@azadsmail8
@azadsmail8 2 дні тому
Hi nice vid but I noticed that the highest reading is PEFC 950.3 this one should be doubled and recorded not the PSCC am I right? THANKS
@alanmarriott9216
@alanmarriott9216 14 днів тому
How did you know where on former the 2nd mark had to go to bend?
@mykegyver7610
@mykegyver7610 5 місяців тому
You should voice an animated movie character. (I am not joking)
@captainkidd1811
@captainkidd1811 5 місяців тому
Art
@nevermind824
@nevermind824 6 місяців тому
Nice tip about scoring the conduit for the thread line.
@headsup4sparkies
@headsup4sparkies 5 місяців тому
Works for me 😀
@SigmaPotato327
@SigmaPotato327 7 місяців тому
very nice
@lewiswebb1843
@lewiswebb1843 8 місяців тому
Thanks mate, got my am2s this Monday and this is spot on 👍🏻
@pvegod1484
@pvegod1484 Місяць тому
Did you pass it mate? I’ve got mine in a couple week bricking it
@lewiswebb1843
@lewiswebb1843 Місяць тому
Yea passed 1st time mate 👍🏻 I’ll be honest, if your here looking up videos to pass then you’ll probably be one of the guys that will pass either 1st time or on a return attempt 👍🏻 good luck 🤞🏻
@jonathan_ansell
@jonathan_ansell 8 місяців тому
christ ! - kill the music and the avatar... then you've got a great video !
@monikacieminska5380
@monikacieminska5380 8 місяців тому
Fantastic video. Thank you 👌😀
@headsup4sparkies
@headsup4sparkies 8 місяців тому
Glad you found this useful 😀
@user-cs9ch8ey9k
@user-cs9ch8ey9k 10 місяців тому
Excellent video as always, thank you.
@headsup4sparkies
@headsup4sparkies 9 місяців тому
🙏 Thank you .. hope it has helped ..
@anowerhsahed1091
@anowerhsahed1091 10 місяців тому
Very good work
@Rossisearle
@Rossisearle 11 місяців тому
helpful but surely that Zdb your say is Ze because the is the 3 phase dno supply? is zdb would be at 2nd or 3nd distribution circuit ? ASKING
@headsup4sparkies
@headsup4sparkies 11 місяців тому
Hi … If the board is at the origin of supply - then Zdb and Ze would be the same. Ze recorded on certificate and Zdb recorded on schedule of test results. If there is a sub main between the origin and the board under test .. then Zdb is measured at board with earth disconnected - and Ze from origin recorded on the certificate.
@headsup4sparkies
@headsup4sparkies 11 місяців тому
The distribution board at the origin supplying the sub main, would also record this supply’s Zs on on it’s own schedule of test results, taken in the same manner but with the earth connected.
@headsup4sparkies
@headsup4sparkies 11 місяців тому
The board in the video is assumed not to be at the origin of supply … Hope this helps 👍🏻
@Rossisearle
@Rossisearle 11 місяців тому
​@@headsup4sparkies right... So like a three phase distribution circuit?
@headsup4sparkies
@headsup4sparkies 11 місяців тому
Yes … we call them “Sub-Mains” when we distribute the supplies from DNO to distribution boards… and the circuits from there are “final sub-circuits” supplying current using equipment without further distribution.
@glenngray3351
@glenngray3351 11 місяців тому
Hi I am having a few issues on identifying the types of wiring and reference method on the Generic schedule of circuit details. Can help or advise please?
@headsup4sparkies
@headsup4sparkies 11 місяців тому
This can be simple - or complex, depending on the variety of methods employed on the route. You can select the most used method on the route / the method with most detrimental effect .. or so on. The inspector should use engineering judgement to decide … this link to IET - Supporting BS7671 Appendix 4 .. might help electrical.theiet.org/media/1617/appendix-4-of-bs-7671.pdf
@detroutspinners9933
@detroutspinners9933 Рік тому
Brilliant video, really appreciate the time taken to animate the test sequences as well. Helps to visualise what you’re doing so much better!
@headsup4sparkies
@headsup4sparkies Рік тому
Thank you 🙏.., I’m glad you found this helpful 😀
@sports872
@sports872 Рік тому
Enjoyed the video. Would like to see more testing videos if possible.
@headsup4sparkies
@headsup4sparkies Рік тому
More to come!
@brianhewitt8618
@brianhewitt8618 Рік тому
excellent 👍
@headsup4sparkies
@headsup4sparkies Рік тому
Thank you! Cheers!
@ronnymoscoso1212
@ronnymoscoso1212 Рік тому
Cual es el modelo y la marca de la dobladora
@headsup4sparkies
@headsup4sparkies Рік тому
www.google.co.uk/search?q=hilmor+pipe+bender&ie=UTF-8&oe=UTF-8&hl=en-us&client=safari#imgrc=D9SEkwT73edTWM
@mario.elektryk
@mario.elektryk Рік тому
Very detailed video. 👌 Much appreciated.
@alanmarriott9216
@alanmarriott9216 Рік тому
Great video but how do you know when doing the 1st and 2nd bends on set where bend starts on former please!?
@headsup4sparkies
@headsup4sparkies Рік тому
When the conduit is resting in the former, the bend will be at the point where the conduit and former separate (underneath) … I generally place my little finger underneath to “feel” where that point is - and try to get the mark in the conduit at that point.. However - you don’t have to get it exactly right, as you can simply adjust the depth of the set. To add depth, put a little more in each bend. To decrease the depth, take a little out of each bend. Making sure to adjust the existing bend and NOT putting and additional bend in. Some people attempt to “mark” the former on top at the “point of bend” but you often have to change the position of the “stock” to get the measured conduit mark where you need it - as soon as you do this, the mark on the former will now be in the wrong place. Try not to over think it - bending conduit is more of a knack than an exact science. The ability to manipulate the bends neatly is the main skill. Practice makes perfect 👌🏻
@Ste2023
@Ste2023 Рік тому
This brings bk memories of browsing.
@VM-MV
@VM-MV Рік тому
thanks!! very useful video!
@headsup4sparkies
@headsup4sparkies Рік тому
Thank you …
@KeithWilliamMacHendry
@KeithWilliamMacHendry Рік тому
Excellent detail & instruction, thank you. 🙏🏻
@skabbymuff111
@skabbymuff111 Рік тому
Very informative, thank you. Subscribed.
@santhaariyarathna2262
@santhaariyarathna2262 Рік тому
Super
@CourtesyOfBR
@CourtesyOfBR Рік тому
Loved this vid, super simple and easy to understand compared to others, hope you release more content
@headsup4sparkies
@headsup4sparkies Рік тому
🙏
@gustavocervantes5435
@gustavocervantes5435 Рік тому
Great video
@headsup4sparkies
@headsup4sparkies Рік тому
Thank you 😀
@MultiOutdoorman
@MultiOutdoorman Рік тому
Fabulous presentation, excellent visuals too !.... If i might just contribute ? In my view, the purpose of the solar hot water system is to reduce the need for energy consumption ! The reason I mention this is because the solar needs to operate independently from the boiler . The D.H.W timer should be programmed to schedule a periodic " top up" of the storage tank to overcome any shortcomings of the solar performance during dull weather, and reduce legionella by bringing the water temperature up to a suitable level. My system for instance, runs twice daily to address water & / or heating, based on the Honeywell programmer settings. I also use an S-Plan too, using my combi boiler to provide heat, triggered by the room / cylinder stats leading eventually to the output of the microswitch in the zone valve(s). My kitchen hot tap still runs from the combi directly though ! It has worked a treat for about 6 years and i find the boiler hardly needs to run between May and end of September due output of the 8 square meters of thermal solar panels on our roof. The boiler is still timed to come on but the cylinder stat is usually open by that time so no heat is required. Winter time is another story ... but the boiler still only needs to heat lukewarm water already warmed in the bottom of the cylinder. I often wish i had a second tank in summertime as it often shuts the pump off and stagnates until somebody takes a midday shower. A "destrat" pump and a few controls help to maximise efficiency. Brill animation ... Thanks for sharing.
@headsup4sparkies
@headsup4sparkies Рік тому
Thank you very much for your contribution… this particular system is aimed at the AM2 requirements .. You are clearly experienced with these systems. From my own research, the only thing I can be sure of is that there is no such thing as a “typical” system.
@davidshanahan3693
@davidshanahan3693 Рік тому
Excellent tutorial.
@headsup4sparkies
@headsup4sparkies Рік тому
Thank you
@BlaqRaq
@BlaqRaq 2 роки тому
Very clear and easy to follow demonstration
@moali6196
@moali6196 2 роки тому
Great video well informed
@17italyman
@17italyman 2 роки тому
where you had the running coupler and lock ring can you not just measure say half of the coupler so that when you tighten up the running coupler with the end you wont have any tread showing ?
@headsup4sparkies
@headsup4sparkies 2 роки тому
I’m afraid not .. the running coupler needs to run from one piece onto the next piece. Therefore it will always leave some thread behind it. The way it’s shown leaves half the thread on the existing piece, and puts half the thread on the new piece. Therefore leaving half the thread exposed on the back of the existing piece, with both ends electrically (earthing) and mechanically secure.
@17italyman
@17italyman 2 роки тому
@@headsup4sparkies ah yeah makes sense now thank you
@17italyman
@17italyman 2 роки тому
@@headsup4sparkies also the nipple part you threaded into the box is this something for the am2 that they will provide ?
@frog.n.toast2938
@frog.n.toast2938 2 роки тому
great video. keep posting
@fraserreid719
@fraserreid719 2 роки тому
Wasting 4 inch of pipe I would get battered by my tradesman back in the day 😂
@headsup4sparkies
@headsup4sparkies 2 роки тому
😂🤣
@highgatehandyman6479
@highgatehandyman6479 2 роки тому
Good lesson
@2010Mrturk
@2010Mrturk 2 роки тому
I’ve hit subscribe but only 4 vids available. Can you do a vid on the DOL pls ?
@headsup4sparkies
@headsup4sparkies 2 роки тому
Actually working on Contactor and DOL video now .. once it is launched on the other platform it will be on here too
@TheGOLDRUSH817
@TheGOLDRUSH817 2 роки тому
Where can I find that bending station
@headsup4sparkies
@headsup4sparkies 2 роки тому
Pretty much any UK electrical wholesaler … here’s a link from a quick search www.toolstop.co.uk/irwin-hilmor-el32-conduit-bending-machine-with-vice-and-20-25-32mm-formers-t113100d-p80043/
@jeremykemp3782
@jeremykemp3782 2 роки тому
very good
@Tom-fu9cr
@Tom-fu9cr 2 роки тому
great video. really useful
@albertwesleyable
@albertwesleyable 2 роки тому
Came for the conduit, stayed for the music 🔥
@headsup4sparkies
@headsup4sparkies 2 роки тому
😂 … licence free rock n roll 😎
@xiakarimLive
@xiakarimLive 2 роки тому
What is the name of this bender? Where can I buy it from?
@headsup4sparkies
@headsup4sparkies 2 роки тому
There are different names, but I think the most common in the UK is made by Hilmor .. here’s is an example link from a UK wholesaler .. www.tlc-direct.co.uk/Main_Index/Conduit_Steel_Index/Conduit_Bender/index.html?ad_position=&source=adwords&ad_id=414374435730&placement=&kw=&network=g&matchtype=&ad_type=&product_id=&product_partition_id=&version=finalurl_v3&gclid=Cj0KCQiAwqCOBhCdARIsAEPyW9lmDNmlUux6qJls7H9S6mp5RPNTMG9YdOS4OYPuVNj5bmCCiSHvCiQaAn33EALw_wcB
@williamcerdasbonilla269
@williamcerdasbonilla269 2 роки тому
Exelente video amigo soy electrisista desde costa rica.... Yo para aser cambios de direccion o offset.. Tengo mi forma y se trata de tomar medida usar calculo con el teorema de pitagoras y centro marca dobladora y sale super biem amigo
@headsup4sparkies
@headsup4sparkies 2 роки тому
Gracias por tu bonito comentario. Me alegro de que te haya gustado mi vídeo. Diferentes naciones tienen diferentes formas de compensar. Creo que Estados Unidos también usa cálculos de Pitágoras. En Inglaterra, nuestras dobladoras no son muy precisas, por lo que las marcas fijas no funcionan tan bien para nosotros. Este método es más común en Inglaterra. Es fantástico para mí recibir mensajes tan lejos de mi casa. Muchas gracias.
@geoffplywood6112
@geoffplywood6112 2 роки тому
Very helpful demo, thanks
@sic2226
@sic2226 2 роки тому
Good demo.
@ef7480
@ef7480 2 роки тому
Like it. Just to point out, this is a '2plate' method or 'through the switch'. Ideal for downlights where only 2 conductors are prefered at the light fitting.
@headsup4sparkies
@headsup4sparkies 2 роки тому
Correct … combined with 2 way and Intermediate Switching. This is similar to the arrangement found in the AM2 😀
@georgeweston9024
@georgeweston9024 2 роки тому
I just recently passed my am2s assessment and want to say thanks. Your videos were very helpful in my preparation.
@headsup4sparkies
@headsup4sparkies 2 роки тому
Congratulations on your pass 👏🏻👏🏻.. glad to have helped
@danielcoyte8073
@danielcoyte8073 2 роки тому
How was it??? Mines been pushed forward to Monday
@connorrigg7878
@connorrigg7878 2 роки тому
Just a quick question if the depth was say higher or lower than 53mm would you shorten or add more on too the 100mm in between the sets ?
@headsup4sparkies
@headsup4sparkies 2 роки тому
You can increase the depth of the set by either making the 2 bends deeper, or by increasing the distance between the bends. In the AM2s there is a maximum length that the set can be, detailed in the spec. When setting out your bends you will need to decide what looks best and fits best in each circumstance. Hope this helps ..
@santoshkumargond6851
@santoshkumargond6851 2 роки тому
Great masterji tussi great ho
@identitywithheld1027
@identitywithheld1027 2 роки тому
The best demonstration on youtube.
@headsup4sparkies
@headsup4sparkies 2 роки тому
Thank you very much. I hope it was useful for you🙂
@identitywithheld1027
@identitywithheld1027 2 роки тому
Appreciate your generosity
@usmanrajput9005
@usmanrajput9005 2 роки тому
Great job
@headsup4sparkies
@headsup4sparkies 2 роки тому
🙏