry if it’s not bi-directional Same would happen if using ac couple battery storage system when it is discharging the power to the house it will be backfeeding via the load side of the RCBO
@dukeycarrow
@dukeycarrow 19 годин тому
RETURN OF THE MAC 🎶 good to see you and your knowledge back lad 👌
@residualcurrent
@residualcurrent 19 годин тому
Haha very kind! It’s good to be back 🤝🏼
@Jake_Baker_Electrician1997
@Jake_Baker_Electrician1997 20 годин тому
Yes Mike! Been waiting for one of your videos! Hope all is well dude 👍🏼
@residualcurrent
@residualcurrent 19 годин тому
Thanks man, I’m all good!
@Jake_Baker_Electrician1997
@Jake_Baker_Electrician1997 18 годин тому
@@residualcurrent🙏
@residualcurrent
@residualcurrent 20 годин тому
Comment on the BS7671:2018 A3 DPC - electrical.theiet.org/bs-7671/updates-to-18th-edition/ BEAMA Technical Bulletin - www.beama.org.uk/resourceLibrary/beama-technical-bulletin---connection-of-unidirectional-and-bidirectional-protective-devices.html
@Cpt_Dave
@Cpt_Dave 4 дні тому
The double edged Knipex one has 2 different functions. Upper blade is for cutting isolation, making the cable smaller. Lower one is for the actual cut.
@ilovetitanium4136
@ilovetitanium4136 6 днів тому
Not sure a hex key in the Knipex shears is the best way. Hex bit in a ratchet might be better and won't ruin the cutters.
@SpikesMavic
@SpikesMavic 8 днів тому
But if the test Spikes are into dry ground, what will that measure ?
@andrewwhite3793
@andrewwhite3793 11 днів тому
Is the time clock a normal one or an Astro clock ? reason I ask I had a job where the customer spent daft money getting the main contractor out 5-6 times a year to suit the seasons and summer/winter times. I fitted an Astor clock that shadows the area you are in sunset and sunrise time plus it automatically changes the summer winter times
@retrun813
@retrun813 12 днів тому
Hey Mike its been nearly 6 months. Are you planning any video of reviewing this system over time? currently i am on a buy and cannot decide between these and Meross one. Take care!
@sajeevipiumika4033
@sajeevipiumika4033 12 днів тому
Is this for TT system?
@ceangasrevenge
@ceangasrevenge 12 днів тому
Youse guys don't do the tighten loosen wiggle tighten torque method ?
@dorianwylie9000
@dorianwylie9000 12 днів тому
I find it handy to have one not only for bonding but to go round all the metal faceplates if any and touch off them to see if the earth is continuous
@circuitbreaker1434
@circuitbreaker1434 13 днів тому
you may want to look into the DS203NC series from ABB 😅
@samuelanderson1338
@samuelanderson1338 17 днів тому
That’s a Del Roy type job
@chrismason3341
@chrismason3341 23 дні тому
Dno or supplier still not been out to reseal?
@chrismason3341
@chrismason3341 23 дні тому
The inspection cover is pointless as the dno have only left you with a tt as its a temporary supply and will be redundant when the permanent supply is re installed.Secondly you dont want to be kneeling on that joint, your likely to over stress the old lead causing premature failure of the joint or cause a flash over
@atharsabir5043
@atharsabir5043 23 дні тому
During connection there is 110 v appearing in earth line
@jamesgee474
@jamesgee474 25 днів тому
Always connect neutral 1st when making it off into live cutout
@chas3997
@chas3997 28 днів тому
2 errors here don’t run the earth in front of tails ( also don’t touch tails) 1667 is the maximum for additional protection. But 100ma time delayed ADS is a maximum of 500ohms. You may have to cover both ADS and Additional protection depending on safety assessment.
@jackwolf121
@jackwolf121 29 днів тому
Interesting info from Google “A bubble level has a measuring accuracy of 0.5 mm/meter in both normal and reverse positions. As we have seen, a digital level has an accuracy of +/- 0.05 degrees from 0-90 degrees and +/- 0.2 degrees from 1-89 degrees. So there is almost no difference between them, less than would ever be noticeable by the human eye”
@seanjay886
@seanjay886 Місяць тому
That previously intro was absolute 🔥I loved the drama and suspense it created. Not only is your sparkie game on point. Your production and editing is mint mate. 10/10 would recommend
@tonywatson1412
@tonywatson1412 Місяць тому
At the end , your neutrals and earths , connect them together. but WE know what you mean....!!!
@tonywatson1412
@tonywatson1412 Місяць тому
See so many electricans with gloves on...is there really any need for it...? wouldnt like the loss of feel
@iancoles1349
@iancoles1349 Місяць тому
U will damage the edges on u brand new knipex shears doin that Deff a code v
@barghtubereza
@barghtubereza Місяць тому
Hi What is the reference of 0.05ohm for bonding wire?
@Interdiction
@Interdiction Місяць тому
Scrap thieves dream .
@pozinglikebigemosoundcloud4767
@pozinglikebigemosoundcloud4767 Місяць тому
Where’s new video bro…….. We miss u already