Earth Electrode Testing

  Переглядів 492,618

John Ward

John Ward

7 років тому

Overview of different methods of testing earth electrodes to ensure their impedance is low enough.
► Support this channel:
Patreon: / jwflame
PayPal Donations: xo4.uk/?PPP
► Social Media:
Twitter: / jwflame
Facebook: / jwflame
Instagram: / jwflame
► Contact info, sending stuff in: etc.:
xo4.uk/?YTT
► Website - More on this video and many other subjects
Website: www.flameport.com
Page for this video: xo4.uk/?Qng

КОМЕНТАРІ: 144
@ebaystars
@ebaystars 3 роки тому
I am building my home in Thailand, realising early on that there is no electrical standard and very little knowledge of Earthing, I decided to use an UFER grounding system. All my rebar is connected together, by welding and thick copper/brass cable joints, then concrete is poured and metal points at 4 corners of each building come out and all the risers and are connected above the floor plane to a common point by copper cables, all dry, sheltered and protected. For anti corrosion I smuggled in a tin of Copperease (can't get that here along with Marmite and PG Tips) as we used to use that on ships' antennae installations, it doesn't wash off or emollify much. I use a Three Terminal Ying Tong Meter as above and thank you for your video as when I got it the bloody thing the destructions were all in Chinese. For the whole installation therefore I use multiple earths for each supply box being the UFER grounds, as the company supply earth isn't available (LN only) and anyway it's just a piece of galvanised metal buried in dry sand. Drinks are on me if you are ever in Hua Hin area.
@andreim841
@andreim841 7 років тому
Thank you for taking the time to make all these great videos and educate the rest of us. Best of luck to you and your family in 2017!!!
@56jmack
@56jmack 7 років тому
Another excellent, well explained video.Cheers John.And Happy New Year
@robbiesinyangwe5662
@robbiesinyangwe5662 4 роки тому
Thank you for your time to teach. You make understanding simple. Thank you Sir!
@i-will-get-you-there
@i-will-get-you-there 7 років тому
Thanks for the vid... Have a good new year! Cheers
@MD0MDI
@MD0MDI 5 років тому
Very useful, thanks very much for also adding the what if section, really helpful.
@jeffclement9448
@jeffclement9448 5 років тому
Thank you for your video. Very informative and helpful.
@davidnorthcott9229
@davidnorthcott9229 5 років тому
Fantastic video. Thanks for making it look easy to understand
@firasalam1
@firasalam1 Рік тому
Thanks A lot John! very clear and the explanation is straight to the point !
@jsanti725_Offl
@jsanti725_Offl 6 років тому
thanks a lot for your recommendation and knowledge
@crigeorge9549
@crigeorge9549 6 років тому
good explanation John.
@tgwallbank
@tgwallbank 7 років тому
Just to say I really enjoy your videos, the style in which they are presented and that I appreciate the amount of time you must spend in doing these. Thank you.
@bobhatcher5505
@bobhatcher5505 7 років тому
Very informative, thanks!
@arqamsaeed1228
@arqamsaeed1228 4 роки тому
You done a great job thank you so much. Very useful for me.
@TinG-hz7fm
@TinG-hz7fm 3 роки тому
Great video, though you could have mentioned that the middle electrode (commonly designated as S) is just a high impedance voltage measuring probe, while the outer probes (commonly designated as E (earth) and H(auxiliary)) are used to inject AC current into the soil. Resistance is calculated internally as the voltage measured at the S-probe divided by the current measured internally by the instrument itself.
@fardellp
@fardellp 7 років тому
Surely the resistance will vary greatly at the same installation depending on the type of soil and for a given soil type, its wetness or dryness. Presumably the test should be done after a (long) dry spell.
@wayneisinwater
@wayneisinwater 7 років тому
hey john! great video. i realyl like the quality of your videos. what kind of camera do you use?
@henryvergara3303
@henryvergara3303 4 роки тому
Thank you for this video sir.it's my first time working in earthing and im looking for some info.and im found yours.thanks.
@MDMAx
@MDMAx 6 років тому
Thank you so much!
@peachy-karen
@peachy-karen 3 роки тому
Cheers for additional knowledge..
@Chimp_No_1
@Chimp_No_1 6 років тому
Wonderful.. So helpful, thanks John
@CaptainK007
@CaptainK007 5 років тому
(Newbie) So what’s the score on wet ground? If you do the tests/install in a soggy February and you get good reading and we have a very dry summer and the ground drys out. Cheers enjoy the vids.
@alialshammari4985
@alialshammari4985 2 роки тому
Thank you so much sir for your rich information and simple gorgeous way in explaining the lecture, appreciate your help and effort making the information so simple and approachable, from kuwait ali
@Michelle-jc7dj
@Michelle-jc7dj 3 роки тому
Really informative videos. Be great to have one on hot tub installations as there's a lot of conflicting information around interpretation of BS7671 special locations, PME, TT systems etc. I'm sure you could guide people through the correct best practice, and I for one would appreciate some expert clarification.
@christiandogbe8546
@christiandogbe8546 Рік тому
This is deeper knowledge. We greatful
@ajvantonder7055
@ajvantonder7055 2 роки тому
Hey John hope you can help me with the question it reads: A maximum earth resistance of 300 Ω, shall be maintained between electric fence earth electrodes. Do I connect the leads to both electrodes +- 30meters away. Or do I insert the small electrodes into the ground as shown on your video the electrodes are 1.2meter long.
@amroshareef100
@amroshareef100 5 років тому
Dear Sir I'm working on an existing hospital over 30 yrs old, and i found only lightening pits connected to the lightening grid on roof, how should I test the earthing system and is it possible for the designer to used the concrete grid instead of the earthing electrode ?
@ajithkumaraha
@ajithkumaraha 3 роки тому
Great video very helpful
@JEFF-Elliott
@JEFF-Elliott 2 роки тому
Hi this is great because it gives me ideas of how to achieve my goal, but I would like to know more about the meter you’re using I have been told I need to use a mega but this looks like something else you have but you did not mention what it was. I use Radio and I need to know I have a resistance of less than 10 ohms. This sends current, and I am afraid to test as I may damage my equipment. 🤔. This demonstration 👍 just need to know more.
@jenko701
@jenko701 7 років тому
I like your videos because I like to see the differences from here in the US . We should all use the term earthing like you guys do . We just say grounding wire and some times there is confusion between it and the neutral , and as you know we split our 240 to 120 circuts so a neutral go with every 120 circut. This was deliberately set up by Elihu Thomson for safety?
@nilusahio3786
@nilusahio3786 7 років тому
why resistance decreases by increasing the distance between the two rod?
@user_i.d
@user_i.d 4 роки тому
If u use a earth grid or earth tape how far do they need to be in the earth?
@Appregator
@Appregator 2 роки тому
Do you have a reference for the easy method on your videos? I can't find the link despite searching. Thanks.
@Animation_jokes
@Animation_jokes 6 років тому
Need more details regarding how exactly this mechanism works
@sshrek1996
@sshrek1996 2 роки тому
How to measure the resistance of the grid ? I believe the grid resistance will affect the earth resistance. Please correct me if I'm wrong
@gntviix582
@gntviix582 3 роки тому
For real , thank you sir
@Motorman2112
@Motorman2112 7 років тому
Thanks John. You mentioned that you might be doing these tests while it is raining. Is it necessary to repeat the test when the ground is drier to ensure that the resistance will still be low enough during hot periods with little rain, or does it not change much?
@rrrrrrrrrrrrrrrrrr0
@rrrrrrrrrrrrrrrrrr0 Місяць тому
Ideally you want to do it when the conditions are least favourable, say a hot dry day
@ninav74
@ninav74 4 роки тому
What's the purpose of moving the earth spikes please?
@rajnishsaharawat3256
@rajnishsaharawat3256 3 роки тому
thanks a lot sir
@Teenagegoogoomuk
@Teenagegoogoomuk 7 років тому
Damn!! here in the US we have to use 10 foot (3m) rods and achieve 3 to 6 ohms of resistance. I've also had to use 1/4" x 12" X 12" copper plate or ufer grounds for the hard to get places.
@energiavadasz3328
@energiavadasz3328 5 років тому
Because of the 110V mains
@dreamkiss
@dreamkiss Рік тому
I am trying to find the video for the first method of earth testing when power is available, cannot find it ?
@valyardelean
@valyardelean 4 роки тому
What do you do when you have the earth rod to test surrounded by concrete slab, where do you put the test probes with the spikes? Thanks for the vid 🤗
@jwflame
@jwflame 4 роки тому
If it's all concrete then you can't- however other test methods are available.
@valyardelean
@valyardelean 4 роки тому
@@jwflame I was thinking to try a Ze test.
@mongaabraham674
@mongaabraham674 2 роки тому
Nice course i appretiate it good explaination but thats not enough for me you suppose to talk about the soil type as well and the great ground résistance value for in low voltage and Médium voltage
@danieleuboldi996
@danieleuboldi996 6 років тому
Hi John, do you any video showing the use of method 1, i.e. mains?
@jwflame
@jwflame 6 років тому
Not yet. Hopefully will do videos showing all of the various tests, but it is rather difficult to find somewhere that it's possible to show the tests, and get permission of the building owner. Making a video while doing them means it will take several times longer, so a few hours of tests could end up taking a couple of days - most people don't want that.
@mwemamutua191
@mwemamutua191 4 роки тому
Hi John do you have video showing testing when mains available ? Or can u explain in writing ?
@sbusweb
@sbusweb 7 років тому
When doing the 'rod test', all very well testing your own electrode, but what about the impedance of the earth-electrode at the source transformer, how do you test that // what standards is 'their' elecrode rated/checked to?
@jwflame
@jwflame 7 років тому
It should be less than 21 ohms, usually a lot less. The earth electrode at the transformer is usually a large metal grid buried in the ground, not a single rod.
@ianlouden7939
@ianlouden7939 4 роки тому
DNO's sometimes spend more money getting a low enough earth impedance at the substation than the cost of the substation, TN-C-S is therefore more or less guaranteed to be good!
@AngDavies
@AngDavies 3 роки тому
Test again with mains, and compare the two?, Line conductor impedance should add rather little to the loop
@jenko701
@jenko701 7 років тому
I like your videos and for any one that likes the history of this topic a great person to look up is Elihu Thomson.
@user-vd6wb5ef8v
@user-vd6wb5ef8v 5 місяців тому
I could not find your video about measuring earth resistance when the main electricity is available, and ask my question here Can one get results using any household electric appliance like, say, Incandescent light bulb, a mulimeter and the old good Ohm's Law? One terminal of the bulb is connected to live, the other to earth and the current is measured. Divide voltage by current and subtruct the bulb's resistance and the result is the earth resistance.
@jwflame
@jwflame 5 місяців тому
In theory that could work. In reality you do NOT want to be attempting that, as doing so will put a significant voltage onto the electrode and anything else connected to it which could be dangerous. Would also need a circuit with no RCD on it, otherwise it would trip immediately. Other videos are here: ukposts.info/have/v-deo/l3Kcgm6diYKKuas.html ukposts.info/have/v-deo/g2CBaa1-iqCprXk.html all others can be searched from the main channel page.
@user-vd6wb5ef8v
@user-vd6wb5ef8v 5 місяців тому
@@jwflame Thank you for answering. If I got you correctly, this method will give sufficiently valid result, yet it is not safe. I still cannot understand the danger. Significant voltage is the same 240 (in my place it is 220) - and this is a voltage we handle habitually with common sense. I am going to use an electric plug and a lamp socket. Connect the live pole of the plug to one lamp socket terminal (the other plug pole unused). The other lamp pole terminal connect to the earth. Of course making all these connections while the main switch is off. RCD is already there
@bhupendrosalam6037
@bhupendrosalam6037 5 років тому
Some people ,knowingly or unknowingly, put common salt ,charcoal inside the pit(dug for the purpose), before putting a GI pipe (though costly). Will the salt help significantly or is it only a precaution?
@jwflame
@jwflame 5 років тому
It will reduce the impedance, but it will also increase corrosion so is not recommended.
@adelachacha2582
@adelachacha2582 3 місяці тому
so if we have well of earth 40m and electrode of 3m distance of t1 400 m
@jamesgrimwood1285
@jamesgrimwood1285 7 років тому
9:00 - Words spoken by someone who's obviously done this themselves ;-)
@tablatronix
@tablatronix Рік тому
So how do you do this without special testers? Seems like you could
@linossinkala7840
@linossinkala7840 Рік тому
Thankyou sir
@yousefghareeb8287
@yousefghareeb8287 7 років тому
Dear Mr.John , I have to test the earthing for 40 connected electrodes (earthing network ) . Please tell me if I can use 62 % way , and please tell me if i have to isolate the electrode from the earhting network during this test ? Best Regards,
@jwflame
@jwflame 7 років тому
You can test the electrodes together, but they must be disconnected from the electrical installation when testing.
@craigspacie7048
@craigspacie7048 7 років тому
John Ward
@gavinstirling9472
@gavinstirling9472 3 роки тому
How can you test an earth electrode if you can not find it because it's Hiden under a deck or something please ?
@gratitudeacademy8966
@gratitudeacademy8966 6 років тому
Correct me if possible, but i thought the ideal Earth test resistance should be less than 1 Ohm?
@jwflame
@jwflame 6 років тому
Less than 1 ohm on TN systems where the earth is provided from a cable. With an earth electrode (TT), resistance will be much higher as it depends on the resistance of the electrode to the surrounding soil, which is typically many 10s of ohms.
@MrDumbdane
@MrDumbdane 7 років тому
Here in denmark, we rely on rcd's for protection. They are in fact required by law to be installed in all consumer units. Therefore, the earth electrode needs to fit the rcd. As 50 volts is max alowed for humans to touch and most rcd's trip at 0,03 amps, the max resistans for the earthrod is 50/0,03 = 1666 ohms. Some equipment require 0,1 or 0,3 amp rcd's so 500 and 166 ohms. Could you please explain why you say 100 ohms for TT in england? And thank you for all the videos you do, I realy enjoy watching them. As others has said before, you can explain things so everyone can understand them. Keep them comming 🙂
@Jamal_Tyrone
@Jamal_Tyrone 6 років тому
According to the On-Site Guide (BS 7671) it's between 21 and 200 ohms on a TT Earthing System. Obviously the closer you get to 21 ohms the better.
@bobuk5722
@bobuk5722 5 років тому
Calculation is misguided. There's a potential divider effect. Faulty low rsistance load connected to high resistance earth rod gives a high voltage on the supposed 'earth' wire.
@humaali7881
@humaali7881 5 років тому
V nice sir good explain
@user-bu7kq7tz4d
@user-bu7kq7tz4d 5 років тому
where can I find the previous video or how is its filename so that I can watch it ?
@jwflame
@jwflame 5 років тому
All videos here, arranged by topic: ukposts.infoplaylists?shelf_id=0&view=1&sort=dd
@DerekkMurray
@DerekkMurray 7 років тому
I used to do this with a variation of a whetstone bridge
@ibrahimwahb2607
@ibrahimwahb2607 6 років тому
How we could test it if the main power available ?
@ooltimu
@ooltimu 4 роки тому
Wet your fingers and touch the mains cables
@sbkentertainmentknowledge4213
@sbkentertainmentknowledge4213 5 років тому
Well, Can you Clarify my few doubts Sir. 1. What is the reason behind puting the 10 time of Depth of Earth road. If not maintained what will happen
@valyardelean
@valyardelean 5 років тому
Than it's in the same area ...
@akinolaoluwabusuyiezekiel3306
@akinolaoluwabusuyiezekiel3306 3 роки тому
Thsnks
@Bharatmatakijai1112.....
@Bharatmatakijai1112..... 5 років тому
What is the angle between other two electrodes
@gntviix582
@gntviix582 3 роки тому
I think it has to be in the same line
@ekawakakonahi1174
@ekawakakonahi1174 5 років тому
What do you do for earthing the elctrode if you live on a old lava field and have no soil besides solid lava rock?
@Ricky-zj6sy
@Ricky-zj6sy 2 роки тому
I find it always best to use a 17th or 18th edition multi function tester to measure the Ra or earth fault loop impedance for the means of earthing. The three spike testers will not measure the critical loop to ensure automatic operation of the RCD's. They can be misunderstood and also show incorrect readings from the short temporary spikes into dryer topsoil rather than deep clay, Two wire testers will measure the entire earth fault path from the transformer through the line conductor, down the spike to the ground, and across the ground and back to the high voltage earth at the TX. this needs to be below 200 ohms and is the best method by far. You also need to ensure that you disconnect the earthing conductor and test only the means of earthing (NOT parallel paths to heating systems and water mains etc.) You MUST also ensure that this test is done with ALL current using equipment turned off at the main switch to ensure nobody can become injured while the earth has been disconnected.
@Ricky-zj6sy
@Ricky-zj6sy Рік тому
@David Morris Exactly David, that three wire test method is a nonsense and only tests the ground between the three electrodes used and not the critical Ze (Ra) measurement. Don’t waste your time attempting it mate.
@asadbaig9276
@asadbaig9276 2 роки тому
That sun looking cool
@electrisienali4584
@electrisienali4584 7 років тому
كيفيت حساب
@TanveerKhan-bk7sq
@TanveerKhan-bk7sq 3 роки тому
What shall be the earth electrode resistance
@jwflame
@jwflame 3 роки тому
Depends on the circumstances and the installation, but generally less than 200 ohms is required, and lower is better.
@ianlouden7939
@ianlouden7939 4 роки тому
It should be noted TT earth impedance can easily double from wet months to dry months throughout the year, I guess that why
@ragubathi1861
@ragubathi1861 4 роки тому
Super
@benharris2217
@benharris2217 7 років тому
is there not a risk of striking a buried cable or pipe when driving these electrodes in?
@jwflame
@jwflame 7 років тому
Yes, so a proper survey is essential before installing one.
@geoffmatthias3992
@geoffmatthias3992 5 років тому
Ben Harris Oh yes there is a friend of mine who is a spark was driving a spike in and hit a Gas pipe ? Gas company had to dig up a drive needless to say the owner was none to happy?
@josephsagoe5519
@josephsagoe5519 6 років тому
Good
@MrOckhamsRazor
@MrOckhamsRazor 5 років тому
He's wearing a Stewie T-Shirt. This is commendable !
@soewin9784
@soewin9784 Рік тому
Good.
@edmundfisher4951
@edmundfisher4951 7 років тому
Somebody is awake early!
@amerriaz10
@amerriaz10 7 років тому
so you do not want anyone else to learn
@pedrosegoviavarela3847
@pedrosegoviavarela3847 2 місяці тому
Quiero que se explique en español por favor..
@Pentti_Hilkuri
@Pentti_Hilkuri 7 років тому
What madman dislikes earth electrode testing???
@MartiA1973
@MartiA1973 5 років тому
Pass the hi Vis vest and boots. We playing in the mud! Another classic JW crystal clear explanation
@ebaystars
@ebaystars 3 роки тому
All Thai "electricians" who are also "car mechanics", "builders" "architects" "pilots" etc etc
@ryanelliott1650
@ryanelliott1650 2 роки тому
The type that wants to be an earth electrode
@propertyomgtv254
@propertyomgtv254 6 років тому
Dear sir, is the type of material of the electrode important and affecting the readings significantly?
@jwflame
@jwflame 6 років тому
No, as long as it is conductive. The main thing affecting resistance/impedance is the contact between the electrode and the surrounding soil. Longer rods or larger diameter rods will improve this as there is more surface area.
@propertyomgtv254
@propertyomgtv254 6 років тому
John Ward Dear Sir, many thanks for your kind reply. I was considering the options of electrode, as the high copper content composition one costs 4x more than the generic ones. Thank you. And i love your channel!
@mdrashidarafat8019
@mdrashidarafat8019 5 років тому
After getting resistance of electrode , how to get soil resistivity
@ibrahimabdullah4430
@ibrahimabdullah4430 6 років тому
Stewie Griffin 😂 1st thing I noticed when video started. Thanks for sharing another great video. 👍
@michaelagnew7825
@michaelagnew7825 3 роки тому
good vid, but slightly confused, putting aside the 10:1 rule surely connecting multiple rods to a soil with poor conductivity even if they are inches apart will gain more surface area, hence better figures. Im guessing that surface area plays a big role here
@jwflame
@jwflame 3 роки тому
Surface area is the main factor, so more is certainly better. Multiple rods close together will be better than a single rod, but spacing them apart is better still - and as the effort of installation is the same regardless of where they are located, they may as well be spaced apart.
@michaelagnew7825
@michaelagnew7825 3 роки тому
@@jwflame thanks JW, its an awkward question I know!
@michaelagnew7825
@michaelagnew7825 3 роки тому
@@jwflame I guess that if theres no option due to area restriction and crappy soil condition, planting them very close and bonding together is the second best thing as we dont want voltage potential
@fireblazer6661
@fireblazer6661 6 років тому
Question: Can a person who has ZERO ground in a house, ground just ONE power outlet in the house by running a ground wire from the ground terminal out into a grounded stake in the ground? My house has old screw in fuses, and absolutely no ground wire anywhere. There's no plumbing or anything in the house to use for a ground either. I run a compost toilet/outhouse, and haul water there. I want to avoid the risk of frying my electronics but I cannot afford a full electrical update. It's 10,000-12,000 to do this (almost as much as I PAID for the house!!)... I won't be able to afford it for YEARS best case. SO what I want to do, is somehow protect my electronics by at least grounding ONE outlet cheaply. Is this possible? AND NO, I DO NOT HAVE INSURANCE, so I don't care if things are certified insurable, just so long as my gear is safe.
@jamblob3208
@jamblob3208 3 роки тому
I am unclear why the electrodes need to be far apart yet tape or a grid or a pipe are considered the same thing. They are not only Not Far Apart but continuous?
@AngDavies
@AngDavies 3 роки тому
Given two electrodes, spacing them apart gives more 'bang for the buck' than putting them close together, tape/grid would just overwhelm that with shear area. I.e. where two electrodes far apart might have half the resistance, close together would have more than half
@williammacrae6119
@williammacrae6119 4 роки тому
Wrong middle lead is 62% of long leads distance
@MD0MDI
@MD0MDI 5 років тому
Is this what is called 'Ra' testing?
@jwflame
@jwflame 5 років тому
Yes, Rₐ is the resistance of the earth electrode and the conductor connected to it.
@MD0MDI
@MD0MDI 5 років тому
John Ward thanks John, having a nightmare trying to get a suitable Earth, presently cannot get below 1.8k with three earth rods, now going to try tape on Monday once Yesss opens up..
@jenko701
@jenko701 7 років тому
Did I hear you right , earthing electrodes are not required on new installations .
@jwflame
@jwflame 7 років тому
Yes, but only because new installations are very unlikely to be TT. If a new install is TT, then an electrode is required.
@computeraddic675
@computeraddic675 7 років тому
What is TT?But in the Netherlands,every dwelling,every family home,every housing flat has to have its own earth pin!If the Housing flat is long even more than one!It amazes me to hear this is not required in the UK for new installations.
@benharris2217
@benharris2217 7 років тому
Computer Addic We usually use the suppliers earth. the most common earthing method in the UK is known as TN-CS. essentially all line to earth fault are converted into line neutral faults. The earth electrode (or earth pin as you call it) is generally only used in rural areas.
@computeraddic675
@computeraddic675 7 років тому
So the resistance to earth is higher than in the Netherlands.We think 10 ohms is a lot!
@jwflame
@jwflame 7 років тому
TT is where the only earth connection is via the electrode, the electricity supplier does not provide any earth connection from their cable. Most supplies in the UK have the earth connection provided as part of the supplier's cable and a separate electrode is not required.
@rossaindow4390
@rossaindow4390 6 років тому
Why do we do this test ?
@jwflame
@jwflame 6 років тому
To ensure the impedance is low enough to trip the protective device (an RCD usually) when a fault occurs. If it was too high, a fault between line and earth in the installation would result in exposed metalwork becoming live, and the power would not be disconnected.
@rossaindow4390
@rossaindow4390 6 років тому
Thanks a lot great explanation
@rokutime2627
@rokutime2627 Рік тому
229 dislikes. Arrest former CEO Susan for protecting corporations.
@habiblee2603
@habiblee2603 11 місяців тому
I have concrete ground 😢
@toma9748
@toma9748 6 років тому
Stewie!
@Zilvinas021
@Zilvinas021 3 роки тому
Save the environment by writing on both sides of the paper or use a tablet!
@pedrosegoviavarela3847
@pedrosegoviavarela3847 2 місяці тому
I like and Englihs and spanish type bilingue okey...!
@singh-ov2qi
@singh-ov2qi 5 років тому
in hindi
@AshokKumar-ij8rc
@AshokKumar-ij8rc 6 років тому
ka hindi ma na bol sakte hai Na ki
@hiei3516
@hiei3516 4 роки тому
bare mumble
@natepeterson34
@natepeterson34 5 років тому
Horrid explanation JW! This is the worst training on earth electrode testing that I’ve possibly ever seen! If you don’t know what you’re talking about, why would you sit there and muddle your way through it and tell people some stupid stories!
Loop Impedance Testing
15:04
John Ward
Переглядів 282 тис.
НЕОБЫЧНЫЙ ЛЕДЕНЕЦ
00:49
Sveta Sollar
Переглядів 6 млн
Electrical Earth Rod Installation - New TT Supply
30:36
Mike Page
Переглядів 38 тис.
Ground Resistance Measurement, NEC 2014 - [250.53(A)(2)], (26min:27sec)
26:27
Where Does Grounded Electricity Actually Go?
19:36
Practical Engineering
Переглядів 4,8 млн
Lecture 11: Earth Resistance Test - Part 1
26:39
Railway Engineering Insights
Переглядів 7 тис.
Earth Electrodes - 3 Wire Testing Example (Part 3)
19:10
John Ward
Переглядів 39 тис.
Earth loop impedance test, ZE test
4:56
Universal Skills
Переглядів 58 тис.
Impedance Explained.
22:35
PKAE Electronics
Переглядів 10 тис.
Earth Electrodes Part 1
11:48
John Ward
Переглядів 98 тис.
Small Signal Amplifiers
57:53
Vocademy - Electronics Technology
Переглядів 263 тис.
Samsung UE40D5520RU перезагружается, замена nand памяти
0:46
Слава 100пудово!
Переглядів 3,8 млн
wyłącznik
0:50
Panele Fotowoltaiczne
Переглядів 2,6 млн
Радиоприемник из фольги, стаканчика и светодиода с батарейкой?
1:00
#Shorts Good idea for testing to show.
0:17
RAIN Gadgets
Переглядів 3,2 млн