DIY Multi-Zone Ductless Mini Split AC & Heating System | MR Cool Install 2021

  Переглядів 911,039

Modern Builds

Modern Builds

3 роки тому

How to install the MR COOL DIY Multi Zone Ductless Mini Split unit. I took out the old Window Unit poking through my wall and replaced it with this efficient new system with 2 air handlers. Is it worth it???
Head to squarespace.com/modernbuilds​ to save 10% off your first purchase of a website or domain using code MODERNBUILDS
Materials and Supplies:
MR COOL Multi-Zone: amzn.to/33GXoOX
MR COOL Single Zone: amzn.to/3ybARYx
Stucco Anchors: amzn.to/3y9jJm9
Service Switch: amzn.to/3bu4MS6
Marble Chips: thd.co/3fgNl8w
Concrete Bags: thd.co/3fkb0ot
Some other videos that helped:
DIY Creators: • How To install Ductles...
April Wilkerson: • DIY Ductless Mini Spli...
Crafted Workshop: • DIY MULTI-ZONE Ductles...
Komar Project: • How to Install a DIY M...
Maker Brand Simple Finish is back in stock!! If you're interested in supporting or just checking it out, link is here: makerbrandco.com
This installation was surprisingly easy. I've seen quite a few tutorials showing how to install a mini split system like this and having those resources were really helpful to me.. .not to mention getting help from Josh and Jeremy. I would totally recommend a DIY mini-split installation rather than the cost of a traditional HVAC install... and check out the specs on these MR COOL parts I used.

КОМЕНТАРІ: 911
@jeremyh172
@jeremyh172 9 місяців тому
Super simple and anyone can do it, all you need is two hvac techs and one electrician.
@CS-yp7md
@CS-yp7md 3 місяці тому
Facts 😂😂😂
@damanorelse
@damanorelse 3 роки тому
I've watched a half dozen different youtubers install AC, and I could watch a hundred more.
@Benji_4
@Benji_4 3 роки тому
Heat pumps arent really a new thing. In hotter climates heat isnt used much so having electric heat is not that bad. Gas is much cheaper in most states, but obviously he doesn't have gas there and you cant get a split with a furnace anyway.
@specialestness
@specialestness 2 роки тому
@@Benji_4 gas used to be quite cheap by me but not so much anymore. Went from a total of $.24/therm to now nearly $1/therm.
@parzdiver
@parzdiver 3 роки тому
“I won’t be doing a video because I have no idea what I am doing.” Um... isn’t that what most of your videos are? Love them all!
@KorraTheFrenchie
@KorraTheFrenchie 2 роки тому
Kind of what I was thinking. Also it’s the best time to do a video if you’re being authentic about yourself and your channel.
@iKarrott
@iKarrott 3 роки тому
Heat pumps are the future. Technology Connections would be proud.
@stevejeffrey11
@stevejeffrey11 3 роки тому
can they handle cold winters in Alaska, Canada? how much power do they use for off grid applications
@kyleg3588
@kyleg3588 3 роки тому
@@stevejeffrey11 air heat pumps, depending on the brand, function well to about 0°F, but some still work below 0. For colder climates, there are in ground heat pumps that use pipes and geothermal heat.
@CentralNintendo1
@CentralNintendo1 2 роки тому
@@stevejeffrey11 Modern heat pumps can work well in the cold, however at some point they will reach the same cost effectiveness of regular electric baseboard heaters. So I would not recommend them for alaska in the cold days, but maybe the warmer days. It also depends how expensive your fuel is vs electric heat.
@HollywoodF1
@HollywoodF1 2 роки тому
You may be able to use heat exchanger piping installed in the ground below the frost line. I haven’t researched it but the ground is used as a heat sink in this manner in hot climates. Also if you have access to a body of water it will be much warmer than the air. But you can’t beat the electrical efficiency of these systems. The power inverter technology they run makes sure they’re running at the exact right level instead of the on and off of non-invertered systems.
@misdemeanor7083
@misdemeanor7083 3 роки тому
I'm about to move into a semi fixer-upper house and these videos are very motivating. Knowing I could get something like this done with little experience and a weekend's worth of work is awesome. Thanks man!
@dangeroreilly2028
@dangeroreilly2028 9 місяців тому
I think I'd paint the line covers the exterior wall color, to help them blend.
@ebonijohnson4442
@ebonijohnson4442 3 роки тому
I live in Guam and 90% of the homes are built with split ac units to help keep electricity costs down. I love them!
@robertberin4872
@robertberin4872 2 роки тому
👍 10:17. Oil is going to pool up because you coiled the excess vertically. You should've elevated the condenser and coiled them horizontally.
@wwgbert
@wwgbert 3 роки тому
This looks great, one tip only, please don't shut off your living room at night to "save" on cost. What happens is the rest of all the mass heats up and the system when you turn it back on has to over compensate so it spikes to get everything to your designed temp. Trust me on this one, either you really want a system that runs like a "taxi" or one that runs like a car on the highway. Taxi's start and stop, highway driving will always be better milage and WAY LESS ware and tear. I really do hope you see this, I have been doing this HVAC / building science for 20 plus years.
@adamradley4407
@adamradley4407 3 роки тому
I would also add that most require at least 5" clearance from inside wall. When you wrap your last newer bundle the drain should be on the bottom portion to allow for better draining and prevents airlocks. I am not sure where you are but anywhere the temps drop below freezing you should install the unit on a stand so condensation on the outdoor unit during heating won't form a giant block of ice at the base of your unit on a pad.
@wwgbert
@wwgbert 3 роки тому
@@adamradley4407 I’m in the PNW , I have seen that happen up in the higher elevations areas by Mt Hood. Most people here live at around 500’ above sea level and the winters are generally mild, winter design temp is 42, summer is 83. While we do occasionally have lower and higher temps you will see ice dams on ground mounted units. I prefer exterior wall mount for many reasons, easier access to work on, lower maintenance and cleaner look. Good tip though!
@bradleydavidgood9316
@bradleydavidgood9316 2 роки тому
I like the rough texture of the cement pad! Great job on everything, looks great. Thanks for the video!
@rapturebound197
@rapturebound197 2 роки тому
I am definitely going with a Mr. Cool system. I own 2 homes that I am remodeling and I've decided the mini-split heating & AC units are the way to go. I like the flexability of controlling different zones of the house separately. Thanx for the installation video..I have watched several of them on the mini-splits and yours was very well done. 👍
@WillieStubbs
@WillieStubbs 2 роки тому
LG makes a mini split with ceiling mounted units.
@rapturebound197
@rapturebound197 2 роки тому
@@WillieStubbs hi Willie..the reason I prefer the Mr. Cool system is I can install it myself with their pre-charged refrigerant lines.
@jaandel1
@jaandel1 Рік тому
Can you share more info about you electricity bill
@trueadrn
@trueadrn 3 роки тому
3:19 "no idea what i'm doing" -Those are the best videos!!!
@gratitude6573
@gratitude6573 2 роки тому
Place rubber absorbing pads under the outdoor unit feet before screwing to concrete. Helps absorb vibration and stop concrete rusting the feet over time. These have been the staple air-conditioning systems in Australia for decades. nice to see the USA catching up.
@Zhiperser
@Zhiperser 9 місяців тому
Catching up? Most American houses already have built in Central Air conditioning to each room. These mini-splits are a great replacement for window units, but window units are only standard in old and/or run down buildings. Typically those in cities that didn't need it for very long.
@justinc.2656
@justinc.2656 3 роки тому
I did a multi room unit in northern California, it was awesome, the dehumidify really was all I needed 90% of the summer it was great to have the option to keep rooms at different temps. (one thing to note is you cannot mix heating and cooling a the same time.)
@rrsonic2913
@rrsonic2913 3 місяці тому
so you cant have one head unit in one area on cold, and one on hot ? thanks for info as nobody has ever mentioned this in any video
@justinc.2656
@justinc.2656 3 місяці тому
@@rrsonic2913 - just one caveat is that is per condenser. If you have two separate units they can operate independently but if you have one unit that supports 4 rooms then it can run the fan, dehumidify, along with heating OR cooling in just the rooms you want.
@jessegandarilla4472
@jessegandarilla4472 3 роки тому
I just installed mine in my living room last week. I now have to install my multi-zone ones throughout our bedrooms. This video was super helpful because I wasn't sure how to get one of the air handlers in one of the rooms because there isn't enough room on the exterior wall(giant window). Your video showed something the rest of the videos haven't, and that is bending the lines of the air handler the opposite way they came in. I did not know you could cut out that plastic piece if you needed too. This was amazing to know. I am less stress and more confident in doing this. You have a new subscriber!
@patomex76
@patomex76 2 роки тому
Question? How much you spend on it? we have a house with 3 bedroom leaving-room, dinner room kitchen and a small office& Landry room.
@jessegandarilla4472
@jessegandarilla4472 2 роки тому
@@patomex76 our house is roughly 1,700 sq ft, I installed a total of 4 air handlers. Our living room is by far the biggest room we have so I bought a unit with just 1 air handler and condenser. It was an 18000 btu and it cooled it off pretty fast. I then installed a unit in each bedroom(3) and they also work fantastic. For those I bought a 27000 btu which is 9k per unit. I spent a total of $4100. It was less because I’m a pro extra member and got a big discount or else it woulda cost around $6000
@jaandel1
@jaandel1 Рік тому
@@jessegandarilla4472 how its your.bill having ac mini split unit installed.. I have electric basebard heater 220v. It is expensive in winter season looking for install this unit. I already run the wire( renovation) for this time unit in the future but I not sure if I actually save or not in my electricity bill.
@jessegandarilla4472
@jessegandarilla4472 Рік тому
@@jaandel1 our highest bill came this month because we’ve been running the heater all day almost non stop. It was $200. Our furnace went out and that’s why we’ve been using them a lot this past month. Our bill usually averages between $80-$100.
@mohedaicebear
@mohedaicebear 3 роки тому
this is somehow my 6th UKpostsr to put in a split ac. and I watched all of them theses arnet even informational anymore I'm just enjoying the show
@tdmmcl1532
@tdmmcl1532 Рік тому
the gravel and wooden frame is a great touch. As a landscaper it's always a much easier job to maintain the lawn near the hvac systems that have been designed for not just aesthetics but practicality and safety. good job
@ModernBuilds
@ModernBuilds 3 роки тому
Big upgrade from the window unit I used for the last couple months of summer last year. Mini-split units are becoming more and more popular and I wanted to see what all the hype is about.. definitely way more quiet and convenient, plus it heats as well as cools. I'll post an update after this summer to talk money and savings! What kind of savings have people seen switching to ductless systems?? I'm curious to compare!
@raymondpaguia4695
@raymondpaguia4695 3 роки тому
try making a shroud cover for the condenser to keep it protected from the sun thus keeping it cooler as well
@guerisfone
@guerisfone 2 роки тому
Amazing job on your install, a couple of things to keep in consideration. If it snows where you are then you should put it on a stand because those units condensate in the winter and defrost. The line set should be on a spiral not on a coil, because coils may trap oil. Curious to know how efficient and economical your unit is. Great video.
@travisgaylor6830
@travisgaylor6830 2 роки тому
You may run into issues in a year or 2. I noticed you installed the linesets with vertical loops coiled up behind the condenser. That’s a big no no. Your causing an oil trap by doing that, this not allowing all the oil to return to the compressor. This will cause problems with the unit, and ultimately shorten the life expectancy
@ozzya7887
@ozzya7887 2 роки тому
@@travisgaylor6830 Good point! Because the lines are provided at set lengths and could not cut them, how would you remedy? E. I. Coil them on a spiral downwards?
@allianceofvengeance
@allianceofvengeance 2 роки тому
@@ozzya7887 they could have cut them and soldered them back on.
@mohedaicebear
@mohedaicebear 3 роки тому
I was seriously surprised how nice you dressed it up. if that was in my front yard I wouldn't mind
@vaioskaliakoudas6388
@vaioskaliakoudas6388 3 роки тому
Using the draining water from the indoor units to water plants is an amazingly smart idea
@DocNo27
@DocNo27 2 роки тому
"... I probably won't do a youtube video because I have no idea what I'm doing..." Aw - those are the best videos! Nice job. Minisplits are indeed very nice. If you live in an area with high humidity there is nothing better for dehumidification since the vast majority of them are variable speed and they can optimize for dehumidification.
@TheHarryChanne1
@TheHarryChanne1 3 роки тому
It's also worth mentioning, code in some areas will require in offset from the property line. It's not worth risking a notice from the city telling you to move the unit, so check your local regulations.
@madzabinga8382
@madzabinga8382 3 роки тому
Been wondering where you've been. Love your videos!
@sarahphillips8884
@sarahphillips8884 2 роки тому
omg you have emboldened my husband and I! I think we'll try this!!
@BigTuna667
@BigTuna667 3 роки тому
Wow having the condensation water plants is sooo smart makes me want to try that at home
@mattsbrute
@mattsbrute Рік тому
Just to clear up the never ending question I keep seeing. I've installed both styles. DIY and standard mini splits. The DIY units have Freon pre charged in the lines with sealed connectors. The vacuum is already pulled on the compressor side. When you open the valves where the lines attach to the outside unit it draws the Freon in from the pre charged cooper lines and your done. Run unit 5 mins in heat and cool cycle and your good to go. The standard units have Freon already in the compressor side but the copper lines have to be built so they will have air in them. They need to have a vacuum pulled and you need the little special connector to attach your gauges. Its like $12 I think. Your pulling the vacuum on the lines and inside unit for I think 30 mins at whatever pressure. The inside unit will make a little hiss sound when you take the caps off which is good. They pull a draw on it and the hiss means it has no leaks. I don't remember exact numbers but its in the book. AC guys know off top they're head. The DIY units have worked perfect for me so far after a few years. The standard units have been perfect also. There is no difference in the cooling abilities between them.
@hansarbelaez
@hansarbelaez 2 роки тому
I installed MRCOOL mini split units (1) 24k and (2) 9k and I cannot be more happier, this last winter I use way less oil and compare with the electricity used i got big savings, now in the summer I’m using so far the dry mode and it cool all the areas so easy, super energy efficient machines, but I think by getting the units separate will save you more than having a multi zone condenser for all the air handlers, individually you get more seers but Multizones less seer therefore less efficiency and more power consumption……overall great investment
@russellu5266
@russellu5266 Рік тому
what is the noise level of the inside units? Is it acceptable for bedroom use?
@MrTom38ncalif
@MrTom38ncalif Рік тому
The MrCool units are top notch. Just make sure you dont put any additional pressure on the lines when installing to the condenser (the outside unit with the fan). I have 2 of them and couldnt be more happier. Plus the super efficiency is a bonus as it saves me tons on my electric bill . Overall great video!!
@JoseRodriguez-pn9hx
@JoseRodriguez-pn9hx Рік тому
How much did you save on your electric bill?
@jaandel1
@jaandel1 Рік тому
How much do you save did you use heatpump
@tangoseal1
@tangoseal1 8 місяців тому
@@jaandel1 My 2 ton Pioneer Minisplit cost me about $1.00 a day or less to run full tilt. I have a 22 seer unit.
@MakingMadeSimple
@MakingMadeSimple 3 роки тому
I remember back in the day (on the Modern Maker Podcast), you'd mention that your long-term dream was to take on a bigger project, like a house. It's crazy to see that come true! Great content, as always, and killer edits! (still watching the video, just wanted to get my comment in early, haha).
@ModernBuilds
@ModernBuilds 3 роки тому
Thanks a million brother!! Been a Long road but I'm pumped to have everything moving in the right direction... I'm demo'ing and remodeling the bedroom starting next week and can't wait to go room to room!! 🤙🏼🤙🏼
@MakingMadeSimple
@MakingMadeSimple 3 роки тому
@@ModernBuilds You're crushing it man! I'm sure there are TONS of viewers like myself that have followed along for a while, and are super excited about those future projects!!!
@TJCooney
@TJCooney 2 роки тому
DIY as long as you have some HVAC tech’s with you
@midntdlight4782
@midntdlight4782 2 роки тому
Seriously huh lol. Wait till EPA pays them a visit
@williambaker9506
@williambaker9506 2 роки тому
No kidding… 2 hvac techs, Free System, Halfassed Concrete Slab job.. Wtf Mike, why even bother?
@neal5186
@neal5186 2 роки тому
@@midntdlight4782 why would epa pay them a visit? they aren't venting any refrigerant
@biancab310
@biancab310 2 роки тому
😂😂😂
@Aviator168
@Aviator168 2 роки тому
The HVAC techies were there for the electric work. I am sure MrCool has done all the legal work for their DYI systems.
@origtex
@origtex 2 роки тому
A) Cool Air provides rubber dampening pads for each of the four corners wear you bolt it down. They should have been used. Vibration on that hard pad will be tough on the unit. B) You can't water things with the condensation. The water is full of impurities and can kill plants. C) The key to this install was the great electrician.
@FabiusMaximus1000
@FabiusMaximus1000 2 роки тому
How is the water full of impurities?
@MichaelWilliams-ro9bm
@MichaelWilliams-ro9bm 2 роки тому
I agree. Plus, mine put about about a cup of condensation per month. Not worth the effort to water anything.
@enriquebahenarodriguez8573
@enriquebahenarodriguez8573 3 роки тому
Your videos are great, wish I had the confidence to tackle projects like these myself lol.
@axelgiovanni1031
@axelgiovanni1031 2 роки тому
It’s simple just hire 2 Friends (aka) HVAC technicians like this guy did and bam you have all the confidence you need to tackle the project.
@deanlerch1334
@deanlerch1334 2 роки тому
Good job dude. I'm getting now. Been waiting for a multi zone unit
@DIYBuilt
@DIYBuilt 3 роки тому
Great video Mike, I think the concrete pad looks fine being un-troweled. Nice work on the install.👍
@DrDonO
@DrDonO 2 роки тому
Finishing TIP for m.split installations: When finished, PAINT to Match = Paint all your 'additions' attached on the exterior wall(s) using same-color wall paint of your house. Then they will blend in so that exterior wall will look a great deal less industrial. Include painting: LineSet Covers, conduit and disconnect box... can even paint wiring. Note that the gray on the disconnect box is gray PRIMER paint - these are meant to be 'painted in' in order to match surroundings. (Same is true for your inside Circuit Breaker Panels - no reason to leave them gray in the middle of a white wall) -Cheers
@robertberin4872
@robertberin4872 2 роки тому
Did that today. Can't even tell its there now.
@justingilbride6661
@justingilbride6661 11 місяців тому
Just don't goop the hardware with paint lol God forbid you ever have to service it spending 20 mins just to chisel all the paint out of your hardware 🤣
@D.N.R.911
@D.N.R.911 Рік тому
Dude, this set up was really slick, thanks for sharing.
@tangoseal1
@tangoseal1 8 місяців тому
The only thing you are missing is a surge protector for your minisplit. You should install a Ditek DTK120/240 surge protector on your cutout switch so that in the event a lightning strike or power company surge happens your sensitive electronic control boards in the minisplit aren't toasted.
@HollywoodF1
@HollywoodF1 2 роки тому
I realize not every tiny step is filmed- did you air-seal the interior holes in the wall and water-seal the exterior holes under those flanges?
@DaruDhillon
@DaruDhillon 3 роки тому
Nice work on the install Mike, looks great! 👍🏽
@davidj7516
@davidj7516 Рік тому
Thank you very much for your time and posting. Great job. I haven't decided on two 12K BTU systems or one 24K BTU 2 Zone system for a mobile home w/ 840 sq. ft. Thanks again.
@chainsawhero5
@chainsawhero5 2 роки тому
Awesome video. My OCD now needs the follow up video where you repaint the wall and patch the outside stucco lol
@plasmac9
@plasmac9 2 роки тому
"DIY." Guy hires an HVAC company to do the entire install.
@hariranormal5584
@hariranormal5584 2 роки тому
If you see a channel with LOT of subs, sponsored by a shit company like Squarespace, then 95% of the time its just pure BS.
@HalProctor
@HalProctor 2 роки тому
if you read up on any of the mini splits, they require the lines to be installed under vacuum. They also state if you do not use a licensed AC pro, all warranties are voided.
@baddog2029
@baddog2029 2 роки тому
@@HalProctor Not on these.
@marksmanaz
@marksmanaz 2 роки тому
@@HalProctor Then don't label the video DIY
@jim2lane
@jim2lane 2 роки тому
@@HalProctor the Mr Cool units apparently do not come with that requirement - a bit different than the rest. My Mitsubishi unit definitely required a licensed AC pro as well.
@f4fake22
@f4fake22 2 роки тому
My Mr. Cool mini split is going on 2 years strong, not a single problem with it. Solid unit for heat and A C.
@allen35315
@allen35315 Рік тому
Can you share what the wattage draw / electrical costs are?
@f4fake22
@f4fake22 Рік тому
@@allen35315 cannot provide information, my entire house is electric everything. I bought the 24k unit 19 seer for a 1100ft SQ house, I can heat the house up 12° in about 6 minute's in turbo heat mode though....it's glorious. My refrigerant lines did fail though. Poor design by Mr. Cool, the first couple feet were braided and rotted/failed, I replaced the lines and refilled with 410a. It looks as if Mr. Cool corrected the "braided lines" and are now copper from outside unit to indoor unit. I paid 700 bucks after a 800 dollar rebate from my electric company vs. 8000 dollars for a Mitsubishi unit installed.
@marlaplunk2833
@marlaplunk2833 Місяць тому
@@f4fake22 Do you have just the one air handler installed in that 1100 sf house? How do you get warm/cool air in to the smaller rooms like bathrooms and bedrooms?
@f4fake22
@f4fake22 29 днів тому
@@marlaplunk2833 just one, I went with the 24k unit so it's overkill. Back bedrooms still need to use baseboard heat on occasion.
@mikecolo2158
@mikecolo2158 3 роки тому
Great job as always Mike. Please do share with us the energy comparison after the summer. I am very interested. We have a large famiy room addition and since we are on a slab there isn't any ductwork for heat or AC. We have an old stand alone heater and have lived without AC in that room since we bought the house 3 years ago. One of these Mr. Cool units might just be the ticket. How is the finish on the tub holding up?
@humediy
@humediy 3 роки тому
great video. One of the best I've seen about mr. cool.
@MCabossart
@MCabossart 3 роки тому
I'm excited to see how this build holds up, and the savings it could bring you! The simplicity of install seemed so well designed, and I will definitely be checking out this company. One thing that concerned me while watching your testing of the connections with snoop (soapy water). It's fine when those lines are positively pressured like they were, but if you ever run into issues and are troubleshooting the unit, be sure to never snoop a section of refrigerant line you have a vacuum on. If you have a leak and the line is negatively pressured, you'll ruin (and need to replace) the filter dryer, and could possibly corrode the inside of the tubes and damage the compressor. Anyways, great video as always, and I hope that you do show the stucco work!
@theloneviking9145
@theloneviking9145 Рік тому
Great tip!
@simonking978
@simonking978 2 роки тому
Here’s a tip on the concrete: after about 2 hours setup time on a pour the size you did, use a rasp to knock down the rough spots and essentially you have a smooth sanded finish before it hardens. Use a level to span across the forms as you go to check for high spots. Sweep off the dust when it’s cured. Good to go.
@johnbarker5009
@johnbarker5009 2 роки тому
I hadn't heard of this approach before.
@MsChops123
@MsChops123 Рік тому
Super late here lmao, but where i live most builders spend at least a couple minutes hitting the boards firmly with a hammer o something once they poured all the concrete when building this kind of slabs and bases. This removes the air bubbles and gaps inside the mix and some water go to the surface, so it has a better finish. Isnt this done in America??maybe the concrete is just so different?
@donnie2533
@donnie2533 3 роки тому
Great video glad you posted been waiting
@intricate3
@intricate3 3 роки тому
Mike, LOVE the intro music!
@Shizz1000
@Shizz1000 3 роки тому
I hope you decided to record the patch job. We wanna see it
@berated4541
@berated4541 2 роки тому
I know you had some Pro's come and help you but just a couple things to keep in mind (From another Pro) - Those communicating and power wires to the head unit are not UV rated, you really want to run those in some type of shielding (i.e. Sealtight or Liquidtight) - Those temp guns measure surface temp, not air temp, which is different and key when trying to gauge a true temp split. - Hooking up gauges to mini-splits to assess sub-cool and super-heat is pointless unless the system has a "charge" mode which can be enabled to force the system into 100% capacity One of the reasons these inverter mini-splits are so efficient is because they almost NEVER run @ 100% capacity. And if it's not then you have Accumulators and or Receivers that store refrigerant and release it back into the appropriate circuit/ working in conjunction with the metering device (Usually an EEV) to maintain a target SH. These systems seldom run long enough, and at a consistent enough capacity, to accurately read SB or SH. This is why a lot of the ductless mini-split systems don't even have a high side service port, just a low side to add refrigerant, which is only necessary if the line set is over a certain length, and in these cases, the added charged is calculated and weighed in via length of line set. ** I say high side (Discharge) and Low Side (suction) out of habit. On this system the EEV is in the condenser so both lines are technically "Low pressure" (This is why both must be insulated) But as a reference point it serves its purpose. ** On a side note, please do a one year update! I only ask because I myself have replaced at least a half dozen of these MRCOOL with name brand ductless mini-split systems do to these MRCOOL's failing. All for loss of charge, but in different areas of the refrigeration circuit.
@evoltap
@evoltap 2 роки тому
I'm not a pro, but I have installed two of these (single zone) Mr Cools. One of them has been trouble free for about 3-4 years. The other one had multiple problems, and I was sent warrantied replacements for both the wall unit and the condenser. Without the 5 year warranty, I would not recommend these. As long as you're ok maybe having to swap them out in those 5 years, it's hard to beat the deal.
@syclone1012
@syclone1012 Рік тому
I just installed one at my Barndo, can I have a licenses HVAC guy maintain / clean it every 6 months? Would that be advisable or do-able ?
@berated4541
@berated4541 Рік тому
@@syclone1012 You can. But they are fairly maintenance free when installed correctly. Keeping the filters cleans at the head unit and the condenser coil clean is really all you need. Other than that the only other common failure on head units are the condensate pumps(not used on every install/set up) There’s also certain manufacturer specific issues that involve electrolysis but most of those issues have been addressed by now.
@majahanson311
@majahanson311 2 роки тому
Those yellow magnetic stud finders are the best. Cheap an effective
@tomasfranco9438
@tomasfranco9438 2 роки тому
very nice , I am ready to do this on my guest house .thanks for the video.
@BillPairaktaridis
@BillPairaktaridis 3 роки тому
Awesome project, Mike! Quick question: didn't the unit come with rubber feet to decrease transferring vibrations and noise?
@Deckardrick007
@Deckardrick007 3 роки тому
It's so quite that it doesn't emit that much vibration. Mine doesn't.
@joshramsey6893
@joshramsey6893 3 роки тому
Bill, I’m one of the guys in the video and I own an air conditioning company. I can tell you for sure the outdoor unit is virtually silent so no additional vibration isolation is needed.
@Shadetreecruiser
@Shadetreecruiser 3 роки тому
I installed the DIY single unit a year ago and love it. It simply works perfect. The rubber feet are recommended when mounting the unit to the wall using a bracket to reduce vibration to the house. They are not needed when mounting to a standalone concrete pad. As others mentioned it is ridiculously quiet.
@joshramsey6893
@joshramsey6893 3 роки тому
@@Shadetreecruiser Steve that makes perfect sense to me. The pad doesn’t connect to the house so it can’t transfer vibration. If you did have a pad that was connected then I might add the rubber pads.
@nickjohnson5697
@nickjohnson5697 3 роки тому
The compressor is mounted with rubber grommets. There is no vibration.
@TheHarryChanne1
@TheHarryChanne1 3 роки тому
Maybe prime and paint that exterior white plastic conduit when you patch the stucco?
@WildmanTech
@WildmanTech 3 роки тому
Excellent! This will solve an issue for me!
@juaniec2
@juaniec2 2 роки тому
Great video, great info and clean install.
@RossLemon
@RossLemon 2 роки тому
Is this the dude that did the attic theater room build where he dry walled over a window?
@chaos.corner
@chaos.corner 2 роки тому
We have a window like that from a previous owner except it's a wood panel behind a cupboard.
@taylorsessions4143
@taylorsessions4143 3 роки тому
Bob: What are you doing in my house? Also Bob: Cool dog
@arjumanddawre4779
@arjumanddawre4779 3 роки тому
Omg you've reached 1.5 mil already??♡♡
@The52brandon
@The52brandon 2 роки тому
I hope this comment isn't misunderstood as criticism but if I can make a suggestion - put "install" right after "DIY" at the start of the title so it says "DIY install Multi-Zone Ductless Mini Split AC". I definitely don't believe you were trying to clickbait or mislead with the title, but I was definitely expecting a very different video. However, it actually worked out for me as I've not really looked into many ready-made ductless mini-split systems in my quest to convert a window-mount AC into a mini split. I've only really looked into videos of other people that did the same - which I now see was a mistake. There's a lot more optional features for mini-split systems than I had originally assumed... I guess that's why there's such common sayings regarding making assumptions... So, thank you for that. Take it easy...
@pablopicaro7649
@pablopicaro7649 2 роки тому
Do not spool refrigerant lines in a Vertical plane, the lubricating oil will eventually get trapped in bottom of Suction loop,. compressor will stave for lube oil. make loops in Horizontal plane so oil can keep flowing.
@Vandalfoe
@Vandalfoe Рік тому
I'm no HVAC engineer, but that oil has to travel an 8-foot stretch straight up the wall. How could it do that if it's not capable of going up and down some one-foot loops? Just wondering. Thanks.
@redmatrix
@redmatrix Рік тому
@@Vandalfoe I believe the oil mixes with the gas and has no problem when traveling up, but when coming down, it tends to "pool" on vertical loops and get trapped there slowly, over time
@jeffreyeaton8099
@jeffreyeaton8099 2 роки тому
Missed an important step on the video: when you open the valves to the line sets you must ALSO open the master valves located above all of the places where the zone line sets connect on the outdoor unit .. do this prior to turning on the unit. Otherwise a great video.
@SayanChakrabortycrixus90
@SayanChakrabortycrixus90 3 роки тому
Who saw all the new videos coming later from this channel in the whiteboard 😎😎😎 excited
@californiacritic9779
@californiacritic9779 3 роки тому
@Modern Builds, you should definitely do a stucco video. You can show how to DIY.
@TERRORoftheLORD
@TERRORoftheLORD 3 роки тому
The theory behind the mini split is slow constant airflow. So turning them on and off will actually make them less efficient. Running them slow and constant is the key to efficiency.
@zaktremewan5818
@zaktremewan5818 2 роки тому
That is correct, as I install them
@michaelkaylor4779
@michaelkaylor4779 3 роки тому
I’m interested in what the electric bill is going to be as well.
@joshcosta423
@joshcosta423 3 роки тому
TURNED OUT 🔥🔥🔥🔥🔥🔥🔥🔥
@joshcosta423
@joshcosta423 3 роки тому
I mean, ❄️❄️❄️❄️❄️❄️❄️
@ricecakeboii94
@ricecakeboii94 2 роки тому
Could use the hole for a window instead of a stucco patch? Depending on what it’s facing can let a lot of natural light in
@markmagner8000
@markmagner8000 3 роки тому
my dude im not hating .... but i dont think u need all that rebar ??? lol
@erikedwards2594
@erikedwards2594 3 роки тому
5:34 Square to the earth? Square. To. The. Earth? I’m sorry?
@karmaremusic
@karmaremusic 3 роки тому
LOL
@rachelkarmel2834
@rachelkarmel2834 3 роки тому
LOL
@RachelKarmelMusic
@RachelKarmelMusic 3 роки тому
bahahaha
@secretseptember2937
@secretseptember2937 3 роки тому
This is awesome and the funny part before I wacth commercial of mr. Cool
@muneshwarshewbaran2525
@muneshwarshewbaran2525 2 роки тому
Great job mr cool,i always wanted to installed a full wall unit in my home,but can't find the correct person or company.
@daffron101
@daffron101 2 роки тому
there is a tool that lets you make flare fittings so you can cut the copper to the perfect length so you dont leave it bunched up and create an oil trap that is bad for the unit. surprised the HVAC techs didnt have one....
@rogerfar
@rogerfar 2 роки тому
You're supposed to leave it coiled up..
@daffron101
@daffron101 2 роки тому
@@rogerfar it traps the oil. Over time it won't run right...
@MyGoogleYoutube
@MyGoogleYoutube Рік тому
The problem is that these are precharged linesets. They have special fittings.
@daffron101
@daffron101 Рік тому
@@MyGoogleUKposts exactly and the fittings would still be used but you'd still have to cut the excess copper. the flaring tool just flares the copper after you cut to the length you need and then you thread the flaring caps on the valves like normal.
@MyGoogleYoutube
@MyGoogleYoutube Рік тому
@@daffron101 Then it's not diy. That is the point of the lineset.
@JesseStarrPhoto
@JesseStarrPhoto 2 роки тому
It's hard for me to be sure without being there but I'm 95% positive you have a Zinsco electric panel and if so, it needs to be replaced if you want to avoid an electrical fire...
@lippru
@lippru 2 роки тому
It's a Sylvania/GTE Panel. Label on lower right corner. This model could be the earlier ones associated with Zinsco. Later models use Cutler Hammer breakers.
@JesseStarrPhoto
@JesseStarrPhoto 2 роки тому
@@lippru sylvania/gte labeled panels can be zinsco. The breakers have the distinctive zinsco colors
@JesseStarrPhoto
@JesseStarrPhoto 2 роки тому
@@lippru here’s some information for you. I’m a certified professional inspector. inspectapedia.com/electric/GTE_Sylvania_Zinsco_Identification.php
@lippru
@lippru 2 роки тому
@@JesseStarrPhoto Thanks for the link. I am a retired union electrician. I was involved in replacing these breakers and panels back in the '80's.
@matthewellis2334
@matthewellis2334 3 роки тому
I saw ur ad on UKposts it was cool i gave it a thumbs up . 😁
@annie-centrepiecefurniture
@annie-centrepiecefurniture 3 роки тому
Nice work Mr Cool 👏
@ssapinn
@ssapinn 2 роки тому
the electrical cables that feed the system were very very badly installed, you can see they cut cables to reduce the diameter so each cable can fit in one side of the holder, bad method! you can use an electrical terminal and use the full diameter of the cable and reduce the heat in the cable and consume less energy.
@robertberin4872
@robertberin4872 2 роки тому
Hmm. That's what I did. Considering this only uses 5amps how is it going to generate heat?
@hvacdoc
@hvacdoc 2 роки тому
Those loops in the line are going to act like traps and trap the oil in the system
@mumadafaka
@mumadafaka 3 роки тому
Great job! Liked a lot the condense outlet. What for is the white hanging cable in 8:33? Seems obsolete. Still visible after finishing touches.
@Ace2789able
@Ace2789able 3 роки тому
Very nice setup! Good instruction video
@21toolmantim
@21toolmantim Рік тому
It’s been a year since posting this video. Any word on the electricity bill? I’m considering getting a couple of these for a house remodel. Very little to no snow in my area but a lot of great comments of things to keep in mind, mainly have an HVAC guy handy and don’t leave extra line coiled up. But, I’m very interested in how this impacted the electric bill. I can’t find anyone that has one who shared the difference it makes on the electric bill, good or bad.
@allen35315
@allen35315 Рік тому
Just the info I'm looking for also.....
@MarcelHVAC
@MarcelHVAC Рік тому
This installation is already scrapped since it is garbage
@zivaschan
@zivaschan Рік тому
​@@MarcelHVACno it's not. why, is mr cool diy installation reducing your labor profits? lol you just have to make sure to follow the install manual and be up to code. it is doable for those already experienced with electrical as well as fixing things around the house.
@YB-eg3rj
@YB-eg3rj Рік тому
FYI, you can’t use pressures on these systems. They’re critically charged. It will give you an idea but keep in mind everything modulates according to the load.
@zivaschan
@zivaschan Рік тому
i was wondering why they were testing it when the lines are precharged but i had the video on background and was multitasking
@lechatbotte.
@lechatbotte. 3 роки тому
I was wondering where you’ve been hee hee. But I keep seeing you on adds here on UKposts. This is great if I needed AC this looks doable.
@ModernBuilds
@ModernBuilds 3 роки тому
I've got a lot filmed and I'm in edit mode currently! more on the way :)
@eladlevi47
@eladlevi47 3 роки тому
Very nice and clean work !
@mauriciogonzalez6302
@mauriciogonzalez6302 2 роки тому
Points the laser thermometer at the AC to determine how quick it’s cooling the room 🤔
@Extra-Salt
@Extra-Salt 2 роки тому
exactly what i was thinking. haha amazing how my hotplate increases my "room" temperature moments after lighting.
@mikemcdonald5147
@mikemcdonald5147 2 роки тому
if mrcool wants to send me one for free id be happy to do a video for them as well.
@Charlie220966
@Charlie220966 Рік тому
Hi, this looks great. Do you know, can this outdoor unit be placed higher than inside units??
@ShawnMeira
@ShawnMeira 3 роки тому
I just saw a home Depot ad with you in it xD
@fernandopenah
@fernandopenah 2 роки тому
Some of the electrical connections at the Condenser Unit looked like they could’ve been done better and I would’ve foamed the wall penetrations to avoid critters and better sealing but other than that these DIY A/C units look like a good option for a Garage. If it breaks in 3-5 years who cares.
@robinsonmechanical5439
@robinsonmechanical5439 3 роки тому
Didn't talk about sizing?? Can't just throw in a AC system with out sizing it correctly I get the precharged linesets but alot of manufacturers of "duct-less" have minimum requiments on line set length, coiling the line set like that in the back is incorrect an is NOT recommended by any manufacturer that I've seen, creates a oil trap. Also the box he built is not recommended beacuse most manufacturers have distances requirements for the outdoor coil (condenser) Also, no torque requirements on the lineset connections? No feet for the Outdoor coil? All heat pumps must be raised tobe drained to prevent ice daming in winter. Also, No surge protector on the disconnect? Would be nicer if it was on the other side of the outdoor coil but hey you have one. Do not install this yourself, call a HVAC pro, get 3 different bids and don't go with the lowest one. Plus most HVAC pros have warranties. But hey that's a sweat condesate drain...
@kellilandry2825
@kellilandry2825 3 роки тому
Looks great! I'm interested in the stucco process, may be you could do an IG story on it?
@MiteyMOofyearsAgo
@MiteyMOofyearsAgo Рік тому
Very nicely done. Thank you!!
@MaximaToluene
@MaximaToluene 3 роки тому
Anyone excited for his UKposts Roadmap teaser on his whiteboard? 😂
@Deckardrick007
@Deckardrick007 3 роки тому
These units still need to be vacuumed by a professional. You can use the precharged lines but it lessens the life.
@Deckardrick007
@Deckardrick007 2 роки тому
@Dyeffson Dorsaint that's what tried to do at first. Best have a professional do it. You really don't want to buy another unit two years later.
@Deckardrick007
@Deckardrick007 2 роки тому
@@Ampacityelectric haha that's exactly what the tech told me after he helped vacuum my lines. So far I've had mine for 2 years and I already had to charge it once.
@adamabelha4363
@adamabelha4363 2 роки тому
@@Deckardrick007 It is NOT TRUE that these units need to be recharged in a year or two. If you had to recharge it is because you had a leak .
@RadioRich100
@RadioRich100 2 роки тому
@Dyeffson Dorsaint if you coil the lines then you might as well not do the rest of the job right.
@kylewestendorf3068
@kylewestendorf3068 2 роки тому
No they don’t idk why everyone keeps saying that. Put one in and see for yourself like I did.
@ocalaeyeguy
@ocalaeyeguy 8 місяців тому
Can you keep the two rooms on different a/c settings……. One at 75 degrees and the other at 79 degrees?
@ricos4700
@ricos4700 Рік тому
Great video. You had two units. How many sq ft did this serve? Is the condenser unit outside very loud?Thanks for the information 👍
@jesussavesanus9790
@jesussavesanus9790 2 роки тому
Lmaoooo "this much water will never come out of this system so its fine" one humid day is all you need.
@answernotfound5278
@answernotfound5278 2 роки тому
It’s really not the best idea for your line sets to be coiled in the upright position… all of the oil will drain out of the compressor and get trapped.
@toolegit2quit173
@toolegit2quit173 2 роки тому
Hmm, that makes sense. So you’d recommend running your coils on the horizontal instead?
@henryterrell1956
@henryterrell1956 3 роки тому
Awesome! I see you using The Studbuddy! I work for them and probably shipped that studfinder to the Home Depot you bought it at!
@ModernBuilds
@ModernBuilds 3 роки тому
That's awesome!! the Studbuddy is so simple its perfect
@davidgranderson5435
@davidgranderson5435 2 роки тому
Great video. I wanted that AC unit in my apartment but I'm on the 3rd floor
DIY Mini Split Install - All the Things Nobody Shows You
33:25
LRN2DIY
Переглядів 1,7 млн
DIY MULTI-ZONE Ductless MINI SPLIT Installation in New Construction!
17:14
Crafted Workshop
Переглядів 576 тис.
Сакура із свічки
00:35
Afinka
Переглядів 153 тис.
Артем Пивоваров х Klavdia Petrivna - Барабан
03:16
Artem Pivovarov
Переглядів 8 млн
DIY Mini Split Install: Mr. Cool, Multi Zone System.
53:28
FarmCraft101
Переглядів 118 тис.
Installing a 3 ZONE Ductless HVAC System
16:52
Quality HVACR
Переглядів 106 тис.
Mr Cool DIY 2-Year REVIEW: I wish I would have known this BEFORE BUYING...
19:58
MRCOOL DIY Multi-Zone Mini Split | System Install | Ep 2
30:45
MR Post Frame | Marshall Remodel
Переглядів 17 тис.
Step-by-Step Guide: Installing DIY Mini Split Dual Zone | Senville | Mr Cool
37:40
I Like To Build Stuff
Переглядів 573 тис.
#1 Reason Why DUCTLESS Units Fail | How I Fix It...
13:59
Quality HVACR
Переглядів 726 тис.
Should You Install Your Own Mini Split?
16:45
Fix This Build That
Переглядів 99 тис.
How to Install a Whole-House Ductless System | Ask This Old House
6:40
Mini Split - 3 Things I Wish I Knew Before Installing
8:44
LRN2DIY
Переглядів 1,1 млн
MRCOOL DIY Multi-Zone Mini Split | Electrical + Testing + Initial Review | Ep 3
35:43
MR Post Frame | Marshall Remodel
Переглядів 12 тис.
Constipation - 3d animation  #meded #anatomy #3dmodel
0:21
SciePro
Переглядів 57 млн
ПОЧЕМУ ОБ ЭТО НИКТО НЕ ГОВОРИЛ?!😱🔥 #shorts
1:00
Лина Погорелова
Переглядів 12 млн