Insane 3 Phase AFDD Distribution Board

  Переглядів 21,833

Mike Page

Mike Page

Рік тому

In this video I'm building the most advanced 3 phase distribution board I've ever built.
If you enjoy electrical content please subscribe to the channel and checkout my links below 👇
T r a d i f y 💻
bit.ly/3y9nxV9
M Y W E B S I T E ⚡
residualcurrent.com/
M Y L O A D O U T 🛠️
residualcurrent.com/pages/loa...
B I G B O O T S D I S C O U N T 🥾
bigboots.co.uk/?ref=4s3760y77o - Use code RESIDUAL
U N I L I T E D I S C O U N T 🔦
unilite.co.uk/?ref=RESIDUAL - Use code RESIDUAL
J O I N T H E C H A N N E L 🤝
/ @residualcurrent
I N S T A G R A M 📷
/ residualcurrent
T I K T O K ♪
vm.tiktok.com/ZM86U2jjG/
The works carried out in the video and the opinions shared are my own, and not representative of the associates and companies in the video.
This content is purely for entertainment purposes and is in no way a "how to", tutorial or educational video.
Please consult an electrician when dealing with any electrical installations.
#electricianlife #electrical #electricalengineering

КОМЕНТАРІ: 50
@garyu353
@garyu353 Рік тому
Schneider is a class board! Work with them all the time. Only negative from me is, would love them to have one big gland plate and not two separate ones on some of there boards. Keep up the good work mike!!
@danielelise7348
@danielelise7348 Рік тому
Love the way the terminals are dead until a breaker is inserted, awesome design,they seem to have thought of just about everything.Love the videos Mike, work safe,cheers from Australia.⚡🎆🔌
@GaryB1980
@GaryB1980 Рік тому
Great video nice one. Love all the content lately, keep it up. 😎
@edglue6138
@edglue6138 Рік тому
Great video Mike. Technology is great
@TradifyHQ
@TradifyHQ Рік тому
Love this! Glad you're enjoying Tradify.
@j22_wys51
@j22_wys51 Рік тому
Your actually the best of the best on UKposts electricians wise such niche content, love it 😅
@timlarsen5014
@timlarsen5014 Рік тому
Brill to see you on the inside front cover of latest Professional Electrician & Installer magazine that I’ve just picked up from CEF
@cliveramsbotty6077
@cliveramsbotty6077 Рік тому
love a bit of schneider. use lots of their contactors and relays at work. i do wish they'd stagger the terminals though.
@electrician247
@electrician247 Рік тому
Proper board is that one Mike. Cracking video 💪
@paradieshenne
@paradieshenne Рік тому
Nice board, but why? I don´t understand why you are using these unflexible boards. Here in germany and I think most of europe aswell, we are using empty (and larger) boards with rows of DIN-rail where you can put on whatever you need. Not only breakers but a lot of different things (contactors, PLCs, timers, metering, monitoring, etc.) in any order. You can then just run everything to a row of terminal blocks and tie in there rather than running wires all around the board. (basicly its a electrical cabinet but with a faceplate like in a consumer unit so that its safe to use for a layman.
@tc6907
@tc6907 Рік тому
Because here in the UK the IET seem to think having the same brand of consumables is the only way….. 🙄
@ianmiller3182
@ianmiller3182 Рік тому
Surely a product standard wouldn't be able to cover every configuration ?
@mrfrenzy.
@mrfrenzy. Рік тому
This is exactly how we do it in Sweden aswell, it is very flexible and there is no problem mixing brands of components. I can see one advantage of the kind of busbar shown in this video - you can easily replace breakers without shutting off the main switch (sure you can do that in a DIN board aswell but not quite as safely).
@AS19283
@AS19283 Рік тому
Because our regs are strict in a good way sometimes and absolutely useless in others 😂 We are also very friendly to corporations that supply all the equipment. This one specifically is very rare but used in high high end installs that need built in monitoring etc.
@AGRElectrics
@AGRElectrics Рік тому
They do skeleton boards here some fit them but rarely. Look better and easier to fit a DB that's all one brand aswell no issue with fitting etc. 🤷
@yngndrw.
@yngndrw. Рік тому
I do like the Schneider boards but I wonder why the Active AFDDs require a new set of terminals rather than using the existing Isobar P plug-on-neutral system that they use for their RCBOs, or at least the distributed neutral bar so that they can support the standard Isobar boards.
@ukbullylife7968
@ukbullylife7968 Рік тому
Schneider the best I think and that’s the most hi tech board I’ve seen out of that range. I’ve been using the Eaton cable interface kits saves cutting pax or any other board the size fits most 3 phase db’s
@millieh3179
@millieh3179 Рік тому
Board building videos are my new favourite thing.
@TheHomeent
@TheHomeent Рік тому
Another fantastic video
@CourtesyOfBR
@CourtesyOfBR Рік тому
hey bro, can you please pls pls do a video of setting up and wiring a 3 phase board, just cant find no videos based around the uk with good quality and explanation,
@effervescence5664
@effervescence5664 Рік тому
We don't tend to fit Schneider (Eaton is the go to spec for clients) but I have a refurb coming up that needs new boards, I'll be watching this series and probably contacting Schneider UK about getting hands on as these look ideal for what the client has in plan for the site.
@kjgreen3
@kjgreen3 Рік тому
Fun fact the old Eaton site in Doncaster had only Merlin Gerin and Brand new schneider DB's. Spoke to maintenance guy and said. " Why don't you use the switchgear you make here?" His reply. "It's shite"
@effervescence5664
@effervescence5664 Рік тому
@@kjgreen3 I can believe that, the older stuff was shite and I'm still not happy with Memshield3 and the newer stuff. Their Bognor site is all their own stuff last time I popped in though. This Schneider board has me intrigued though and I've heard good things from multiple sources so far so willing to swap.
@jonesconrad1
@jonesconrad1 Рік тому
Yay a proper length video.
@steveokinevo
@steveokinevo Рік тому
Schneider and hager for me, good vid bro.
@TradieTrev
@TradieTrev Рік тому
That's pretty damn flash that busbar. I wonder how the plastics will go in 20 years time.
@anthonybragg
@anthonybragg Рік тому
I think they have gone downhill slightly since Schneider took over, but so have other manufacturers. What was those blue dots on part of the distribution board? not seen them before. brilliant video again Mike.
@harnoorsingh1809
@harnoorsingh1809 6 днів тому
Blue dots are to indicate Neutral because those points are dedicated to fix AFDD's
@1992Craigster
@1992Craigster Рік тому
Problem with the "wireless" rcbo is its single pole, to go dp you need to use two ways and the neutral extension bar. Also for 3 phase feeds you now need a vigi unit which swallow up ways.
@iotelectrical
@iotelectrical Рік тому
They do a 3phase RCBO now that only takes up 3 ways
@1992Craigster
@1992Craigster Рік тому
The A9D17316 is not compatible with those board SEA9BPN12 boards. The busbar arrangement is officially incompatible, although I imagine it would fit.
@AS19283
@AS19283 Рік тому
One thing that’s become such a ‘thing’ is proper torque levels in DBs. But equipment isn’t checked for torque? And how often do torque screwdrivers need calibrated? And who pays for this? The employer? Not questions for you really Mike, just for discussion as I actually don’t know!
@travishamilton1659
@travishamilton1659 Рік тому
I'm a sparky from the United States man and I love your videos
@FNUKSTER1366
@FNUKSTER1366 Рік тому
Great boards to terminate, but however built like tin foil , always swop the bottom panel with the top as the 8 20mm cutouts are to close together for armoured cable's , drill your own , and hanging a 95mm 4 core bends and mis shapes the bottom
@Key_Capz_
@Key_Capz_ Рік тому
Nice👍
@godverdommekut1
@godverdommekut1 Рік тому
More!
@arcadia1701e
@arcadia1701e Рік тому
Mmmm why the fused main switch? Why not an mccb?
@david-ip9cm
@david-ip9cm Місяць тому
No part 2? :(
@timn9622
@timn9622 Рік тому
Only thing I don’t like about these DB’s are the covers, bit flimsy and heavy when you can’t remove the door. I much prefer the Eaton cover where the door is removable.
@travoltasbiplane1551
@travoltasbiplane1551 Рік тому
sway-do? you got your niceic inspection or something? 🤣 nice board. 👍
@raymondestrada6434
@raymondestrada6434 Рік тому
nice
@ricksanchez9669
@ricksanchez9669 Рік тому
ahhh another thing i have to learn an entire new section of english to even begin to understand.
@helmanfrow
@helmanfrow Рік тому
So the UK finally has a systematized panel board with built in bus bars. I guess Siemens has had stuff like this for a while in the UK but you never see anything like it on UKposts residential install videos. The two things that always baffle me about UK electrics (besides the lingo) are a) the tiny size of residential main panels (at least as I perceive it on UKposts) and b) that you need to use a copper bus bar because it's not systematized. Also weird is that the bus bars you use are uninsulated along the spine. Just a bare-ass piece of copper carrying the totality of the line load, just hanging out under your breakers. No big deal.
@johnhoward2104
@johnhoward2104 Рік тому
Interesting video but there was too much of the side view of the board and flybying of the components. Given it was a construction video, would've been better to have seen more closeups of the components and in aerial views of the inside of the board i.e. to see what's going on inside the board. Also, there was the dreaded wobbly camera going on. Film directors opted for this a few years ago but got complaints about it promoting sea-sickness - I agree - it's awful, so give him a slap and tell him to hold the camera still - and if he can't do it, use a tripod! Looking forward to the next video.
@AS19283
@AS19283 Рік тому
Yeh, probably don’t slap him 😂 but a wee gyro mount would be a winner 👍
@johnhoward2104
@johnhoward2104 Рік тому
@@AS19283 for clarity, the slap was meant to be a joke - didn't mean to distress anyone.
@AS19283
@AS19283 Рік тому
@@johnhoward2104 I definitely got that, I was attempting to continue your humour but failed 😂
@ELECTRICLIFE4U
@ELECTRICLIFE4U Рік тому
👍👍👍👍👍
@jurassicsparks5220
@jurassicsparks5220 Рік тому
You should have triple the amount of subscribers with your content, Mike. I know it’s hard but a few 20 minute videos goes a long way.
Commercial Distribution Board Installation
28:13
Mike Page
Переглядів 21 тис.
Сын Расстроился Из-за Новой Стрижки Папы 😂
00:21
Глеб Рандалайнен
Переглядів 4,9 млн
0% Respect Moments 😥
00:27
LE FOOT EN VIDÉO
Переглядів 34 млн
3 Phase Distribution Board
17:43
John Ward
Переглядів 108 тис.
Galvanised Steel Conduit with ​⁠@corymac
28:54
Mike Page
Переглядів 37 тис.
Fitting a new 3-phase fuse board | Thomas Nagy
14:05
Thomas Nagy
Переглядів 89 тис.
Industrial electrical panel wiring training with all details
26:20
EMERGENCY Job Means One Thing (Earth Rods) - Electricians Life Uk
14:28
JRC Electrical
Переглядів 16 тис.
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Переглядів 2,1 млн
План хакера 🤯 #shorts #фильмы
0:59
BruuHub
Переглядів 1 млн
Broken Flex Repair #technology #mobilerepair
0:50
ideal institute aligarh
Переглядів 650 тис.
С Какой Высоты Разобьётся NOKIA3310 ?!😳
0:43
Koshyl_Live
Переглядів 537 тис.
Broken Flex Repair #technology #mobilerepair
0:50
ideal institute aligarh
Переглядів 650 тис.