10 Mistakes EVERYONE Makes When Doing DIY Electrics!💥

  Переглядів 124,951

Artisan Electrics

Artisan Electrics

День тому

DIY Electrics can be DEADLY - so in this video we reveal 10 things that lots of DIY'ers do with electrics that are SUPER DANGEROUS. If you're a DIYer and you're ever in doubt about how to do some electrical work in a safe way, just call a qualified electrician! What's the worst DIY mistake you've ever come across?
Tool of the day: Kewtech KT 1780 - amzn.to/43Gglzk
🚨Subscribe to our UKposts Channel for more great electrical content: ukposts.info...
➕Get more from Artisan Electrics here!👇
linktr.ee/artisanelectrics
Get a quote from us: app.openquote.net/company/art...
🔋Use my referral link to purchase a Tesla product and get free credits you can redeem for awards like Supercharging miles, merchandise and accessories.
ts.la/andrew24855
💬Artisan Electric Discord - Join our Electrical Community! 👇
/ discord
🔔 Become a Channel Member To Get Access To Exclusive Perks 👇
➤ / @artisanelectrics
Electricians Business Course
📩 Sign Up To The Electricians Business Course Here And Get The First 4 Lessons Free 👉 ➤ bit.ly/2Z582zI
🔔 Subscribe to TOOLS4SPARKS UKposts Channel 👇
We Also Have A Dedicated UKposts Channel About Tools:
➤ / tools4sparks
⏱️Timestamps
00:00 - Introduction
00:23 - DIY mistake 1 - A big NO
01:50 - DIY mistake 2 - Classic mistake
02:22 - DIY mistake 3 - This is a problem
04:17 - DIY mistake 4 - Be careful with this one
05:52 - DIY mistake 5 - Get the correct cable for the job
06:10 - DIY mistake 6 - Don’t make such a MESS!
06:40 - DIY mistake 7 - BIG risks
07:20 - DIY mistake 8 - Very common mistake
08:22 - DIY mistake 9 - Stripping back the wire way too far
09:37 - DIY mistake 10 - This could lead to a FIRE
PARTNERS/ARTISAN CODES
🔦Unilite Work Lights: Get 25% off all Unilite Products using our code "ARTISAN25"
UK Store - bit.ly/UNILITE
Europe Store - bit.ly/UNILITE-EU
USA Store - bit.ly/UNILITE-NA
Australia Store - bit.ly/UNILITE-AUS
💪🏼Powered by Hilti Nuron - hilti.to/nuron_range
💳American Express Business Gold Card
Sign up for an AE Business Gold Card using the following link to get a bulk of FREE membership rewards points - bit.ly/3JDmXVG
🥾 Big Boots - Save 10% on our amazing work boots when you use our discount code "ARTISAN10" at checkout here bit.ly/BIGBOOTS
📚 Get 10% off when you use our discount code "Artisan" at checkout Here - bit.ly/3uY94dW-StudyStickers
🔋 Save 5% on EcoFlow Products using code 'AE5' - dada.link/58lAne
🎵 Use music the Artisan Way - Sign up to Epicmedic Sound here 👇🏼
www.epidemicsound.com/referra...
TRADES INSURANCE DISCOUNT
🦏 Use Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
➤ www.rhinotradeinsurance.com/quote 📞 or call 01162437904.
ENERGY PROVIDER
🐙 Get £50 credit when you switch to Octopus Energy 👇
➤ share.octopus.energy/zappy-sh...
📈Make the most of your UKposts analytics with TubeBuddy - Sign up here👇
➤www.tubebuddy.com/ARTISAN
AMAZON LINKS
✅ Check Out All Our Favourite Tools Here 👇
➤ www.amazon.co.uk/shop/artisan...
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co.uk/tryAB?tag=ar...
📱 ARTISAN SOCIALS 📱
💬 Artisan Electrics Discord
➤ / discord
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
⏰ Artisan Electrics TikTok Account
➤ / artisanelectrics
💼 Artisan Electrics Linkedin
➤ / artisan-electrics
🎥 Get in touch with the Media Team
➤media@artisanelectrics.co.uk
This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own risk.
#sparkylife #electricianlife #artisanelectrics

КОМЕНТАРІ: 579
@artisanelectrics
@artisanelectrics 27 днів тому
If you want to make sure you are doing your job correctly, then you will need a proper test device for that. ⚡Kewtech KT 1780 - amzn.to/43Gglzk
@stuartandrews4344
@stuartandrews4344 20 днів тому
Should also include a link for a proving unit.
@VanyaYani
@VanyaYani 20 днів тому
It's rather KT63DL
@Techn4ne
@Techn4ne 17 днів тому
Laughing at soldering??? Are you honestly suggesting the way all electronics is made is wrong ?
@Cedar23
@Cedar23 12 днів тому
i was putting some lights up in friends bathroom and the replacement lights had multi stranded cables i put it into the connect and screwed it up pulled and it come out the connector so i though thats not safe, i had a crimping set i brought from lidle and i put like a small tube round the multiple strands crimped that onto there, did twisty 90* bendy thing it didnt come off so i put it into the connector block thingy and screwed it in made sure it didnt come out off that and then put the light to the ceiling, so i think i mad a fairly reasonable effort to make it safe. my general rule of thumb is pull on it and make it look pretty, if it dont brake with a pull and it looks need then its more than likely safe
@TestGearJunkie.
@TestGearJunkie. 6 днів тому
Prefer the Fluke 150 myself.
@petermorris3665
@petermorris3665 17 днів тому
Makes me want to do a video about the mistakes I've discovered done by qualified electricians on houses I have purchased over the years!
@waynethomas3638
@waynethomas3638 15 днів тому
what proof do you have(visual?)that they were done by qualified electrician?
@petermorris3665
@petermorris3665 15 днів тому
@@waynethomas3638 e.g. New build house with contract for whole estate done by very large contractor. Etc.
@feanor5037
@feanor5037 15 днів тому
Over-tightening terminals on copper wire is a favourite. Fine for a few years but the excessively squashed conductors can fail and create points of high resistance EDIT: lol just got to the bit where this was mentioned as a DIY mistake but the pros do it all the time 😅
@Pes60
@Pes60 14 днів тому
As with any profession there are good ones and bad ones.
@bendingspring
@bendingspring 14 днів тому
Please share what you have come across, it may save someone’s life.
@robhills9769
@robhills9769 17 днів тому
The heat produced in a wound up extension lead is NOT caused by induction. It is caused by conductor resistance and lack of cooling.
@AzrethK9
@AzrethK9 15 днів тому
Exactly! Bifilar coils like this cancel out the magnetic field nearly completely. Not knowing about reduction Factor on stacked cables and it's danger is a typical DIY mistake.
@PietroPasquero
@PietroPasquero 15 днів тому
Sometimes making fun of others can backfire.
@MatthewWellings
@MatthewWellings 14 днів тому
To expand on these accurate comments by op & @AzrethK9. Yes the coil is definitely Bifilar and therefore a non-inductive coil for this purpose (basically the magnetic field of the neutral cancels out the live, why you can't use clamp meters on power cords). Additionally self-induction is not a method of energy dissipation, it is a form of energy storage. If the coil was inductive the energy world be stored in the magnetic field and released later in the AC cycle. This why PFC devices are called for on inductive loads, they don't affect your real power consumption, just the power factor. What this is, is an example of a hazard caused by bundling many (slightly resistive) conductors together and there being nowhere for the heat to go. Think of it like wrapping the inner wire in a blanket, and an electric blanket at that. This same hazard would occur if there were many separate cables all carrying this current, this is a hazard electricians should understand. I think this myth may come from two places, people knowing a coil can be inductive, assuming it is because they don't know what an inductor is; and then assuming that one thing they now see is the cause, ignoring the obvious real cause they should already know about. The other possibility is people are thinking about induction hobs, which is a whole different situation, firstly they use an inductive coil and secondary (pun intended) there is a pan to act as the other, shorted, winding.
@malectric
@malectric 6 днів тому
One cat we had used this to good effect - it would curl itself up and go to sleep on a coiled extension lead feeding a heater.
@reinhard8053
@reinhard8053 5 днів тому
Exactly. Even if it wouldn't be bifilar, the number of winds and the low frequency would lead to no real inductive effect.
@Speeder84XL
@Speeder84XL 20 днів тому
Fun stuff and so typical mistakes for many DIYers. But the wound up extention cord running hot, has nothing to do with inductance. It simply the resistance of the cable that cause it to heat up - but being rolled up like a coil, the heat can not escape from the cable very easy (compared to if the cable is rolled out), so the temperature rise quite a lot As the resistance of copper also goes up by the temperature, this causes it heat up even more in a sort of thermal runaway. This can cause the coil of cable to get toasty, very quickly.
@Firebird1005
@Firebird1005 20 днів тому
Could not give you two thumbs up.
@aardwolf21
@aardwolf21 20 днів тому
three thumbs up, the out and return are parallel, so loop area is negligible in this instance , so inductance is negligible, surprised at Jordan for getting that wrong.
@massimomacucci7461
@massimomacucci7461 20 днів тому
Right, and I would like to add that, even if there were a significant inductance (which is not there because the magnetic fields due to the two opposite currents cancel almost perfectly) it would not lead to any power dissipation, only to a lossless voltage drop. It is only the resistive part of the impedance that leads to power dissipation and Joule heating. I do not know why this incorrect belief about the hypothetical inductance and even more hypothetical associated power dissipation of coiled cables consisting of two conductors with opposite currents is so common: I heard it for the first time in high school when I was working part time for a local tv station: a technician from.a local tv production company told me that power cords for halogen lights should not be wound in operation motivating the recommendation with the incorrect inductance argument.
@444mikeee
@444mikeee 20 днів тому
waiting for his reply on this.. haha. ironic how the video is specifically about making mistakes.. lol
@artisanelectrics
@artisanelectrics 20 днів тому
Thanks for the clarification! That does make sense 👍
@grahamelvis6473
@grahamelvis6473 17 днів тому
Extension leads - Inductance is not the problem, it's the resistance that creates heat. Cable is rated for a situation where air can circulate around it. Winding it onto a reel adds insultation so the copper temperature rises.
@andreasbentz6106
@andreasbentz6106 20 днів тому
Another vital step for #7: Check your circuit testing device for proper operation before you rely on it....
@nickryan3417
@nickryan3417 17 днів тому
Yep, it doesn't really have to be a very expensive device either, but testing that it shows a circuit before turning off the power at the distribution board and the looking for the difference is really important. Even when having done this I do have the slightly (bad) habit of intentionally bridging live and neutral because if there's a pop and a circuit breaker kicks in, I'd rather that it do this when I expect it!
@tridentmusic5570
@tridentmusic5570 12 днів тому
Strickly, you should also check your tester immediately AFTER checking the circuit - to ensure that the tester didn't fail JUST BEFORE,or during) your test ! Pro's will have some independant voltage souce -or use knowingly energised circuit.
@andreasbentz6106
@andreasbentz6106 12 днів тому
@@tridentmusic5570 You are right, but I haven't seen anybody doing that, except the guys who work in secondary substations. In household installations it is more common to create an intentional shortcut after testing just to be on the safe side. At least that's the case for Germany. Cheers Andreas
@tridentmusic5570
@tridentmusic5570 12 днів тому
@@andreasbentz6106 Agreed.
@33andy33gmail
@33andy33gmail 20 днів тому
Seen a few qualified electricians just lash cables all over the loft joists unsecured. Done with the right mindset a DIY job can be done with more patience and care than your average electrician!
@artisanelectrics
@artisanelectrics 20 днів тому
Very true!
@martinw245
@martinw245 20 днів тому
Yep, my brand new house was a bit like that in the 90's. Some cables were clipped but many just strewn on top of the insulation.
@nickryan3417
@nickryan3417 17 днів тому
Exactly the case here. Loose cables just flung over the top of the joists, not run properly in any way. Add in the person who put loft boards in the loft not knowing to screw the damn things instead of nail them and to interleave the boards and I had a flooring mess. What made it worse was because of the half-arsed wiring job done gaps had to be left in these already flimsy loft boards and the "fix" was to just leave a gap and dump another board over the top and nail that in place too. I'll be redoing all that wiring at some point, running it properly through the joists but it's a tedious task - it's a flat and it's both sockets, lights and storage heaters that have been wired like this. For extra fun I found that one of the storage heaters had been wired into the lighting circuit in the distribution box. Genius.
@p_mouse8676
@p_mouse8676 6 днів тому
In some countries this seems the norm. It brings shivers down my spine. Why not just spend a couple of minutes just to make it tidy?
@martinw245
@martinw245 6 днів тому
"Done with the right mindset a DIY job can be done with more patience and care than your average electrician!" Yes, that's very true. Anything I've done has been permitted, and with extreme care and attention, precisely to the regs. A better job than a pro electrician that does the minimum. What pro's don't notice, is the excellent DIY, because its indistinguishable from a professional job.
@cjs95
@cjs95 18 днів тому
One other thing not mentioned, but something I've not seen done in a fair number of outdoor DIY cabling setups are Drip Loops. Instead you tend to see cables running straight down a wall, right into a junction box with nowhere for the water to go!
@AintBigAintClever
@AintBigAintClever 16 днів тому
I've seen the same done by professional CCTV installers recently. Cameras had gone out. I checked the weatherproof enclosure, unscrewed the cover and about a litre of water poured out. All cables were top-entry, no drain hole, system had worked until water got up to the level of the power supply for the network switch. Also not-so-professional cable contractors (I won't name names but let's just call them the S*** Wiring Guys) running Ethernet feeds into the tops of Wiska 308s or through drilled-out holes in the rear. As they fail the cables just get jelly-crimped now as if the jack is replaced it just rots again.
@DIEMLtdTV
@DIEMLtdTV 20 днів тому
As the legendary oil rig fire fighter Red Adair said “If you think that hiring professionals is expensive, try hiring amateurs.”
@jonathanblankley3546
@jonathanblankley3546 20 днів тому
Very, very true - in many industries.
@viewfinder914
@viewfinder914 19 днів тому
Love it. I am going to use that more with my Senior Managers in Health Care...
@Hertog_von_Berkshire
@Hertog_von_Berkshire 17 днів тому
Red Adair in a rare moment off from dancing with Ginger Rogers.
@grahamheath3799
@grahamheath3799 16 днів тому
Err how can you hire an amateur; only means somebody isn't be paid!!!!
@saw6386
@saw6386 16 днів тому
​@grahamheath3799 there's always one.
@paulgrep3193
@paulgrep3193 20 днів тому
Electricians trade is like no other for slagging off everybody else's work except their own.....
@chuckmaddison2924
@chuckmaddison2924 20 днів тому
This happens in all blue-collar jobs. Doesn't happen in professional services, eg medical or legal. Probably indicative of education.
@jamiekent1970
@jamiekent1970 20 днів тому
Jordan loves to slag off the customers (DIYers)😂
@AndrewStrydomBRP
@AndrewStrydomBRP 20 днів тому
There is some reason for it I'd argue, especially when electrics are one of the most dangerous things one can play with in a house, alongside gas. It has to be done right, there's no room for corner cutting or mistakes.
@Scimu
@Scimu 20 днів тому
@@chuckmaddison2924absolutely does happen in medicine and legal. Humans are humans.
@seantaylor9758
@seantaylor9758 20 днів тому
I've employed several 'qualified' electrical contractors and had some really shoddy work completed. Be carefull not to employ an electrician that doesn't know what he or she is doing.
@sebastien79a
@sebastien79a 20 днів тому
Some of those DIY fails like clipping I've also seen from "professionals" trying to rush a job :)
@artisanelectrics
@artisanelectrics 20 днів тому
Very true!
@Aspie_Geek_UK
@Aspie_Geek_UK 19 днів тому
I'm in my 50's and did a 5 year apprenticeship as an Electronics Technician when I left school. I then became good friends with an Electrician who over the years taught me a lot about household electrical wiring etc. As a result I feel that I'm relatively competent as a DIYer and myself have seem some hacks that were so dangerous I physically shuddered at them. Every bit of work I've ever done on my house electrics, I have an electrician come out and check it. When I built my workshop in the garden 20' x 10', I fitted a 20 socket ring main and 12 light ring. I ran the Armour cable to the CU and had an electrician come check it and connect it up. He said he had no qualms with connecting it and certifying it as the job was good. My point isn't to "big up" my skills and knowledge, but to point out that not all DIYers are terrible, some of us actually go out of our way to make sure we do a good job because we realise that our lives and the lives of our families are very much on the line.
@John_L
@John_L 17 днів тому
Indeed so. I'm also an electronics engineer and would never make any of the DIY mistakes mentioned here. I also know that it is not inductance that causes a rolled up extension lead to get hot! Unfortunately Part P has turned us DIYers into criminals and, by making the relevant standards inaccessible to non qualified persons made it far more difficult for those of us trying to do a decent job to do so.
@deang5622
@deang5622 17 днів тому
The issue for you, that today, some of the work you did is considered _notifiable_ and by law, the Building Control department of the local council has to be notified. Even if you are competent as a DIYer, you still have to notify the Building Control and they will tell you what certification requirements are needed. And as you don't hold any formal qualifications, and no membership of NICEIC or NAPIT, then they will require that a qualified electrician inspect and sign it off as being compliant to the wiring regs. So I think it is important to not send out a message that anyone can just go along and do their own electrical DIY and get an electrician to sign it off. There is more to it than that.
@deang5622
@deang5622 17 днів тому
​@@John_LNo, it is not true that Part P has turned people into criminals. I have repeatedly seen statements made by even electricians that say people can't do their own electrics. That is not what Part P of the building regs says. Part P says that the work has to be done to compliance of the wiring regs, and be certified by somebody competent and it talks about notification to the building control department.
@John_L
@John_L 17 днів тому
@@deang5622 This is true but by making the said wiring regs only available to certified personnel the effect is to make it nearly impossible for the conscientious DIYer to do a compliant job. And the DIYer is criminalised unless his work is inspected, even if it is not notifiable work. The practical effect is indeed that the DIYer cannot do his own electrics, no matter how competent he is.
@Aspie_Geek_UK
@Aspie_Geek_UK 17 днів тому
@deang5622 yes but you obviously missed the part where I said it was inspected and checked/tested by a qualified person who then issued the appropriate paperwork. the work I did on my workshop was done back in 2011and as I said, I had an electrician come out to connect it to the CU, I left all the socket fronts off and the lighting covers on the flourescents off so he could see the job I had done and also marked out my cable runs that are behind the OSB that lines the inside, I also have a couple of covers that give easy access to some of the areas where the cable runs incase I need to do any work on it. He was happy enough to sign off on it and to connect it to the house CU. I ran the Armour Cable and routed it to the CU in the garage and again after testing it he was happy to sign off and complimented me on a good job. The result is, I have an ele tri ally safe workshop that has been in use now for 13 years with zero issues (except a small leak in the roof I just had to fix🙄). I have also had another electrical inspection about 2 years ago and they checked the workshop because its connected to the household CU so included it as partnof the house and again had a clean bill of health. Based on all this, why am I breaking the law? Yes I did the work, but didn't make the final connection and it was all tested by a qualified person 🤷
@okaro6595
@okaro6595 20 днів тому
The cord is not about induction but simply resistance. When it is wound up it cannot dissipate heat and cool. Once it heats up the resistance increases and it heats even more. All those thermal protections, as well as fuses and circuit breakers are in case an overload happens. They are not some permission to load as much you can and rely on them to cut.
@stpeter7432
@stpeter7432 20 днів тому
Absolutely correct! At any point in time the current in the L and N conductors will be flowing in opposite directions and are physically very close together so the magnetic fields cancel.
@callumcurtis15
@callumcurtis15 20 днів тому
I was very suprised he made that mistake .
@jounisaari9471
@jounisaari9471 20 днів тому
The resistive heating is an issue also, if wire is heat insulated. Adding heat insulation to a wall or ceiling without remaking electric installation may be fire hazard. Even more important in boat or camper. Low voltage cabling uses high current, and hiding a 1,5 mm2 wire inside good foam insulation and using it just with 120W may be enough to cause a fire. With battery a shorcut ends up to red hot wires very quickly, and insulation can melt and cause short circuit.
@stpeter7432
@stpeter7432 20 днів тому
@@callumcurtis15 Yes! Especially when he's criticising DIY installations from an expert position - Physician, heal thyself!
@bikerfirefarter7280
@bikerfirefarter7280 18 днів тому
​@@stpeter7432kind of true, but only at low frequencies. I know I'm nit picking.
@andyb410
@andyb410 19 днів тому
Another common mistake is pushing the wire too far into the terminal so that the screw is tightened onto the outer insulation of the wire rather than the copper, thus no connection. Particularly bad if done to the earth.
@Graham_Langley
@Graham_Langley 19 днів тому
I get cable pulled from domestic kitchens being refitted and this is probably the most common issue after terminal blocks wrapped in insulation tape.
@BenHorton1066
@BenHorton1066 17 днів тому
Wow so that was wrong squared. The induction was not the problem on the extension cord It was simply the thermal resistance of the cable to air.
@Ian-xq4rt
@Ian-xq4rt 20 днів тому
As a DIYer, after seeing this, I feel very competent in my work. I use a very old and reliable Fluke multimeter for various tests, would never dream of all the things you've covered here so I must be in the 'safe' zone (although I have electrocuted myself twice but isn't that to be expected, the first time was as a young child with poking wire in a socket🤣). After visiting my loft, I can say that it's a mess, clearly the electrician wasn't to our standards. I have a 10 meter EV charger cable which I always unwind regardless how close the car is, just to me, common sense.
@SteveGroom
@SteveGroom 20 днів тому
Using snips to remove the outer sheath and cutting into the inner insulators and partly exposing the copper. Not always visible but a real danger for getting a shock.
@artisanelectrics
@artisanelectrics 20 днів тому
That’s a good one too!
@nickryan3417
@nickryan3417 17 днів тому
Yep, it's a very easy thing to do too. I love my proper wire cutters but even these don't work on all cables as well as I'd like.
@foogod4237
@foogod4237 20 днів тому
Good call out with the coiled-up extension lead. That is something I don't see enough people talk about, to be honest. (As others have pointed out, it's not actually about induction, it's actually just about not having enough airflow to properly cool the wire, but the main point is still a good one.) And yeah, you had a pretty nice one there with a thermal cutout and everything, but a lot of them don't have that. It doesn't even have to be one of the really long ones with their own carrying spool like that one was, just a plain extension wire that somebody has left coiled up in a loop sitting on the ground can get a lot hotter than it's supposed to if a decent amount of power is pulled through it. And the reason you don't want extra exposed conductors even inside a box is because sure, it works _now_ but then later somebody comes on and moves something around and something falls on one of them or one of them gets pushed into something else and all of a sudden you've got a dangerous short. It's not just about getting things to work right at that moment, it's also about making sure they won't go horribly wrong somewhere down the line, too. Oh, and with the screw terminals, one other important point, IMHO: *Always tighten them twice.* Screw them down initially, then move the rest of your wires around, get everything properly in place, and get ready to button the whole thing back up, and then go around and _make sure all the screw terminals are still tight._ It's amazing how often they can become loose just from moving stuff around after you've initially tightened them (part of the reason I much prefer other types of connectors like the WAGOs when they're an option).
@coniow
@coniow 18 днів тому
I well remember a case when I was on a Tech Theatre Course back in the Eighties. The theatre was adjoining the old Victorian house, and while the LX had it's own supply, other equipment tended to be run from the house's supply. On this show the whole stage had been painted with size paint and then sealed with Emulsion Glaze (PVA). During the night there had been a leak and the stage was soaked, walking on it would rip up the paint, and that was a key part of the show. So. Every heater we could find was put on stage to try to dry it before the afternoon Matinee. Couldn't even mop it, it was so soft! So the extension cable (at full length), got hotter and hotter, then blew the fuse. The Chief LX on the show went to the fuse box and pulled this huge, palm sized ceramic MK fuse out without thinking, and got MK branded into his palm. Nasty!
@1990Judson
@1990Judson День тому
At least he was able to pull it out. I have seen this things get welded in place
@AlanTheBeast100
@AlanTheBeast100 15 днів тому
Coiled extension has current running in opposite directions (hot ("live") out, neutral back) so induction is cancelled out. It's simply that with enough current the cable heats and because it's coiled the heat isn't dissipated as it would be on an uncoiled line.
@johnchristmas7522
@johnchristmas7522 20 днів тому
I remember, many moons ago, when we had a call out to house where the little girl had got a shock. To our utter disbelief, the DIY clown had wired the lighting circuit, on the surface, with the very old purple fabric twin flex cable with uninsulated staples to the wall and ceiling, even the excess cable too!! The little girl got the shock from a live staple near the switch!! I've also come across a whole house wired in bell wire! Had another occasion where I went to help another spark in the middle of trying to rewire a house. I couldn't believe the state of the place, the other spark John was trying to get under the floor in the lounge. RUG nailed to floor, then Lino, then 8x4 board nailed and then tongue and grooved floor boards-different from the norm, in that the boards were grooved female both edges and the tongue was a METAL strip between them!! Sorry to say I left when the woman complained about the mess!! Gave up on house bashing years ago. Good luck you lot!
@BerkeleyTowers
@BerkeleyTowers 20 днів тому
Back to school for Jordan with the "induction" heating... If it was wound around a metal core with a load more current at a frequency in the kHz, then maybe...... Boring old resistance heating I'm afraid. Do your media team not fact check?
@foogod4237
@foogod4237 20 днів тому
Well, the explanation was not quite right, but the actual issue and main point is still entirely valid, so I'm still glad he mentioned it, at least. Coiled up extension leads can get a lot hotter than they're supposed to (really just because of lack of airflow for cooling), and that can actually be a real problem in some cases, so you definitely should always uncoil them and separate them if you're pulling any kind of significant power through them...
@BerkeleyTowers
@BerkeleyTowers 20 днів тому
@@foogod4237 when you say “not quite right”, you mean not even close…… the same outcome does not not justify an incorrect explanation. Especially so when the whole video is berating “DIY” practises in the first place. And even more so when these supposed DIY practices have plenty of precedent of being done by so called “professionals “ in the first place.
@deang5622
@deang5622 16 днів тому
There are two different things in this which the video presenter has confused. 1. Induction coil 2. Solenoid We don't have 1 here, we have 2. And in the case of 2, we actually have two solenoids interwoven, comprising one turn of line one turn of neutral and this then repeats for the full length of the solenoid. Both line and neutral coils are wound in the same direction, so both coils will produce a magnetic field each in the same direction if the direction of the current in both coils is in the same direction. However, as we know, the line and neutral currents are in opposite directions which means the magnetic fields are in opposite directions. Assuming no earth leakage, then the line and the neutral currents and the same magnitude. The net effect is the two magnetic fields are equal and opposite and cancel each other out. So no magnetic field. It is very common for electricians not to understand much about solenoids other than they create a magnetic field. I have seen had an argument with a sparky on this channel that tried to argue the inductance was zero and quite firmly stated that the inductance is not related to the physical properties of the coil. Something seriously going wrong with their education in inductance and solenoids. But I guess, an electrician trains electricians. So the myths perpetuate.
@josephchamness9915
@josephchamness9915 14 днів тому
@@deang5622 Can an inductive or capacitive load shift the current on the return line?
@HA05GER
@HA05GER 20 днів тому
The whole plugging extension inti extension doesnt really apply here thats why the fuse exists. its actually quite hard to overload ive tried just out of interest. Now all these are common sense i genuinely dont get how people think any of this is ok. Ive seen people do it and my mind just cant comprehend how they think its safe.
@bikerfirefarter7280
@bikerfirefarter7280 18 днів тому
You are missing the fact that 'common sense' is actually rare and becoming rarer, often pushed out of the situation by dumbass ego.
@bikerfirefarter7280
@bikerfirefarter7280 18 днів тому
Also 'idiots' are quite willing to bypass fuses because to their mind a blown fuse is because the fuse is faulty, like a blown light etc, therefore they jury-rig a fix because of that perception of 'what do these so-called 'experts' know? It doesn't blow when I fix it . Therefore I know better than them. It's false logic, but ignorance and ego drives them onwards. QED.
@adrianmawby9009
@adrianmawby9009 18 днів тому
Plenty of solar panel fires where the installation was carried out by professional electricians. Plenty of factory fires put down to electrical faults , that's not an installation done by DIY. As an electronic engineer , I have seen many machine tools damaged by electricians who think they are qualified to work on anything from a torch to a nuclear power station.
@rodbicke
@rodbicke 17 днів тому
As a professional, I have stuffed up. No one is perfect. The professional makes far fewer mistakes, because of the long training and continuous learning of the day work. Unfortunately there are some who know better, but take short cuts at every turn, not good for the trade.
@deang5622
@deang5622 16 днів тому
​​​@@rodbickeNo. He is criticising electricians, not professionals. Specifically electricians. Electricians that think they are experts Electricians should not be making safety critical mistakes. It is not acceptable to make safety critical mistakes and say "Oh it happens". That is not good enough.
@wisteela
@wisteela 15 днів тому
Great stuff. I've got a Jo Jo extension reel from the late 80s with thermal cut out. Yes, still working fine.
@BarneySaysHi
@BarneySaysHi 19 днів тому
What I'm missing with the screw on plug is a longer earth wire. I've been taught in school that the earth wire should be a bit longer than the live and neutral. That way, in case the live or neutral pop out, the device is at least still grounded.
@ge2719
@ge2719 17 днів тому
thats why the earth pin is at the top and theres a space by the earth pin terminal for the earth wire to coil around a bit, so it can be a bit longer and the extra length fits in that space.
@cdl13
@cdl13 11 днів тому
The wound up extention could also apply when people are using their vacuum cleaner with the cable wound up inside, not fully pulled out(like a Henry type vacuum). I used to service vacuum cleaners for a cleaning company as an apprentice and we regularly replaced the flex cable inside the vacuum cleaners. The cable had melted together the outer layer inside the coil causing the cable to not be fully deployed. This of course caused a further issue with further melting. Fortunately we never had any fires, but cleaners would complain the cable could not be pulled out properly. We would try to educate the cleaners to "fully pull out the cord" when using the vacuum.
@johnny71c
@johnny71c 20 днів тому
Well done on making this video Jordan. You are educating the masses to their mistakes and making people more aware of how dangerous their action can be. I was an electricians mate and have seen some of the bell wire to lights in attics and sheds or even two core and cpc outside and a family memeber even had two core and cpc on a catenary wire from house to shed lol. I soon isolated the circuit and swapped it out with some Hi-Tuff along with fitting a metal clad socket in the shed. I would always crimp my flex cable before terminating with a scew.
@johnh9449
@johnh9449 19 днів тому
It's not inductance that overheats the extension lead as the fields will cancel from live and neutral carrying currents in opposite directions - it's a lack of thermal conduction to circulating air of which three is none when it's tightly wound.
@chrishard7616
@chrishard7616 7 днів тому
That implies the cross sectional area of the wire is really under sized then.
@johnh9449
@johnh9449 7 днів тому
​@@chrishard7616 It's the right cross section when unwound and in free circulating air. When tightly spooled the I²R loss is too high when concentrated in the small space. You could have a thicker wire to reduce the i²R loss so it doesn't overheat when tightly spoiled but of course a thicker wire wouldn't fit on the same size spool and you'd end up with a much bigger, heavier and more expensive extension reel. These things are always compromises. It will work at 13A when unspooled and perhaps only 4A when spooled (continuously) or short periods at 13A to limit temperature rise, perhaps relying on a thermal cut out switch.
@kcj1993
@kcj1993 16 днів тому
It's not induction, just resistive heating
@davejblair
@davejblair 15 днів тому
Great video Jordan. As a DIYer I think the advice you're giving is spot on. Discovered the coiled extension risk the hard way as a kid in the 80s (those were the days!). I think most competent DIYers, and professionals are already aware of these points but make mistakes out of haste, lack of the right tools to hand, or a an optimistic approach to risk rather than ignorance.
@IAAITKEN
@IAAITKEN 10 днів тому
Another good and informative video. Thankfully know them all and always over cautious. Often shocked doing PAT at work. Amount of new extension cables where we fail the plugs out the factory and refit or reterminate wires.
@evicol2117
@evicol2117 20 днів тому
7:45, use ferrule crimp ends (shoelace crimp). Not only do you crimp once with your tool, the screw itself will compress the wires against the ferrule and they won't separate or spread out, ensuring a solid connection. I don't know why people don't use them on stranded wire outside the EU. Every time i see one without a crimp, I cringe.
@apk55
@apk55 20 днів тому
Must admit I like using ferrules - got some a few years ago (with crimp). While not an electrician as a retired electronic engineer I know more than most.
@Graham_Langley
@Graham_Langley 19 днів тому
@@apk55 Discovered simple ferrules for flex termination years back.
@imaginitivity7853
@imaginitivity7853 18 днів тому
I need two on the second meter tails i just upgraded (from the insufficiently sized cable the previous diyer did). But I'm not going to buy a tool just to crimp two ferrules!
@imaginitivity7853
@imaginitivity7853 18 днів тому
Professionals work on live boxes. You just have to be mindful. Otherwise you're working in the dark!
@evicol2117
@evicol2117 17 днів тому
@@imaginitivity7853 I crimp hundreds of wires every day since I'm building automation cabinets with PLCs and drives and other stuff, so I really need it, but on installations with solid core, I guess you don't really need it. But my point stands. Multi core wire should be always crimped unless connected to a spring terminal. Push terminals and Screw terminals need the crimp.
@ZROZimm
@ZROZimm 17 днів тому
In our first house I was swapping out some ceiling light fixings. So, I turned off both "Lighting" Fuses at the box. But, in a bungalow, with full access to the cables in the loft space, I quickly found that the bathroom lighting was hooked into the socket ring. Quickly and sharply. Learnt an important lesson about other people's work and the value of test equipment that day.
@ge2719
@ge2719 17 днів тому
similar situation where i found out the garage lights were running off the kitchen sockets ring.
@MartinE63
@MartinE63 20 днів тому
10 mistakes EVERYONE makes when doing DIY electrics? Not this one. I’m fed up of fixing bodged and lethal installations by so called ‘pros’ My next job is trying to work out how a ring main (in PVC) that happily existed for over 60 years totally lost one leg, as in the entire cable is missing at the consumer unit when a so called pro did the wiring for a gas boiler by bodging in a spur at an unknown location and by unknown methods. All the existing cables appear to be buried in the original plaster. I’ve temporarily changed the MCB for a 16A as a precaution. 🤬🤬🤬🤬🤬
@tlangdon12
@tlangdon12 16 днів тому
The point that the title of the video is insulting to those DIYers who have enough knowledge, experience and tools to do simple jobs relatively safely is well made.
@deang5622
@deang5622 16 днів тому
I suspect many DIYers are more intelligent and more capable than many electricians. The issue will be around the DIY'ers level of knowledge of BS7671 and the requirement under Part P of the building regulations. A copy of the On-Site guide will help DIYers do work to the required BS7671. And then get the work certified by an electrician. Read Part P to understand the principle of notifiable work, what constitutes notifiable work and what to do.
@shaun30-3-mg9zs
@shaun30-3-mg9zs 20 днів тому
Hi Jordan, I enjoy your video's but I am not an electrician I only do the basics, one of my biggest electrical pet hates is wrong size fuses in plugs about a month ago we bought an electric hand held food blender only 175 watts but fitted with a 13 amp fuse that to me is a safety issue by the manufacture and against the warranty I swapped the 13 amp fuse for a 3 amp it works fine its just down to basics. I can understand with power tools a 400 watt drill will be fitted with a 5 amp and not a 3 amp because of the start up of a motor. Great video thanks for showing Take care
@davideyres955
@davideyres955 20 днів тому
The fuse protects the wire not the power draw of the device. Although you may have a low wattage it may well have a higher inrush current and that could blow the fuse. Unlikely with the figures you have given and fuses have a degree of inrush allowance.
@shaun30-3-mg9zs
@shaun30-3-mg9zs 20 днів тому
@@davideyres955 Hi David, thank for your reply, but would a 13 amp fuse blow on some thing with very little power if there is a fault on the appliance the cable is only 0.5mm twin flat flex, I am not electrician but I was told to use the correct fuse for the wattage of the appliance, once again thanks for your info
@foogod4237
@foogod4237 20 днів тому
@@shaun30-3-mg9zs The fuse should be sized to a maximum of what the power cable of the device can handle, or 13A, whichever is smaller. Most appliances have cords which can handle 13A, even if the device itself is never intended to draw that much, so a 13A fuse in the plug is fine (it will still trip before anything gets hot enough to cause damage/fire). However, if your device has a cord with 0.5mm^2 conductors, then that probably shouldn't go over 5A or so, so yeah, a 13A fuse is arguably wrong in that case.
@shaun30-3-mg9zs
@shaun30-3-mg9zs 20 днів тому
@@foogod4237 Thank you very much for your reply. just concerned
@riptiz
@riptiz 20 днів тому
I wanted some two fluorescent lights fitting in my shed years ago and didn’t know how to wire them. My dad suggested going to one of his neighbours who was a sparkys mate. He asked what type of fuse box it had and I told him the wired fuse types. He took me in his shed and wound loads of fuse wire around a dolly peg. As he handed it over he said ‘ I don’t know how to wire it but by the time you have used all this, you will have figured it out’. I was absolutely speechless!
@asdreww
@asdreww 11 днів тому
Not to talk down what electricians do, but a DIY'er is easily capable of doing the basics in a typical house - wiring radials or ring circuits for sockets, lights, downlighters etc, to the exact same or likely better (because you always take greater care over your own stuff!) standards of an electrician.
@BedsitBob
@BedsitBob 18 днів тому
The ceiling rose is the thing that confuses more DIYers, than probably anything else. I've been called by a few panicked DIYers, where they've charged in and disconnected, only to find more wires than they expected.
@Graham_Langley
@Graham_Langley 18 днів тому
Had to sort that one out for a neighbour recently. Seemed puzzled that I could sort it while chatting about something completely different.
@BedsitBob
@BedsitBob 17 днів тому
@@Graham_Langley It's easy enough to sort out, if you understand how the circuit works.
@gordonm2821
@gordonm2821 17 днів тому
That is the trouble they buy a new light fitting from DIY store and it wants L, N, E and you pop open ceiling rose and there are loads of wires!
@tomwimmenhove4652
@tomwimmenhove4652 20 днів тому
The reason that a wound up coil of wire is not because it creates an inductor. I've heard this myth many times before. The actual reason is pretty simple: an unwound coil simply has a lot more surface area to dissipate away the heat. When it's coiled up, it traps all the heat generated inside of the coil and has nowhere to go except for the minimal surface area that's exposed to the air. This increases the temperate of the conductors inside the coil, since they're effectively insulated, while, at the same time, being heated by their surroundings. There are simply fewer routes for the heat to escape.
@artisanelectrics
@artisanelectrics 20 днів тому
Thanks 👍
@DickFrancis-dt3tl
@DickFrancis-dt3tl 20 днів тому
You beat me to it! Yes I've also seen that myth about induction before, apart from anything else as the current flows through both live conductors but in opposite directions the magnetic fields cancel.
@BlueJDev
@BlueJDev 12 днів тому
Nice to know as a diyer I've not made any of these mistakes. I even have my own live tester beeper. A note on the last one, some extension reels only use the trip/reset on 2 of the four plugs, well mine does anyways(could just be broken), my kid used a 2kw heater on the wrong socket. It didn't trip, nearly caught fire and also melted the wall socket the reel was plugged into! In the other 2 it trips very easily with the heater unless fully unwound.
@lonewolfgeoff
@lonewolfgeoff 20 днів тому
i saw the pic for the vid and thought... "jordan is lethal?!" 😱😳😂😂😂 good vid! bit of an eye opener!
@artisanelectrics
@artisanelectrics 20 днів тому
😂😂😂
@waynethomas3638
@waynethomas3638 17 днів тому
As an electrician of over 50 years experience I was taught as an apprentice to twist wires together before screwing into terminals!
@retrozmachine1189
@retrozmachine1189 15 днів тому
Still the procedure in Australia.
@jocramkrispy305
@jocramkrispy305 14 днів тому
pretty sure efixx still show it.
@drpainnuk3d
@drpainnuk3d 20 днів тому
Thanks! This was great to watch and know
@halesworth01
@halesworth01 20 днів тому
GOD your first one 'The Twist' I'm a DIYer and would NEVER do that, I would prefer to wait for a day and buy some Wago's off Amazon, and anything out of my league get a sparky in!
@DavidAlanStanley
@DavidAlanStanley 18 днів тому
Thanks for some great tips. Thankfully, I was already aware of them although the coiled cable was a quite scary. When removing ceilings on my old house I found "rewired" lighting meant, in some places, a few twisted wires with a bit of insulating tape wrapped round them... 😲
@steveb1856
@steveb1856 20 днів тому
Speak for yourself, don’t keep denigrating DIYers who know what they are doing and do better than some of the cowboy electricians that are out there. As a DIY er I’ve improved the appalling wiring (probably done by the builder who built his own house) in our 1970s house. Single ring for an entire 3bed detached house including immersion as a spur off the ring. It had lots of wire nuts and twisted connections! Borrowed neutrals. I’d just go read BS7671 and the on site guide and do it properly. Added separate radial for the immersion, which is no longer used but it supplies power to the loft for the digital shower and axial fan, I split the single ring into two rings (proper and continuous), re wired the kitchen, garage and boiler house. They used to stock the IEE wiring regs in WH Smith’s in town, I used to go read and memorise before doing work. Only thing I’ve lacked over the years is a MFT. But subsequent PIRs (EICR for the youngsters) have shown the installation to be sound including the fixed borrowed neutrals. Did have reputable a local spark in to change the CU to full RCBO board 14 years ago and recently had spark in to replace the RCBOs and main switch but kept the enclosure. Not paying Artisan prices to do something I can do myself to a proper standard!
@davideyres955
@davideyres955 20 днів тому
I guess the problem is they rarely come across good DIY as they assume all good installs are by sparkies and all the poor stuff is by DIY Dave (being a David it’s even more grating). Frankly there are some horrible wiring bodges I’ve seen and some of the crap jobs I’ve see. In my house done for the sake of speed rather than quality and maintainability are annoying to say the least. 1mm cable for the light that snaps because the copper has work hardened and not enough slack on the cables. However there are a ton of things I would not know like how to design earthing arrangement on a solar install with UPS functionality that are defo a job for a qualified sparky. The problem is people like you are probably a rare breed.
@robertallen2151
@robertallen2151 15 днів тому
Something a lot of you DIYers don't understand is insurance... it's the same argument when people go "I don't need a license to drive a car!" No you don't, but you do need one to insure that car for when you inevitably wrap it round a lamp post, cos you wasn't assessed to prove you are competent in the first place. It's all well and good doing it in your own home and thinking you know everything, but it's another thing to be doing it in other peoples houses when you could really cause some damage.
@robertallen2151
@robertallen2151 15 днів тому
Also if you did go to school for electrics mate, you'd know that regs are not retrospective and what was done in your 70's property at the time was probably not against the regs, so it's pointless using that as an argument😂
@martinwinlow
@martinwinlow 17 днів тому
What is the intrinsic issue with using otherwise adequately heavy (stranded) cable (flex) for wiring fixed/hard-wired equipment (rather than T&E)?
@tom314
@tom314 20 днів тому
A useful video showing your experience thank you, sadly I've seen most of those from electricians as well, including having my oven nearly go up in flames due to a loose connection and leaving live cables hanging from the ceilings (that hurt). Concerning the failure mode from an extension lead, I thought that's due to the cable not being able to shed the heat due to being wound up. I quickly calculated (so sorry if there's a mistake) that the inductive losses from that situation will be along the realms of 20W, (I think the inductor will be about 4mH), assuming that's a 25m 1.5mm^2 extension lead the resistive losses will be around 80W. (Quite happy to learn and be corrected, I mean this is in an educational learning sense not the standard YT comment way :) ). The other thing I've always done is to make sure the tester works before I rely on it to show a null result, but I use a multimeter, I don't know whether the tester you suggest has a built in check for itself.
@kaihendry
@kaihendry 20 днів тому
What clips do you recommend for securing cables?
@alanwood9804
@alanwood9804 20 днів тому
The correct size for the cable!!😃
@sausege777
@sausege777 20 днів тому
11th biggest mistake, calling it a plug when it’s a socket.
@GrahamDenison
@GrahamDenison 20 днів тому
It's a plug socket :)
@artisanelectrics
@artisanelectrics 20 днів тому
😂😂
@davepedantic
@davepedantic 20 днів тому
@@artisanelectrics I hope your emojis are aimed at the ludicrous term ‘plug socket’ Jordan. Plugs are plugs, sockets are sockets, there’s no such thing as a plug socket.
@jeremybarker7577
@jeremybarker7577 19 днів тому
@@davepedantic I suppose that a converter with, for example, a Schuko plug and UK socket, could be called a "plug [to] socket"
@bikerfirefarter7280
@bikerfirefarter7280 18 днів тому
Plug's socket. ?​@@davepedantic
@Cornz38
@Cornz38 13 днів тому
I had to do a lot of electrical work on my house and i took the time to search out quality sockets and sundries. I also made good any poor quality wiring i saw and replaced the choc-block with proper junction boxes. When tightening connectors with a screw driver, nip them up and then again a day later. You'd be surprised how much it will have relaxed in 24 hours.
@FiammaNera_
@FiammaNera_ 19 годин тому
I got a question! I live in Italy and I am currently studying Mechatronics, and I love working with electric and electronics, so I decided to re-make my cellar for working down there, and I had to re-make the electrical system, for having a better one. So I got cables of 1.5mmq that should reach into my cellar, and for my life saver i wanted a 2.5mmq cables, so I just used a mammut for changing the diameter. Now I got cables of 2.5mmq going insde there, and I was wondering: will my outlets work fine? I got 16Ampere one, and each of it there are 2.5mmq cables that are giving the power inside of them. I excuse myself for my bad english!
@PietroPasquero
@PietroPasquero 15 днів тому
"inductance is starting to build up" Speechless
@jol002
@jol002 13 днів тому
No inductance at all, because it concerns bifilair windings, which cause no magnetism. It's just that at 4A with a 0,75mm2 cable, it produces 7,47 Watt's, which will not heat the cable enough to destruct it, but... at 12A, the produced power will be 67,2 Watts, and this will kill the cable! Just try to unscrew a 60 or 75 Watt bulb as it has been on for a while --> VERY HOT! (formula's: r=(l*rho)/A --> (20*0,0175)/0,75= 0,467 Ohm. And: and P=I*I*r 4*4*0,467= 7,46 Watt, so is 12*12*0,467=67,2 Watt!
@CaspaB
@CaspaB 12 днів тому
A friend did a welding subject as part of a farming course c.1965. One participant asked why 2 wires were needed. "One for the volts, the other for the amps" said the instructor. (!)
@michael.a.covington
@michael.a.covington 20 днів тому
I've been told that the reason solder is not used in house wiring is that it would let go in a fire, with very dangerous results. By the way, Wagos have made it to the USA. I find them very useful on the test bench because it is so easy to make a good connection and then undo it non-destructively.
@cjs95
@cjs95 18 днів тому
This is why I don't like the tamper-proof/non-serviceable multi-socket Extension leads as these often use solder joints (to stop people re-purposing them I guess?) I had one recently in a school I work at (in the UK) where I took it out of service because the outer sheath had escaped the cord grip and it had an intermittent supply of power to the sockets. Out of curiosity, I broke it apart just to see how it had failed and it looked as if it had been getting a bit hot as the live connection was barely still connected. In the bin that went. The problem is, where it came from, the room (a faculty Staff room to be more specific) doesn't have many wall sockets so Staff have been using these extension leads where they want to plug in more devices. The other problem is that we have Staff who aren't particular about what they will plug into one extension lead ranging from any one or more of Fridges, Toasters, Kettles & Fan Heaters!
@ge2719
@ge2719 17 днів тому
i guess when you're house is burning down, you don't want it burning down a second time :P
@GretatheEvilGremlin
@GretatheEvilGremlin 20 днів тому
Yes, do be careful getting pulled off in the loft, insulation fibres get everywhere.
@CivilisedMuffin
@CivilisedMuffin 17 днів тому
If an extension lead is rated to 10A then it shouldn’t matter how many you daisy chain, you can’t exceed that 10A. This is a fear that comes from countries that don’t have fused plugs…
@deang5622
@deang5622 16 днів тому
You will eventually hit a limit which is caused by the voltage drop along the length of the cables.
@TheSynthnut
@TheSynthnut День тому
One of the craziest domestic instal horrors I found was figure 8 VIR with nails through the centre as clipping. Some of the nails had arc marks either side and the (Wylex off course) rewirable fuse carriers in the CU were so spattered with vaporised copper that they conducted enough without any wire to still show live on a high impedance tester.
@JustinHughesRoberts
@JustinHughesRoberts 20 днів тому
We had an immersion heater that had been wired in the house with 1mm cable. Fortunately we never used it as the boiler provided the hot water. I was only discovered when we had a board update.
@samanthabaines3578
@samanthabaines3578 15 днів тому
Wow, i genuinely never knew about the extension reel needing to be unwound!😮
@alhughes9698
@alhughes9698 20 днів тому
Gotta love doing number seven, just adds a bit of spice to the day.
@SemtexWarrior
@SemtexWarrior 15 днів тому
I'm a car mechanic and i can tell you there are countless cases of bad DIY wiring in the cars i see every day. Yeah it's "just" 12V but it can still cause a fire if you don't know what you are doing. One car i worked on had a custom DIY stereo install, fuse was in the back with the sub and the main supply cable was spliced inside the sill right at the drivers seat. The way they had spliced together the two cables was pretty unique: both ends stripped about 3-4cm and then just placed on top of each other. Three zip-ties held the two cables together at the overlapping splice and then two layers of electrical tape to finish it off. So if that crappy splice had touched the metal inside the sill it was routed through it would have instantly set fire to the car right next to the drivers seat since the fuse was in the back...
@jussikuusela7345
@jussikuusela7345 16 днів тому
If anything, the coiled up extension would be a bifilar coil where its inductance cancels itself out. If there was inductance, it would limit the current in the circuit, and BTW not contribute to the heat dissipation. A bifilar design is used in wire-wound resistors in HF circuits for the very reason of having minimal inductance. Like someone else pointed out, the heat builds up because it can't escape the tightly wound coil - even more so in a boxed reel extension. This is also why you should always fully unwind the cable of your vacuum cleaner for any extended period of operation. I knew a fledgling restorateur who bought a deep fat frier with two 3kW heating elements, both with their own 3x1,5 sqmm cables and SchuKo plugs. Correct rating and all, 16A per element - but he ran it off of a 10 meter extension. And he didn't unwind the extension either save for the two meters needed to reach the socket. He called me in to investigate why the breaker was tripping constantly and why there was a plasticky smell in the kitchen - I mean he called me after resetting the breaker no longer restored power to the frier. It took me an hour to get there, and when I investigated, the extension was still too hot to touch comfortably, and the overheat switch had tripped. For the time being I got him two shorter extensions that I ran to different outlets that I verified to be on separate breakers. BTW he would, after half a year, find that the restaurant is pretty much a money drain, and he quit after Christmas 2019. Right on time before ol' Rona (or the preventive measures taken) screwed everything up. The "lever Wago" is great in that you can undo it wire by wire without wiggling and jiggling, and you can mix solid and stranded wires as well as wire sizes. For small stranded wires in a comparably large screw terminal, end ferrules are good but not everyone has access to them when needed... My solution to it is to fold the strands back over the insulation and face them away from the screw so that the screw bites on the insulation, and the insulation squishes the strands against the bottom of the terminal. I've never had that fail.
@jgharston
@jgharston 17 днів тому
The "connect all the reds" things is why for a long time now I arrange wiring so that there is only one unambiguous cable at each outlet. All junctioning is done separetely from the outlets in junctions boxes specifically for the purpose.
@stephenkayll5241
@stephenkayll5241 12 днів тому
As an amateur, I am glad to say I knew all of the items you displayed, its an age thing, I'm 71 and was taught well by my father. To me some of the items were very obvious. Great educational video as usual.
@mufuliramark
@mufuliramark 15 днів тому
I’m a diy enthusiast and became one so many years ago because of what I saw ‘professionals’ do. Poor quality of work was the main reason but also the cost. Over 40 years I have become a jack of all trades, who has high standards way above what some contractors have. Just look at the quality of work put into new builds…. Shocking.
@RPBCACUEAIIBH
@RPBCACUEAIIBH 17 днів тому
I did the twisting solid, and stranded wires and swapped colors, and also didn't always clamp. Thankfully no issues. It's just double work, cause now I'm re-wiring everything. :)
@russrockino-rr0864
@russrockino-rr0864 13 днів тому
Stingers(leaving a strand of stranded wire sticking out), Shiners( stripping too much of the insulation off individual conductors. Running Romex in to a metal box or panel with out a plastic or metal romex connector. Open splices, cutting off the ground conductor on a romex cable, not tightening the wire nuts properly, not burying underground feeder cable to the correct depth, using too large of a breaker for their wire size, using extension cords for permanent wiring. These are common things that I see DIYers doing all the time. Thanks, Russ 29 years in the Electrical Trade from across the Pond.
@peters6601
@peters6601 17 днів тому
I once found a 2BA brass set screw in the fuse holder of a 13amp plug!! Happy days.
@gregmiller-breetz3368
@gregmiller-breetz3368 17 днів тому
Interesting to see how different DIY electrical projects are in the UK versus in the U.S. In the UK seems most of it is about messing around with plugs and cords, which really isn’t a thing here. I guess that’s because of the need to deal with the fused plugs etc. Here, I’m running house wire, installing receptacles and lights and the associated junction boxes, and new load centers.
@user-vs9pg1rj9d
@user-vs9pg1rj9d 20 днів тому
One thing common in bodge jobs especially around surveillance cameras is using Ethernet cables for power by directly wiring a few cores of the Ethernet cable to either a DC power supply or even mains voltage. The proper way to supply power using an Ethernet cable is to use a PoE injector / switch with a PoE capable device.
@GodmanchesterGoblin
@GodmanchesterGoblin 20 днів тому
And that works because PoE typically uses 48 Volts, and so the current flow (which is what drives heat dissipation) is only a quarter of that used with a 12 volt device for the same wattage.
@raychambers3646
@raychambers3646 17 днів тому
Had that on site Friday ," putting a light up in the kitchen easy " Monday " bloody fuse keeps blowing "
@As3th8r
@As3th8r 20 днів тому
We once had a LAN Party on a not uncoiled extensiondrum. At some point someone pointed out that the drum is quite warm after some safety tripped. That was hours into playing.
@countertony
@countertony 19 днів тому
This had me looking at the smart garage door controller (basically a wifi-controlled relay) I recently bought - all low voltage (5 Volts DC) so it's not a safety hazard as such, but the signal and ground cabling they use to connect to the main door control box is just a piece of random two-core flex with the outer sheath stopping well short of the device enclosure - no strain relief at all on the control cables, the USB power cables, or the door-edge sensor cables. I fear it's not long for this world.
@craigmck7271
@craigmck7271 20 днів тому
In reality why is there any issue daisy chaining 4 way type extensions, given, in the UK where this is filmed, each plug (including the primary extension) has a 13A max fuse, the most you could pull in the entire circuit is no different to it being on it's own. The fuse will blow and assuming the extension lead is suitably manufactured and tested, there should be no additional risk.
@robinbennett5994
@robinbennett5994 20 днів тому
I'm pretty sure that warning been imported from the US...
@nightcatarts
@nightcatarts 19 днів тому
The issue is that many of them aren't suitably manufactured and tested. People buy stuff online from wherever they can find it cheapest, and that results in a lot of really poor quality. How easy it is to find a partial earth pin in plugs for all kinds of things these days is sort of scary, & switched multi-gang extensions can be particularly gnarly with switches not rated for the mains or being spongy & audibly arcing. The fuse may eventually blow, but that doesn't mean you won't get heat build-up and scorching before it happens.
@craigmck7271
@craigmck7271 19 днів тому
@@nightcatarts fair point but if it’s cheap tatt then a single one is just as likely to go up in flames.
@nightcatarts
@nightcatarts 19 днів тому
@@craigmck7271 Very true, but that risk increases if the cheap one is first in a chain.
@monochromechaos9757
@monochromechaos9757 16 днів тому
13 amp fuse won't blow till you pull 26 amps or so through it, though. And the ring main will have a 30 amp circuit breaker. It's quite possible to get wiring running hot without the fuse blowing. If that wiring is enclosed somewhere - say run under furniture, tucked behind curtains - then the heat can't escape, and can build up to 'burning down the house' levels.
@wizard3z868
@wizard3z868 20 днів тому
The wire nuts can be a good connection if you pretwist the wires and if your going to solid to strand push the stranded in first than the copper than twist together. Enough practice you get used to it i prefer copper crimps and nylon caps (Buchanan and the 4 point crimp tool)but am coming around to wagos
@tonezoneuk
@tonezoneuk 17 днів тому
We moved into a bungalow and had electrocution and fire hazzards absolutely everywhere. Cooker point switch, earth wire not connected and flapping in the breeze. The hall light rose with 7 wires run into it and the wires just about fitting in and screw not able to hold them, and arcing. Of course those wires pulled out when moved. Lighting circuit protected by 32A breaker, and bodged connections were made in the loft using screw connector blocks, wires stripped back over an inch, bare parts of the wires insulated with single layer of insulation tape, then the whole lot twisted together, for whatever reason. A short and fire waiting to happen. Bodged connections under the floorboards, they cut into the ring mains and added sockets, connections made with lighting terminal junction boxes. One of the spurs went to a wall mounted RCD then to the garage and the cable buried under the ground. They ran out of wire and had a joint under the ground, so the RCD had tripped. So they bodged the RCD so it stayed on and the RCD was burnt & black inside, and stuck in the on position. Opened a socket in the kitchen and as soon as it moved forward, BANG. Unsleeved Earth wire shorted against live wire, all conductors stripped over an inch. Door bell button live. Connected to the primary of the transformer. The list goes on. I chose to scrap the lot and start a fresh with 4mm radial mains circuits with a seperate circuit for every room. Electrician checked for safety. I was fortunate to have experience with working with an electician wiring supermarket years ago, plus a good electrical background. Still had to update myself with new regulations in order to comply and for my work to be passed. DIY electrical can be very scary, and would definitely recommend anyone that moves into a new property, have their electrics safety checked.
@FirstDan2000
@FirstDan2000 20 днів тому
One common wire stripping method that makes me cringe, especially when professionals do it, is using croppers to ring and strip cable. I saw it recently.... I forget where.
@benskidmore6523
@benskidmore6523 20 днів тому
Seems incredibly common from what I've seen. I can't stand it!
@Aspie_Geek_UK
@Aspie_Geek_UK 19 днів тому
You forget the 1970's way of stripping wires, just look at most men's teeth who are in their 70's, there is a nice sharp gap between the front tooth and the next side one that's perfect for wire stripping! Manys the time I watched my dad strip wire with his teeth when wiring something up lol.
@FirstDan2000
@FirstDan2000 18 днів тому
Ah, the good old pvc days. Couldn't do that with modern xlpe stuff. It'd tear your face off.
@Aspie_Geek_UK
@Aspie_Geek_UK 18 днів тому
@@FirstDan2000 🤣🤣🤣 Too true
@retrozmachine1189
@retrozmachine1189 15 днів тому
@@Aspie_Geek_UK Not 70 but yep I have the gap and a damaged tooth to boot. Stripping wire with your teeth is something only real me do. Real stupid men.
@pompeymonkey3271
@pompeymonkey3271 17 днів тому
Is the coiled extension lead really an induction problem, or just that the normal amount of resistive heat cannot dissipate? Or a bit of each?
@deang5622
@deang5622 16 днів тому
Resistive heating only. There is no net magnetic field created by a coil of mains cable as there are two currents passing through two coils in opposite directions. No net magnetic field, therefore no inductive heating.
@iAMxplosiff
@iAMxplosiff 9 днів тому
Got called to a drive through sign not working. Has been installed for over a year. The underground was compromised and decommisioned. The mains feeding the first drive through sign (before it looped off) was an extension lead with the ends cust off instead of proper cable.
@nekosarantango865
@nekosarantango865 15 днів тому
When doing some renovation work we discovered the previous owner had the whole utility room powered from the boiler spur 😮😮
@chimpyd
@chimpyd 20 днів тому
here in australia and new zealand it is standard to twist wires together and put in a screw connector.
@robinbennett5994
@robinbennett5994 20 днів тому
British electricians hate that when they have to isolate sections of a ring main to try to find a fault.
@davidbrooks9576
@davidbrooks9576 19 днів тому
We don't have ring circuits in Australia.
@chimpyd
@chimpyd 19 днів тому
@@robinbennett5994 completely agree. I think we should use wagos
@GuyChapman
@GuyChapman 15 днів тому
My worst DIY mistake was putting a bolster down between two boards and cutting through a cable that had been notched into the joist. Rookie error! I recently completely refurbished my house, and made sure that all cables went through holes in the joists. But then, my Dad was an ex-sparks who taught electrical apprentices - he *never* notched a joist.
@pgrimshaw62
@pgrimshaw62 20 днів тому
The coiled up flex also applies to vaccum cleaners.
@deang5622
@deang5622 16 днів тому
Applies to hair drier cables that haven't been unwound too. Applies to electric kettles whose cables haven't been unwound too. I see a pattern....
@belperflyer7419
@belperflyer7419 18 днів тому
Those wire connectors at the beginning were called Screwits. We had a boxful in our shop back in the 40s/50s - and they were porcelain! Dad wired several houses pre-war using them - houses which had no mains originally. One of the most likely scenarios for apparently neutral wires being 'live' is where there are two-way light switches. I did once move our electricity meter becase it was in the way of a new ceiling in our very old house. I cut the company seals and was very careful :) If something IS live then try to use one hand if possible. BTW, the extension cable heats up due to good old resistance rather than inductance - watts (heat) is proportional to current squared and to resistance directly. I'm not an electrican (I ended up an electronics engineer) but I've been wiring electrical things for 70 years. The worst thing I saw was a mains plug wired with bare wire OUTSIDE the plug. The customer complained his maiins fuse had blown - hardly surprising, the three wires were fused into a solid bar!
@rfitzgerald2004
@rfitzgerald2004 4 дні тому
Speaking of bell wire, I've been known to use coax in the past 😂 of course I understand the risks and took precautions, it was just what I had at the time for a temporary fix
@paulstubbs7678
@paulstubbs7678 18 днів тому
Best one I've found was a doorbell transformer wired into the back of an outlet using figure 8 shielded audio cable, he just mashed the inner and outer of the shielded wire into one conductor on both sides, effectively turning it into twin flex. The worst part was her was a licensed electrician, and maybe worse, he did this to his parents house! (that I then bought) I bet there is some other 'greats' yet to be discovered in this house.....
@ralphtaylor5328
@ralphtaylor5328 17 днів тому
Not strictly a DIY wiring error in the theme of this video is not fully unwinding the cable on vacuum cleaners that essentially have internal extension lead. The Henry family is a popular example.
@m.s.8112
@m.s.8112 13 днів тому
No. 10: Effectively, this is no inductive coil. The magnetic fields compensate each other as the current in live and neutral wire flows oppositely. it's all about losses due to the copper's resistance.
@markpapp8784
@markpapp8784 16 днів тому
Glad to know nothing I've done features in your list. I was wondering if you were going to include #10! Re. #10: some vacuum cleaners (Henrys, etc.) coil excess cable inside them...
@timsoft3
@timsoft3 13 днів тому
screw fittings don't go loose due to AC (as opposed to DC), it is thermal expansion and contraction when power is turned on and off which can cause the screws to loosen. if the screw is not tight enough to start with, you can get arcing which will excelerate this and potentially cause a fire. I've seen speaker wire used instead of bell wire, which is also really bad, as apart from the lack of earth or secondary insulation, the primary insulation is usually not heat resistant and easily melts, exposing the wires. I've also seen "professional installation" wire power supply colour changed between consumer unit and switch from red to blue, or white, or red making it impossible to rely on the wire colouring. As has also been commented, the coil extention wire overheats because of lack of air cooling, not inductance. As the live and neutral is in the same flex, flux will cancel out, as the current is going in opposite directions in the same flex. The conductors are the same size and will have the same voltage drop accross them but in the opposite direction in a length of flex. (This is why a clamp current meter doesn't measure current when put over flex containing the live and neutral. it uses electromagnetic flux to measure current)
@marymadigan9707
@marymadigan9707 20 днів тому
Very nice good advice 😊
@Drewtheelder
@Drewtheelder 18 днів тому
Famous last words, "don't tell me how to wire a plug".
@chrisb8362
@chrisb8362 20 днів тому
Oh Yeah, I've seen them all. The most common is the small outlet shops that use the cheap CFL lights strung together with twin flex and running the length of the shop. Plugs in these shops are also a mess as the main DB (which is scary to begin with) is looped to multiple other DBs on sections built on to the original building. Lastly, fast food outlets UUHH the supply to the appliances is absolutely horrendous very dodgy covered in old cooking oil mostly incorrectly positioned to begin with and hopelessly overloaded.
@user-il7xt9ml2q
@user-il7xt9ml2q 20 днів тому
The heating of the extension is due to resistance not inductance. Yes, essentially it could be considered a big inductor but and inductive reactance is quasi resistive and doesn't actually create any heat.
@Electronzap
@Electronzap 20 днів тому
Good info.
@tm2204
@tm2204 17 днів тому
Excellent video 👍
@owenoneill5955
@owenoneill5955 17 днів тому
I am in Bulgaria..all these faults are standard practice here. All the wiring in my house refurb is heat and fire resistant, When the '' technician'' from the elecricity supply company came to check the installation before connecting the house to the meter box, (3 phase, 385 volt supply) he asked me what all the ''fancy orange cable'' was for. 😊
@MyProjectBoxChannel
@MyProjectBoxChannel 14 днів тому
If you fuse down to 13Amp from a 32Amp ring, with a fused spur, can you have sockets wired on 1.5mm twin&earth (after the fuse?) 1.5mm is good for 15Amp, or even 18Amp, for a short time. So with the 13Amp fuse protecting the 1.5mm cable, it should in theory be fine? I know that you will always do it in 2.5mm , but it should be ok on 1.5mm.
WORST DIY ELECTRICS I'VE EVER SEEN! 🤯
22:52
Artisan Electrics
Переглядів 627 тис.
5 Mistakes Everyone Makes Changing Sockets ❌
11:44
Artisan Electrics
Переглядів 450 тис.
Парковка Пошла Не По Плану 😨
00:12
Глеб Рандалайнен
Переглядів 12 млн
SMART GADGET FOR COOL PARENTS ☔️
00:30
123 GO! HOUSE
Переглядів 20 млн
The Most MISUNDERSTOOD Feature On Your Drill
13:41
LRN2DIY
Переглядів 3,3 млн
What electrical work are you allowed to do in your own home?
10:39
Proper DIY
Переглядів 612 тис.
Carrying out an EICR - an overview of what we do!
12:14
Justin Bucknell Electrical Ltd
Переглядів 12 тис.
Customer SHOCKED by our pricing! - Are we too expensive?
13:17
Artisan Electrics
Переглядів 162 тис.
Why 50% of All Crimp Connections Fail - Up or Down?
4:57
Silver Cymbal
Переглядів 954 тис.
5 CLEVER Electrical Tricks Everyone Should Know
11:06
LRN2DIY
Переглядів 3,4 млн
Why Circuit Breakers DON'T Protect People (electric shocks)
18:23
The Engineering Mindset
Переглядів 603 тис.
OUTSIDE CONSUMER UNITS...A CONTROVERSIAL TOPIC!!  HERE'S MY VIEW.
11:52
SOTA Electrical
Переглядів 8 тис.
How America RUINED the world's screws! (Robertson vs. Phillips)
9:46
Stumpy Nubs
Переглядів 666 тис.
This Is Why Builders SHOULDN'T Do Electrics! 🫣
19:59
Artisan Electrics
Переглядів 59 тис.
ИГРОВОЙ ПК c WILDBERRIES за 40 тысяч рублей
30:17
Ремонтяш
Переглядів 487 тис.