How To Install A 240V Outlet In Garage - EV Car Charger, Welder, And Electric Range (Hubbell 14 50)

  Переглядів 501,399

The Excellent Laborer

The Excellent Laborer

День тому

In this video, I show you how to install a 240 volt outlet in a garage. This 240 volt outlet is also known as the 220 volt outlet for charging an EV car charger, welder, or even an electric range oven. A EV charger requires a 14 50 for a 50 amp outlet. I compare the Hubble 14-50 vs the Leviton 14 50 outlet. #electrical #tesla #diy
My Favorite Tools And Supplies 👉 www.amazon.com/shop/theexcell...
Tools And Supplies Used In This Video👇
Hubbell 14-50 Outlet amzn.to/3QLoNbS
Hubbell Outlet Cover amzn.to/3QJvqLw
Surface Mount 14-50R Receptacle amzn.to/3u5J1nS
6/3 Romex Wire amzn.to/46TotNI
50 AMP Homeline Breaker amzn.to/3SKgkqT
2 Gang Metal Box amzn.to/3SulaIE
3/4” Romex Connectors amzn.to/3FLaMo9
Mud-Ring 2 Device amzn.to/46YBi9o
Tesla 14-50 Adapter amzn.to/3FMZf7G
ChargePoint Charger amzn.to/3MvF6qv
More Helpful Related Videos👇
ALL Electrical Playlist • Electrical
Dryer Receptacle Installation - 4 Prong Outlet Wiring • Dryer Receptacle Insta...
How To Wire A Sub Panel - VERY DETAILED INSTALLATION! Start To Finish • How To Wire A Sub Pane...
🟢 Become a channel member:
/ @theexcellentlaborer
🔴 Subscribe to this DIY channel: ukposts.info...
🟡 Check out my Amazon store: www.amazon.com/shop/theexcell... . Here you will find tools and supplies used in my videos. (DISCLAIMER- I am an Amazon affiliate. I get a small commission that helps support the channel at no extra cost to you)
Timestamps
Intro 00:00
NEMA Outlets Explained 00:28
240 Volt Supplies 04:14
6/3 Wire Rough In 06:53
Metal Electrical Box Installation 08:13
NEMA 14-50 Outlet Options 11:10
240V Outlet Installation 14:45
Connecting 6/3 Wire To Panel 21:04
50 AMP Breaker Installation 24:37
240V EV Car Charging 27:38
Disclaimer: This video is all based on my personal opinion and is for entertainment purposes ONLY. I am not a financial advisor, CPA, attorney, tax advisor, electrician, plumber, housing contractor, designer, or any type of profession to give advice. I am just a consumer sharing my experiences and research. If you do need knowledge for those types of things, I will advise you to seek help for those professionals.

КОМЕНТАРІ: 371
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Hey! I covered A LOT of information in this video, so I placed timestamps below to help you navigate this video. Also, you can join the channel using this link ukposts.info/the/UJXaEduMHGB3Iap3DusmAA.htmljoin . We would love to have you as member! NEMA Outlets Explained 00:28 240 Volt Supplies 04:14 6/3 Wire Rough In 06:53 Metal Electrical Box Installation 08:13 NEMA 14-50 Outlet Options 11:10 240V Outlet Installation 14:45 Connecting 6/3 Wire To Panel 21:04 50 AMP Breaker Installation 24:37 240V EV Car Charging 27:38
@joeboxter3635
@joeboxter3635 6 місяців тому
Which one is needed for split air heat pump that says it needs 220V? Eg LG?
@scottburchfield8272
@scottburchfield8272 4 місяці тому
Can I use a 2/0 2/0 2/0 wire to run a range or stove
@solarkbike8
@solarkbike8 3 місяці тому
Where is the Ground Fault protection ?
@user-uf9mi6yi5b
@user-uf9mi6yi5b 5 місяців тому
I just want to caution everyone that using NM cable for this circuit limits you to the 60 degree column for Ampacity (NEC 334.80), that's 55A here. Furthermore, maximum current based on a continuous load should be no more than 40A's on this circuit since 125% x 40 = 50A. Therefore, never plug a 48A smart charger into this receptacle as some homeowners down the road may do and perhaps label the receptacle to say 40A MAX if you are going to use these 32A mobile charging cords. Note: even if you use 6AWG THHN rated at 90 degrees, your receptacle can only be used for less than 50 Amps. For me personally, I don't even install receptacles anymore for EV's, as they were just never designed for these high and continuous loads over periods of 8 hours or more. Also consider the constant unplugging and plugging in at the receptacle; your terminals will be lose in no time with a chance for arcing and a fire very high. Buy a hardwired smart charger instead and have it installed by a licensed and insured professional!
@curtisbme
@curtisbme 3 місяці тому
"Also consider the constant unplugging and plugging in at the receptacle" Good guidance however this part wouldn't happen as the charger would get plugged into the outlet and left there. No different than a dryer or other appliance.
@JM-iz3fr
@JM-iz3fr Місяць тому
The ev chargers are 240 volt, no neutral necessary. They also are required to be gfci protected
@StashySleepy
@StashySleepy 4 дні тому
The yinzer accent is pristine. Feels like home. 😉 Excellent video, man.
@darwood6861
@darwood6861 Місяць тому
Great video. One of the best I've seen. Just call it 240v. In 38 years I've never measured 110v or 220v. All voltage is nominal from the power company, but they have been supplying higher voltages for my entire life
@brianerock
@brianerock Місяць тому
A VERY CLEAR demonstration video! Good job! The only omission, however, is that the 2-pole breaker MUST be a GFCI-type breaker per NEC® 210.8(A)(2) and 625.22. Any personnel protection against ground faults internal to the EVSE protects SOLELY the EVSE OUTPUT CORD to the EV but NOT the EVSE INPUT CORD from the NEMA 14-50R receptacle to the EVSE. (Technically that GFCI-type breaker would eliminate the need for refund GFCI protection integral to the EVSE UNLESS the EVSE performs power conversion [nearly all DO NOT convert]). - Brian Rock, Hubbell Incorporated, I also serve as a CMP-2 and a CMP-15 Member but this is strictly my own position (not NEMA’s and not NFPA’s) I also am one of the 7 co-authors of the original (1996) NEC® Article 625 for Electrical Power Research Institute (EPRI).
@adamlloy2807
@adamlloy2807 5 днів тому
Brian, I'm in the middle of wiring my detached garage right now, and am having some trouble figuring this one out. It seems that the manufacturer specifies NOT to use a GFCI outlet for an EVSE 40 amp charger (50 amp breaker), and that the EVSE has GFCI built in. That said, I note your comment above regarding input/output. My issue here is that these chargers are known to trip a GFCI outlet or breaker, much like a tredmill does. What is the work around here in order to have a reliable appliance and meet code? My charger is corded - specifically a JuiceBox Pro 40 model and I id wire it into a external waterproof housing containing the NEMA 14-50. For that matter - any recommendation for wiring in a treadmill in a detached garage as well? I plan to dedicate an outlet for this and wiring it straight to the panel on a non-GFCI/AFCI breaker. Any suggestions?
@josephleyva7471
@josephleyva7471 3 місяці тому
I really appreciate how thorough you describe each step. Your a great instructor. Just what I needed. Shalom
@joepacheco7979
@joepacheco7979 3 місяці тому
I think this was the clearest, well explained video I've ever seen on UKposts. Keep it up. Thanks!
@pauljanssen7594
@pauljanssen7594 5 місяців тому
On that ground wire I usually bend it in a u-shaped so there's more surface, and that 75 inch pounds. Which calculates into 6 foot pounds.
@joshuabowen316
@joshuabowen316 6 місяців тому
Dude you just saved/made me thousands of dollars you are the MAN.
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Awesome! I’m glad I can help. Good luck with the rest of your projects!
@johndernberger1961
@johndernberger1961 6 місяців тому
Nice job. In reference to the outlet placement for stoves, I recommend reviewing the stove install instructions. There is normally a diagram for the placement for the outlet. I really enjoy your channel.
@Tom-mu7zy
@Tom-mu7zy 2 місяці тому
Good for you for grounding the outlet box. Too many UKposts experts fail to do that.
@TheExcellentLaborer
@TheExcellentLaborer 2 місяці тому
I always ground my metal boxes. Thanks!
@edgecomber
@edgecomber Місяць тому
Yes, but he ran the wirec ounterclockwise around the screw. Much more likely to work loose.
@royquiroz3359
@royquiroz3359 4 місяці тому
Excellent step by step explanations and instructions. Thank you!
@vbarbee1
@vbarbee1 5 місяців тому
I'm by no means an electrician, but have Don electrical work and taught by some great electricians. I was always taught when tightening wires against a box to route the wire in the same direction the wire tightens. That way the screw doesn't push the wire out, it draws it in. Use wire strippers not knives especially razor blades. When tightening lugs, tighten, back of, tighten, back off then torque. Also anytime adding new wire to a panel to kill main power. The person who taught me had a saying. The day you get complacent is the day you will get hurt or killed.
@darrendolphdragos9752
@darrendolphdragos9752 4 місяці тому
" I was always taught when tightening wires against a box to route the wire in the same direction the wire tightens" - When the wire is completely looped IE: out of cable, around screw, then into receptacle... it doesn't matter. Looping clockwise only matters on an open ended (cut) "hook" loop of wire.
@mikemm60
@mikemm60 2 місяці тому
or get the proper PPE, tho turning off breaker is cheaper.
@dustenskinner8404
@dustenskinner8404 Місяць тому
You make great videos man, highly informative and easy to understand. Greatly appreciate you doing the work and teaching the rest of us. Keep up the great work bro 👍🏻
@ppomm
@ppomm 6 місяців тому
Another video where you show what an excellent instructor you are Jost. Lots of detail, clear explanations but yet you keep it moving. I will say that in the elec business a 50A range outlet is x dollars but if you say it''s for an EV it always seems to be 2x dollars lol. Good explanation of why an industrial grade plug is worth the extra money. Thanks for sharing your skills and knowledge!
@AdamS-lh2ug
@AdamS-lh2ug 4 місяці тому
I’ll give him credit for that. It’s worth the extra money for quality plugs.
@markjoppru8015
@markjoppru8015 3 місяці тому
Great job. Appreciate the overview and detail
@ViktorVargas-jw2ut
@ViktorVargas-jw2ut Місяць тому
Great video u literally walked thru every step very helpful
@marif6598
@marif6598 Місяць тому
You explained everything so well. Excellent video.
@AdamS-lh2ug
@AdamS-lh2ug 6 місяців тому
Don’t wrap your ground counter-clockwise like he did in this video. If you watch closely as he tightens the ground screw it pushes the wire out of the screw. ALWAYS go clockwise when you wrap your wires. This goes for receptacles, and literally everything you wire.
@crisestrada9341
@crisestrada9341 6 місяців тому
Very true, I was about to say something about that as well.
@reginaldnoe5613
@reginaldnoe5613 5 місяців тому
Yep.... one of the first things pointed out to me when first learning to wire recepticles
@802Garage
@802Garage 5 місяців тому
If you noticed, it's a loop, not a hook. Therefore, it's "wrapped" in both directions. Even if he wrapped it the other way to make the loop, it would be the same U shape around the ground screw. Think about the physics. What he did is just fine. The only difference is which side of the loop gets wound tighter and which side gets loosened slightly. You could argue it's slightly better to have the length going to the receptacle tighter because it's going to get moved around, but in practice it will likely have the same impact either way.
@josephphillips1777
@josephphillips1777 5 місяців тому
Or use the pre-made ground tail and "pigtail" your grounds together
@BTW...
@BTW... 5 місяців тому
@@802Garage Bullshit. As the faster tightens it naturally unwinds the loop. Any movement has the wire detach.The terminal is of such poor design, having no means of restraining wire moving from under the fastener. Every trade qualified professional electrician knows this... yet you think it's all A-OK.
@devontrebarlow5980
@devontrebarlow5980 Місяць тому
Man thank you!! This was very informative and helpful! Exactly what I needed!! 💯
@michaeltablet8577
@michaeltablet8577 6 місяців тому
Your videos are always helpful. Thank you very much!
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Fantastic! You are very welcome. I appreciate you watching my videos!
@grzegorzlecki3139
@grzegorzlecki3139 5 місяців тому
your videos are so well done and informational. Keep up the great job!
@rontiemens2553
@rontiemens2553 6 місяців тому
Excellent presentation by the Excellent Laborer!
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Thank you so much! I’ll try to make all of my videos, helpful and useful. I appreciate you watching.
@optech69
@optech69 Місяць тому
Excellent. Thank you for lending your genius.
@Berrugasnoquiero
@Berrugasnoquiero 20 днів тому
thanks for the awesome video , very thorough and simple!!!!
@fuegoman45
@fuegoman45 6 місяців тому
Great stuff as always!! Thanks brother 🤙
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Thanks a lot for tuning into the new video! You are welcome. Take care!
@carloslagunas859
@carloslagunas859 2 місяці тому
Nice explanation. Thanks I just learned, how to wire a 240..
@sjpropertyservices3987
@sjpropertyservices3987 6 місяців тому
Thank you for sharing. Getting ready to install 14-30 generator inlet and process will be similar.
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
You are welcome! Oh yeah, definitely similar. Good luck with your project!
@dankelley9361
@dankelley9361 6 місяців тому
Josh, excellent descriptive YT video on installing a 50 amp outlet for a EV charger. I would let the viewers know that the 6 nomenclature on the 6-3 wire stands for the AWG or gauge of wire needed to withstand the 50 amp current draw.
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Thanks a lot, Dan! I did explain what AWG was in my last video. You’re right, I would have not heard to mention it again. Thanks for watching!
@ScotianCanadien
@ScotianCanadien 2 місяці тому
Production quality on your videos, your instruction, your concise communication and your overall knowledge are all very impressive. I'm going for a career change at 32, and have been watching all of your electrical videos ahead of getting an apprenticeship. Thanks a ton for these
@jeffreyschnabel7536
@jeffreyschnabel7536 17 днів тому
Awesome installation covers everything
@sudokillall
@sudokillall 3 місяці тому
I'm now gonna like this video because it was detailed and informative
@greg.montelione
@greg.montelione 2 місяці тому
Excellent video instruction of how to rough-in and install a 240 v outlet. This was extremely thorough and very concise. I feel confident that I could now undertake this work on my own. The only two questions I still have are; 1). What size mudring should be used depending on the thickness of the drywall? and 2). Why not use a two gang box to eliminate the need for the mudring? I think part of the answer is what you said about the mudring providing more room in the ox. I get that there is only one device and not two switches or outlets that would require a two gang box but the two gang has the four ears or tabs you'd need to secure the device to the box. Is this just a preference thing or is there another reason for this? These are sincere questions. I'm not being critical. I know enough to be dangerous and just like to have all of the information before undertaking work. Either way, I'm going to follow your lead thinking that if it's good for your house... then, it's good for mine. I'm asking in the event you respond before I've started / completed the work. Thanks in advance and all the best to you. Keep up the good work. 👍
@zekenzy6486
@zekenzy6486 6 місяців тому
Great Video and information . Thank you for sharing
@leagarner3675
@leagarner3675 6 місяців тому
Exactly what I needed to know. Thanks!
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Excellent I’m glad the video was helpful for you! Thanks for watching!
@ericfraser7543
@ericfraser7543 6 місяців тому
13:30 Like you said not all NEMA 14-50 outlets are the same, I would add that the duty cycle of an EV charger can be drawing 50 amps continuously where a standard range outlet was designed to handle the intermittent duty cycle of a range.
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Yes, good point! The long term continuous draw justifies having an industrial grade outlet versus a range outlet. Thanks for your input!
@Lou-jf4rl
@Lou-jf4rl 6 місяців тому
I installed mine the same way with the same receptical concerns. I also under sized my load to 40 amps because I was concerned about heat created by impedence with such a continuous draw over a 2-3 hour period. I used romex 6/3 due to electrical code but I think that other cables may be better at heat dissipation.
@TM-td7vk
@TM-td7vk 5 місяців тому
Your description should had said how to Install a 120/240 EV Charging circuit. In most units the neutral Is not needed but good to have for future use.
@vicb6019
@vicb6019 6 місяців тому
Great Video new subscriber from San Diego
@TheBlacksun24
@TheBlacksun24 Місяць тому
Excellent job on this video!
@KevinCoop1
@KevinCoop1 6 місяців тому
Excellent video and explanations. Technically you installed a 120/240 volt outlet. For those that do not want to spend $90 for the receptacle, Bryant (owned by Hubbell) same exact device is approximately half price. Why cheaper? If Hubbell can get named in the specifications for a large project, then higher profit. They bought Bridgeport out in 1991 which makes the Bryant devices. Never use cheap receptacles for car chargers. They overheat.
@LuLu_World
@LuLu_World 4 дні тому
they did not buy bridgeport. bryant was located in bpt ct
@802Garage
@802Garage 5 місяців тому
I have watched A LOT of these tutorials and done A TON of research into the actual code provisions pertaining to 240V receptacle installs. This is the first video I can point to that is essentially mistake and code violation free. The only exception being GFCI protection, but we all understand why you didn't go that route, hahaha. Awesome job! Will be my go to video to share with others looking for good info.
@TheExcellentLaborer
@TheExcellentLaborer 5 місяців тому
I always try to make my videos as accurate as possible. I’m glad you enjoyed this installation. Thanks for watching!
@BTW...
@BTW... 5 місяців тому
Your wrong about the "mistake free" content here.
@802Garage
@802Garage 5 місяців тому
@@BTW... Point out the mistake then or your comment is completely worthless.
@deang5622
@deang5622 5 місяців тому
Clearly it is more than just meeting code. See my post on the use of the knife to strip the wires.
@802Garage
@802Garage 5 місяців тому
@@deang5622 I'm not going to go through the entire comments section to find your specific post. If your biggest issue with this video is how he strips off the wire sheathing, I rest my case. You'd be friggin' amazed to see how many electricians do it. 99% of DIY people watching this video are not going to have Romex strippers. This is one of the best and most complete videos on the topic for sure. You can find something wrong with anything if you try hard enough. Nobody is going to have every single piece of information perfect and give every piece of advice possible.
@garyt534
@garyt534 6 місяців тому
Just to be clear, Torque specs are in inch pounds not foot lbs. Also, it's best practice to use a proper wire stripper instead of a razor blade, that way you won't risk nicking the conductor with the razor blade.
@davidhall3747
@davidhall3747 2 місяці тому
As an Automotive Technician I noticed that mistake too. Inch pounds and Foot pounds are two different tightening specifications.
@paulcrumley9756
@paulcrumley9756 Місяць тому
Newton-meters, too. And in my industry (aviation), there are approved wire strippers that must be used to avoid the likelihood of a violation. I'm surprised how many youtube experts use what would be unapproved tools to strip and crimp wires. Those tools are not excessively expensive, and with them it's almost impossible to harm the wiring or make a connection that is subject to loosening and arcing/catching fire. . .if it's good for a Boeing it's great for my house and vehicle.
@doatoolate.1250
@doatoolate.1250 6 місяців тому
Thank you for your knowledge. I wish I could worK with you and learn all you know.
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
You are welcome. I’m glad you’re finding my content helpful. I make videos on everything I do DIY. If you watch my videos, you’ll learn most of everything I know. Stay tuned for more!
@ayubbuildingconsultants
@ayubbuildingconsultants 6 місяців тому
Awesome and detailed video as always Josh. Thanks a lot. Was going through your kitchen cabinets video recently and have a question. What is their material ? (MDF/Plywood/Chipboard/Solid wood etc.)
@dunasingh8653
@dunasingh8653 4 місяці тому
Super great video. Thanks a lot.
@agray103
@agray103 6 місяців тому
Great video! Thanks for sharing 😊
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
You are welcome. Thanks for watching!
@dillardnorg
@dillardnorg 2 місяці тому
GREAT VIDEO! THANK YOU, THANK YOU, THANK YOU!
@PatrickEArchuleta-fs8bv
@PatrickEArchuleta-fs8bv 2 місяці тому
Thanks God bless outstanding work.Bottom line.
@AdamS-lh2ug
@AdamS-lh2ug 6 місяців тому
Also, if you have side cutters or really your strippers, you can score the romex and rip it without damaging the wires, you get a much cleaner look in your panel. Strip your wires before going into the panel.
@mikekennedy3173
@mikekennedy3173 2 місяці тому
Thank you Fantastic video.
@pizzapalmito
@pizzapalmito День тому
Thanks for your channel
@sma92878
@sma92878 6 місяців тому
Your videos are amazing, awesome content.
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Thank you so much! I appreciate all my subscribers as well. Take care!
@ashwanijangra
@ashwanijangra 19 годин тому
Thanks for the great video @theexcellentlaborer In my main panel there is only ONE bar, don’t have separate for ground and neutral. Can I connect both the wires on this single bar at random empty space? Please guide. Thanks
@peterchow4577
@peterchow4577 6 місяців тому
Thanks Josh another great video. Just want to know if you have the link for the torque screwdriver? 👍
@adolfolopez5772
@adolfolopez5772 2 місяці тому
Muchas gracias siempre veo tus videos.saludos from Norwalk california.
@user-tf1xg5wo8n
@user-tf1xg5wo8n 6 місяців тому
Thank You. very helpful.
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
You are welcome. Thanks for watching!
@cfrcrd5759
@cfrcrd5759 4 місяці тому
I thought the video was well done. You were precise and step by step. Sure, you always wrap a wire the way the screw screws in and I usually use a wire stripper in stead of a utility knife to strip the casing but still a well done video. Thanks.
@wick1952
@wick1952 6 місяців тому
Great job 👍👍 thank you 👍
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
You are very welcome.I appreciate the compliment!
@user-cw8rw8ug3k
@user-cw8rw8ug3k 2 місяці тому
Nice explanation
@yorkie1792
@yorkie1792 4 місяці тому
Thx. 29:49 was very helpful with all the supplies needed. No sure of the length of the 6'3 wire that I need
@paulroberts2549
@paulroberts2549 5 місяців тому
Great job.
@wlit
@wlit 4 місяці тому
Thank you for the video. Can you provide the link to the cover at 5:38 what will work on the Hubbell 14-50 Outlet?
@ChargePointnet
@ChargePointnet 6 місяців тому
Hey, thanks for the shoutout ⚡We make home charging simple and easy for every EV!
@greg3296
@greg3296 6 місяців тому
Very well explained
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Thank you, Greg!
@keithharrington8715
@keithharrington8715 5 місяців тому
Josh, you do a good job with your videos. On this one, i would like to stress several things. Since this is a subpanel install, the entire panel can be deenergized at the main panel. This should leave zero power in the panel. Yypu did what i would do, but like you i have a high electrical comfort level. You did this but did not stress it.....connect away from the panel first. This prevents anyone "helping" from powering the wires in your hand if they are not connected in the panel yet. Connecting the wires ground first, then neutral, then hots provides a small level of safety and is a prefered connection order. I will reference the 2020 code. Yes it updates every 3 years, so your jurisdiction may be several cycles behind and some requirements may not apply to your jurisdiction. Section 90.4 allows your local jurisdiction to accept all, some, or none, of the code. They can change requirements as they deem needed. Section 110.14. C. Electrical connections, temperature limits. Puts breakers 100 amps or less at the 60 °c rating for wire current unless the breaker is marked differently. This means the wire you use is rated under the 60° c column of the ampacity chart.(310.16). Yes, thhn is rated at the same as romex. The #6 copper wire is rated at 55 amps, not the thhn rating of 75 amps. 210.8 (A) gfci protection for dwelling units has upped the voltage to 250 volts or less receptacles require gfci protection when in garages, laundry areas and accessory building at ground level and not a dwelling. Yes, welder and car receptacles. 314.4 requires metal boxes be grounded.....yes the green screw. Again a safety feature, should the hot wires touch the metal box, it will cause the breaker to trip through the ground wire and prevent the metal plate covering it to be 120 volts. Now for the scary one. There is a seperate section for car charging (EVSE).section 625 with specific requirement. 625.40 points to one outlet (charger) on one breaker. 625.41 points to the circuit being 125% of the load. 40 amps of charging on a 50 amp circuit. 625.54. This is the gfci protection if you install a receptacle. This is not a hard install as Josh has shown, just make sure you follow the rules. Good luck.
@rorm12
@rorm12 17 днів тому
Thank you for the great video! I just have a concern about the Leviton 14-50 Plug used. I keep seeing vidoes of how bad of a plug it is and it causes fires. A lot of folks including Tesla is saying to use Hubbel or a Bryant Plugs instead. I just wanted to get you thoughts on it.
@Amer-yl4gb
@Amer-yl4gb 5 місяців тому
Great information video. I notice 1 mistake and that was you installed the 3/4 cable clamp backward. The screws for the clamp has to be inside the box. This is because incase in future they need to get more wire inside box on a finished wall they can loosen the screws and pull some wire inside the box.
@JohnThomas-lq5qp
@JohnThomas-lq5qp 5 місяців тому
Wrong. Two screw connectors should have the screws on outside of the box. Don't think inspectors like your way. With NMB cable stapled within 12" of a box next to impossible to pull in more wire.
@Amer-yl4gb
@Amer-yl4gb 5 місяців тому
@@JohnThomas-lq5qp lol please dont make things up out of the blue. This has nothing to do with the inspector, this is about the design engineering and proper function. First of all it doesnt matter what inspector likes or doesnt like. As per code, a cable must be secured to the box by the method the manufacturer of device/fastener has specified. 2nd of all, USUALLY (but not a requirement), a GOOD electrician will leave a slack of wire in the form of S between the box and the staple. A house lives for 100 years and during this time if someone mess up wires when connecting the devices, they'd have the option to pull in some slack into the box. A good example of this is the plastic push-in connectors for NMD wires where you can pull wires into box but not out. 2nd example is the regular NMD respectable boxes with the screw inside the box to secure the cable.
@JohnThomas-lq5qp
@JohnThomas-lq5qp 5 місяців тому
Did you ever have a job inspected? The inspector or AHJ has the final say. With 12/2 costing what a $1 a foot a little over a year ago no electrician will install stupid money wasting S bends for cables entering a box. The NEC mandates a support within 12" of boxes feed with NMB cable so that makes it very difficult to make a S bend and provide the 12" support. Metal box manufacturers never supplied type of connector to be used in their boxes. There are over a quarter Millon words in the NEC and hundreds of exceptions to all of the articles and like I have been told at the over 100 continuing education classes that I attended to renew my electrical license is if you ask 3 inspectors you might get 4 answers. The few times that I objected to an hick prima Donna only inspector in a little town that attempted to write me up for code violations I won out. Best was after my inspector passed a job local hick tried to I give me a violation for making a single splice on a 14 gauge wire inside if a circuit breaker panel. After I gave him the NEC article that allows it told me that he would let me get away with it that time. After many years still learning.
@Amer-yl4gb
@Amer-yl4gb 5 місяців тому
@@JohnThomas-lq5qp I do agree with you... with the copper prices after Covid no one is doing that S thing anymore. I learned that when I was a kid doing construction jobs here and there. But we do electrical cabinets for manufacturing segments. Complying with residential codes is child's play compare to industrial codes and regulations. I personally done 2 full basements and 3 house renovations jobs so far... maybe I was lucky I haven't had a jerk for a inspector... and yes like you said there been time when the inspector has said "you can't do this" and I told him yes I can and here's what the code says and then he would ok ok fine but I wouldnt do it like that... and moved on to the next item... inspectors just verify your are up to the code and if your are then it doesn't matter what he personally feels about your job.
@Amer-yl4gb
@Amer-yl4gb 5 місяців тому
What led me to this video was out of frustration in fitting a 14-50 receptacle in a 2-gang box. Usually a 4-11/16 box is used like the oven. But I wanted to minimize the drywall damage in the already finished garage and the fact that the receptacle bag said use a 2-gang box. Now when I was trying to wire 6/3 cable to it and intall it, the receptacle plate bent. So I wanted to see how others do this 😅. Anyways I cut the wires much shorter and pre bent wires and that still was hard to install but it went in fine.
@MitchellRose-gi2ln
@MitchellRose-gi2ln 13 днів тому
Great! Much thanks.
@blackhorse2947
@blackhorse2947 13 днів тому
I have a wood lathe that runs on 220v. I have moved it to a better location in shop, unfortunately the power cable will not reach it now. The lathe now is 6fr from the existing outlet. Can I daisy chain from the existing location to the new receptacle or home run from power panel. I never run any of my 220v machines at the same time. I would appreciate your thought, and I am a new subscriber…. Enjoy your excellent videos
@anthonyesparsen9453
@anthonyesparsen9453 Місяць тому
I'm your code expert recently retired 25 year's of service 60,000 inspections under my belt
@sjpropertyservices3987
@sjpropertyservices3987 6 місяців тому
Thank you!
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
You are welcome!
@thelosteddies
@thelosteddies 3 місяці тому
Who needs an electrical license when you have UKposts😂
@Tom-mu7zy
@Tom-mu7zy 2 місяці тому
In Colorado, you can get a home owner's electrical permit, do your own work in your own house or garage (non commercial) call for an inspection and you are legal.
@huestifer
@huestifer Місяць тому
Famous last words. R.I.P.
@michaelstora70
@michaelstora70 4 місяці тому
Recent code revisions require GFCI outdoor or in garages above 20A but that is only for branch circuits (welder, range, EV charger) but it is not allowed on feeder circuits (RV outlet--anything with a subpanel). The same 14-50P could be either.
@anthonyesparsen9453
@anthonyesparsen9453 Місяць тому
Don't forget follow local NEC codes where gfci and arcfault protection may be required
@2314814d
@2314814d 5 місяців тому
Thanks!
@TheExcellentLaborer
@TheExcellentLaborer 5 місяців тому
I appreciate the support!
@thomaslopez155
@thomaslopez155 2 місяці тому
❤it man u are a LIFE SAVER.JYST BOUGHT A HSE AND MAN THEY DUD A $,U AND AVE SAVED ME THOUSANDS. AND YES MY POPS INSPECTOR....COOL BROTHER U KEEP TEACHING ME.THAN KG S AGAIN. ❤IT
@charliefraser793
@charliefraser793 6 місяців тому
Nice job hard worker
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Thank you for the nice compliment!
@charliefraser793
@charliefraser793 6 місяців тому
@@TheExcellentLaborer your welcome your nice guy
@anthonyesparsen9453
@anthonyesparsen9453 Місяць тому
I'm seeing pretty much all you advising electrical outlet wiring with out basic requirements
@CLTNY1
@CLTNY1 6 місяців тому
Excellent.
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
I appreciate that!
@novamaggart3251
@novamaggart3251 6 місяців тому
Excellent video. Would you mind sharing which torque screwdriver you used in this video? I did not see it mentioned in the list of tools used in this video. Thank you. Also, did you really torque the screws to 75 in-lbs?
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Thank you! I’m not sure the exact brand of the screwdriver because I borrowed it from a friend for this install. I had the dial pass 70 to get the torque which should be around 75 lbs. I hope that helps!
@andrewallen8764
@andrewallen8764 3 місяці тому
I want to run one of these 6/3 14-50 plugs outside for an RV Do I use Metal conduit or Plastic?
@TheHearseAroundJimThorpe
@TheHearseAroundJimThorpe 5 місяців тому
If I want to put in an oven and a dryer those have to be 2 separate 240 V circuits correct?
@anthonyesparsen9453
@anthonyesparsen9453 Місяць тому
Don't bypass your NEC requirements for new 220 install requirements like GFCI/arc fault per 218.8,210.12
@stuartmarkman769
@stuartmarkman769 4 дні тому
I was tought too wrap wires clockwise around screws so they stayed tight and didn't spread out. It just works better. Torque is rated in inch or foot pounds. The wire screws are tightened too INCH pounds.
@tonylozano8574
@tonylozano8574 2 місяці тому
Great video, I've learned a lot and it's information what needs to be done, but I won't do it. I'm thinking of buying an EV, but how do I assess If I can install another 240 volt outlet? For me, to call for a electrical assessment it will cost about $300. I live near San Francisco. So how do I assess my electrical box?
@joejoeaz47
@joejoeaz47 21 день тому
Is it code to use the 6/3 exposed on surface mount?
@kennies5925
@kennies5925 5 місяців тому
I followed the example precisely, testing the outlet with a multimeter revealed 110 volts on both neutral/ground and hot (black or red) independently, and 240 volts across. However, when I plugged in my Tesla mobile connector, it initially seems to receive electricity, but then displays a red 'T'. Any idea what I might be doing wrong
@richstarstar
@richstarstar 6 місяців тому
Good job. Love the video. how did you estimate the length of the run so good. You had a drawing to work from or you just use a tape measure and guestimate?
@TheExcellentLaborer
@TheExcellentLaborer 6 місяців тому
Thanks! I’m glad you love the video. I use a 100 foot tape and then run it where the wire will be installed. I simply just use that measurement to buy the length of wire. I hope that helps!
@richstarstar
@richstarstar 6 місяців тому
Thanks for the response. @@TheExcellentLaborer
@dmark6699
@dmark6699 3 місяці тому
Very Good.
@TheExcellentLaborer
@TheExcellentLaborer 3 місяці тому
Thank you!
@treyblack9736
@treyblack9736 3 місяці тому
Is the ground wire still connected to the box? It looks like it’s no longer connected when you started connecting it to the plug.
@royrodas6704
@royrodas6704 5 місяців тому
good job I like it I want to become a teacher like you
@N.I.C.K.
@N.I.C.K. Місяць тому
Is the metallic faceplate grounded simply when connected to the Hubbel Nema 14-50 receptacle? Or does the faceplate need to be grounded separately?
@802Garage
@802Garage Місяць тому
Did some digging to try to make sure I answer accurately. Yes the faceplate is required to be grounded, of course, but yes the mounting screws should be considered sufficient by code to be a proper bond to ground. It's generally not very specific about this, perhaps because it seems obvious, but there is specific code pertaining to medical facilities which permits this, at the least. The faceplate is grounded by the receptacle which of course must be grounded. The receptacle is also touching the box which must be grounded even if the receptacle is removed. The faceplate is grounded both by physical to any metal components, but most importantly by the screws.
@serhammalot01
@serhammalot01 13 днів тому
what does it mean if it says 230v? I want to install a 230v mini split using my 50 amp rv park plug since I have the rv plugged into the 30 amp. Would this work?
@gillesbourbonnais4805
@gillesbourbonnais4805 2 місяці тому
Thank you for the explenation but I will get an electricent rader go safe 😑 from Québec Canada
@KeiganApparel
@KeiganApparel 2 місяці тому
What kind of torque screw driver are you using???
@onlyulee866
@onlyulee866 Місяць тому
The name plate on my range calls for 11.3 kw. What size of the breaker do I need
@anthonyesparsen9453
@anthonyesparsen9453 Місяць тому
Most of these new 220 outlets require gfci and maybe afci protection per nec
@joseharo3273
@joseharo3273 5 місяців тому
Great video just wondering how much an electrician must charge for a job like this
@ShamelessHellions
@ShamelessHellions Місяць тому
For EV supply equipment, direct wire is the way to go. Much less possibility of the equipment melting down vs the cord and plug method. Also, you would avoid an unnecessary expense of the outlet. The cheap leviton outlets are fine for a range, but are a legit fire hazard on EVSE. The wire used for direct wire will save some $$ as well. EVSE use 2 wire with ground and don’t require a neutral. I do like how this installer used a torque screwdriver. Properly torquing the terminals are important for every install (just look at manufacturers instructions), but especially when there is a significant current draw.
@Cdswjp
@Cdswjp 5 місяців тому
Regarding the 6-3 wire’s ground wire which was wrapped around the green screw & screwed against the two gang box via that same green screw: this is the same ground wire that’s then run into the outlet, right? Just curious Thank you
@TheExcellentLaborer
@TheExcellentLaborer 5 місяців тому
Yes, the wire going to the green screw continues to the outlet. I hope that helps!
@Cdswjp
@Cdswjp 5 місяців тому
@@TheExcellentLaborer indeed. Much obliged 🎩
@LarryRichelli
@LarryRichelli 4 місяці тому
I was disappointed that the torque screw driver was not listed in this video or on you Amazon parts page.
How To Install A Flood Light - BEGINNERS GUIDE
8:33
The Excellent Laborer
Переглядів 9 тис.
DIY WELDING OUTLET.....Step By Step Installation By An Electrician
22:39
Spicer Designs
Переглядів 190 тис.
Can You Draw The PERFECT Circle?
00:57
Stokes Twins
Переглядів 41 млн
😨Новая Война в GTA 5 Online #shorts
00:40
King Dm
Переглядів 1,7 млн
How To Install a 240 Volt Outlet | Electric Car Charging
48:44
Everyday Home Repairs
Переглядів 2,5 млн
How to Install an EV Charger - Legrand Hardwired Level 2 EV Charger
25:25
Mad Electrician
Переглядів 36 тис.
Plug 2 wires 12 / 2 romex
5:56
Juan Chavez
Переглядів 45 тис.
3 Mistakes I Made Installing a NEMA 14-50 Outlet
9:53
Josh Charles
Переглядів 317 тис.
How to use a multimeter like a pro, the ultimate guide
12:55
James Gatlin
Переглядів 1,4 млн
Installing 220v Outlets in the Shop - Easier Than You Thought
7:51
Jonathan Katz-Moses
Переглядів 2 млн
Кулинарный лайфхак с лепешками #shorts
0:49
ПавЭл Сажин
Переглядів 1,4 млн
Никто не помогал ему😢
0:30
Фильмы I Сериалы
Переглядів 2 млн
Последняя надежда! Лезем в мотор BMW...
2:5:41
ИЛЬДАР АВТО-ПОДБОР
Переглядів 3,8 млн
О, сосисочки! (Или корейская уличная еда?)
0:32
Кушать Хочу
Переглядів 2,7 млн
河东狮吼
0:13
曹操大哥
Переглядів 13 млн
Constipation - 3d animation  #meded #anatomy #3dmodel
0:21
SciePro
Переглядів 57 млн
СТРИЖКА ЗА 10 000$😱 #истории #стиль #стрижка
0:45
АРХИВ ИСТОРИЙ
Переглядів 9 млн