JCC Have done it AGAIN! - Listening to electricians and creating the RADIALED RAPID LED Bulkhead

  Переглядів 11,379

eFIXX

eFIXX

День тому

An easy to install IP65 LED bulkhead which with loads of specification options.
In response to feedback from electricians' JCC have redeveloped the popular RadialLED range from the ground up. Available in a wide range of colour temperatures, control options and just about every conceivable mounting option.
Emergency lighting versions across every variant.
🕐 TIMESTAMPS 🕕
======================
00:00 The NEW RadiaLED Rapid from JCC Lighting
00:48 Unassembled out of the box?
01:11 Surface and rear entry cable entries
01:40 Dual entry cable grommet
02:00 Base mounted screwless terminal block
02:30 Double insulated - with earth termination
03:00 Gear tray retaining strap
03:30 Wide range of control options from microwave detector to a photocell
04:12 Clip in gear tray
04:45 Uniform light distribution
05:20 Range of clip o trim ring finishes
06:05 Smooth polycarbonate finish.
======================
== AD ===========================
🧰 More information
RadiaLED® Rapid LED Bulkhead
www.jcc.co.uk/en_GB/all-produ...
================================
📍SUBSCRIBE TO THE CHANNEL
eFIXX is here to help electrician's, electrical contractors, building services engineers and electrical apprentices. Watching our videos, you'll discover new products, explore new applications and find answers to your technical questions. So if you've been on the tools for years or just starting your electrical journey, then please subscribe. We'll help you stay up to date with the latest regulations and developments in the electrical industry.
ukposts.info?sub_con...
================================
📺 NEW TO THE EFIXX CHANNEL
Watch our essential videos playlist
• NEW TO eFIXX - ESSENTI...
================================
🎥 CATCH UP ON THE LATEST VIDEOS
ukposts.infovideo...
================================
🛠 ELECTRICIANS' TOOL REVIEWS
• Electricians' tool rev...
================================
🧲 EFIXX NEWSLETTER
Sign up to find out about our live events, competitions and product giveaways.
www.efixx.co.uk/sign-up
================================
📝 APPRENTICE HUB
If you're an electrical apprentice, retraining as an electrician or looking to refresh your knowledge, then please check out our apprentice hub. It contains thousands of multiple-choice questions to help prepare for electrical installation exams.
www.efixx.co.uk/apprentice-hub
=================================
SOCIAL
✅ INSTAGRAM - See our behind the scenes action.
efixx_insta...
✅ LINKEDIN - Latest electrical news and trending content.
/ efixx
==================================
❌ This content on this channel is for electrical professionals.❌
==================================
🎦 Presented by
Joe Robinson - Technical Editor
#efixx #lighting #morepower

КОМЕНТАРІ: 56
@andyrutherford203
@andyrutherford203 3 роки тому
WHAT!!! a fitting thats considering the actual practicalities of fitting, against gravity, up a ladder with with only 2 hands not the required 3? Whats going on? What happened to the fittings designed by a spotty A level design student whos never been up a ladder in his life but thinks it looks good with those piddly small screws and one small access hole for all the wires. Has the world gone mad?
@efixx
@efixx 3 роки тому
This could be the future of electrical ⚡️ product design!
@brianwood5220
@brianwood5220 3 роки тому
WoW, Well done JCC. Beautiful looking too.
@jccadvancedlighting
@jccadvancedlighting 3 роки тому
Thank you
@tommochelsea72
@tommochelsea72 3 роки тому
First a covid vaccine now this....wow what a day 😂👍🏻
@efixx
@efixx 3 роки тому
Next thing we’ll be able to pop out for a 🍺... triple win today
@muzikman2008
@muzikman2008 3 роки тому
Nice...
@alexdougherty4905
@alexdougherty4905 3 роки тому
Reminds me of when fern howard did the 'time in a box' fittings.
@greggsmith4539
@greggsmith4539 3 роки тому
Shut up burt
@AsadMulla
@AsadMulla 3 роки тому
Good fitting them
@alexdougherty4905
@alexdougherty4905 3 роки тому
@@greggsmith4539 you old jank. Get out of the comments 😂
@alexdougherty4905
@alexdougherty4905 3 роки тому
@@barnabybot the joys of facility management🙄
@abdullahseba4375
@abdullahseba4375 3 роки тому
These videos are great, but a nice addition would be your thoughts on build quality and the robustness of the product is. A lot of products, even from a reputable brand, tend to be 'plasticy'. Palazzoli Commando plugs vs ABB for example. Both good, but one instils a lot more confidence than the other.
@carlchambers1715
@carlchambers1715 3 роки тому
There not gunna be able to say its poor quailty on a paid promotion, they wont get paid 😂
@abdullahseba4375
@abdullahseba4375 3 роки тому
@@carlchambers1715 Are these paid?
@AndrewStrydomBRP
@AndrewStrydomBRP Рік тому
@@abdullahseba4375 Yes
@ShadowzGSD
@ShadowzGSD 3 роки тому
my only problem is push fit connections. always end up using connector blocks because there is only room for two wires in push fit, how often do you get live in, live out and switch when replacing fittings, and even worse when you get live in, live out, switch and loop on to another fitting.
@sbusweb
@sbusweb 3 роки тому
+LeicaGermanShepherd In this case, each of the 5 terminals has 4 connections available (2 each side) so ou CAN cope with feed-in+feed-out+switch on the existing terminal block.
@ShadowzGSD
@ShadowzGSD 3 роки тому
@@sbusweb i noticed, hence my comment.
@filipe.skunk8
@filipe.skunk8 3 роки тому
@@ShadowzGSD because a light fitting isn’t a junction box..
@johnburns4017
@johnburns4017 3 роки тому
What are you on about . Look again and stop the vid on the junction connections. If you have a Line in and out to the next light, then use the spare connection for the Line. From this to the light switch, then then back to the light to the Line that lights it up. All there. Easy. Push-fit connections are far safer than terminal blocks.
@ShadowzGSD
@ShadowzGSD 3 роки тому
@@johnburns4017 some people need to learn to read before posting stupid replies
@johnburns4017
@johnburns4017 3 роки тому
That is superb. I wish I had one a few months ago. On some similar LED fitting they have a switch that gives three types of light: cream, bright white and in between. Does this have that?
@jccadvancedlighting
@jccadvancedlighting 3 роки тому
John, thank you for your message. RadiaLED Rapid comes in 4000K colour temperature
@johnburns4017
@johnburns4017 3 роки тому
@@jccadvancedlighting Thanks. Switchable from the light assembly itself?
@bellas_switch_adapted_toys
@bellas_switch_adapted_toys 3 роки тому
In stock NOW at Eyre & Elliston Reading 😎🔥📢
@raychambers3646
@raychambers3646 3 роки тому
I thought you were supposed have an earth point at all outlets in a metal accessory was at a later date?
@charlieparish8353
@charlieparish8353 3 роки тому
The 4 holes in the middle. Are they for conduit boxes?
@jccadvancedlighting
@jccadvancedlighting 3 роки тому
Charles, thank you for your message. The 4 central mounting points are 55mm spaced for BESA conduit box mounting
@thattoolguy9432
@thattoolguy9432 3 роки тому
love the flexibility of the fittings, fantastic range of options .. but a plastic gear tray for led? what about heat dissipation? 1 year warranty i guess?
@jccadvancedlighting
@jccadvancedlighting 3 роки тому
Torchy, thank you for your message. The base and diffuser are polycarbonate. The LED Tray is PA6 Nylon and has been thermal tested. RadiaLED Rapid comes with an extended 5 year warranty.
@thattoolguy9432
@thattoolguy9432 3 роки тому
@@jccadvancedlighting brilliant, can't argue with that .. i used a similar looking fitting made by JCC for bathrooms in a new build.. nice light output .. i assume they come in 4000k ?
@jccadvancedlighting
@jccadvancedlighting 3 роки тому
@@thattoolguy9432 Yes, 4000k, thank you
@CoulterTravel
@CoulterTravel 3 роки тому
JCC would REALLY be thinking about us, if they included three terminals for CPC and neutral! What’s the point of those ‘spare ones’ why not just add them onto the earth and neutral for the common three plate method??!!! So close to being perfect, but so very far for that reason. I’m sure these companies think they’re lights are only connected at end of line or switch fed. So frustrating.
@neiltrevatt
@neiltrevatt 3 роки тому
How easy is the outside ring to get back off
@efixx
@efixx 3 роки тому
Not difficult at all, it snaps on secuely but you won't break a finger trying to get it off again.
@damonbtc9701
@damonbtc9701 3 роки тому
Oooooeeeeeeweehhhhhhh
@londontrada
@londontrada Рік тому
I like these but that terminal block goes straight in the bin. If they included loose wagos it would be perfect.
@crumps84
@crumps84 3 роки тому
If this fitting is all about being speedy, why was Gaz not doing it? Or would he have been too fast??
@efixx
@efixx 3 роки тому
He likes to build things from component parts
@ryanmilne1987
@ryanmilne1987 3 роки тому
The 4 screws let the fitting down, expecially when they have made everything else push-in and click on
@TheManLab7
@TheManLab7 2 роки тому
If your a sparky, you'll understand WHY they have to use screws.
@SALMR79
@SALMR79 3 роки тому
How much do they retail for?
@jccadvancedlighting
@jccadvancedlighting 3 роки тому
Thank you for your message, please contact your local wholesaler who will be able to guide you on pricing
@peterpeterson9903
@peterpeterson9903 3 роки тому
Jeeze - JCC utter tat imported from the far east, spec changes every couple of months as they find a new manufacture for a few pennies cheaper, terrible LED's, unbranded drivers. Terminals are even cheap knock-off Chinese versions. 100Lm per circuit watt, that is also shockingly low these days. Terrible lead times (waiting for a boat to dock!). Don't be fooled folks.
@mowcius
@mowcius 3 роки тому
They have thought of some useful things around install but I'd agree with the actual finished quality of the product not being any good. Philips produce an LED for Dubai that has an efficiency of 200lm/W now (shame you can't buy them anywhere else though). It's a shame that with labour being the biggest cost of most jobs manufacturers focus on time to install alone and selling an overpriced product to an installer rather than a quality product that would be better for the customer.
@JasperJanssen
@JasperJanssen Рік тому
Shame it’s using the shitty connector block. Those clamp between a spring and the plastic of the connector block, and when they were being tested in various places on UKposts like John Ward they melted at like 5 amps.
"Поховали поруч": у Луцьку попрощались із ДВОМА Героями 🕯🥀 #герої #втрати
00:15
Телеканал Конкурент TV - новини Луцька та Волині
Переглядів 97 тис.
REVEALED: The Secrets of an Arc Fault Detection Device AFDD
12:15
We should use this amazing mechanism that's inside a grasshopper leg
19:19
AMAZING TOOLS YOU SHOULD KNOW ABOUT
16:11
TechZone
Переглядів 59 тис.
BANNED: What the end of Fluorescent Tubes Means for YOU!
8:03
ЭТО САМЫЙ МОЩНЫЙ ИГРОВОЙ СМАРТФОН ЗА 270$ 🔥
13:33
Thebox - о технике и гаджетах
Переглядів 45 тис.
Start from 0 at any point on the T1 Digital Tape Measure
0:14
REEKON Tools
Переглядів 18 млн
All New Atlas | Boston Dynamics
0:40
Boston Dynamics
Переглядів 5 млн