SUNGOLDPOWER 3000W Pure Sine Wave Inverter Charger Test and Review

  Переглядів 76,385

James Condon

James Condon

День тому

SUNGOLDPOWER 3000W Pure Sine Wave Inverter Charger Test and Review
Sun Gold Power: sungoldpower.com/collections/...
Inverter Product Links:
sungoldpower.com/products/300...
amzn.to/3meOToD
www.amazon.com/SUNGOLDPOWER-I...
Visit My Amazon Store:
www.amazon.com/shop/jamescondon
00:00 Introduction
00:25 Unboxing
00:44 First Impression
01:26 Background
03:03 Features
06:03 Capacitor Charging
07:32 First Power up
08:50 Load Testing
13:44 Variac Testing
15:58 Conclusion

КОМЕНТАРІ: 367
@itsjustme1949
@itsjustme1949 2 роки тому
For those that don't know, MOSFET means metal oxide semiconductor, field effect transistor. Just in case you wanted to know.
@talusranch990
@talusranch990 2 роки тому
He doesn't know
@ToddDesiato
@ToddDesiato Рік тому
This is correct, and this inverter has just as many MOSFETs as any other. These are LV MOSFETs where the HF inverters use HV MOSFETs or IGBTs.
@eddietee6305
@eddietee6305 Рік тому
True. In other words it's a switch - electronic.
@VinceBadovinatz88
@VinceBadovinatz88 Рік тому
Thanks I don't know anything about mosfets
@VinceBadovinatz88
@VinceBadovinatz88 Рік тому
What is the idle consumption on the sun gold. I think it said 1.6 amps but I don't know how to convert that to watts.. I need to learn how to do that because they all come in amps well they don't all say amps. The all-in-one inverter 2424 mPP uses 50 watts, which is the only drawback to those. well I don't know about the only but that's the biggest one. I wonder what the 1.6 amps on this means
@RC-fu6hg
@RC-fu6hg 2 роки тому
That’s a super nice inverter. Thanks for showing it to us. I was hoping you had a gen-set hooked up and it was going to switch between the three modes of operation.
@jcondon1
@jcondon1 2 роки тому
Really wanted to do that. Believe it or not, I only have one with remote start at the moment and it was not comparable :(
@daver681
@daver681 2 роки тому
Good job on the testing of the inverter, very thorough testing, keep up the good work.
@Maurice1151
@Maurice1151 2 роки тому
Good video mate! I live totally off grid on my farm and have for many years and have always wanted an auto generator back up; thank you. Lots to consider.
@willienolegs8928
@willienolegs8928 2 роки тому
Been taking baby steps following you along. Outstanding!
@nate51595
@nate51595 2 роки тому
I am down in Florida and have been collecting new takeoff or slightly used 48 volt battery kits from golf carts. Right now I kind of have a jerry-rig system where I have to have a separate charger and inverter I definitely think this would be cool to play around with thanks for showing it off!
@jackpatteeuw9244
@jackpatteeuw9244 2 роки тому
Good place to start ! Lead acid batteries, especially cheap used ones are not a bad starting point. Keep them full of water and well ventilated. Make sure if you are buying a charger it can be adjusted to LiFePO4 batteries. Sooner or later you will get there. Watch the UKposts Channel DIY Solar Power with Will Prowse ukposts.info especially some of the one from last year and early this year.
@jackpatteeuw9244
@jackpatteeuw9244 2 роки тому
Technically speaking ... Your inverter, like all modern inverters, use MOSFETs and TRANSFORMERS ! A high frequency inverter uses high frequencies, MOSFETS diodes and small transformers to create high voltage (about 200V) DC. This then sent to a controller that makes it into 120VAC using more MOSFETs. The SunGoldPower inverter first creates low voltage (about 16V) AC. This is then feed, via MOSFETs, to a LARGE transformer which makes it into 120VAC. In theory, both designs work and the high frequency design is less expensive. The low frequency design seems to be more robust/durable.
@VinceBadovinatz88
@VinceBadovinatz88 Рік тому
Which kind has a higher idle consumption I've asked this question a couple times on here today. I figure somebody might see my comment and know the answer. I believe that red 1.6 amps. I'd like to convert that to watts
@LibertyDIY
@LibertyDIY 3 місяці тому
​@@VinceBadovinatz88LF has higher consumption, in this case 35W. My cheap 24V HF inverter is only 6.8W.
@LibertyDIY
@LibertyDIY 3 місяці тому
​@@VinceBadovinatz88These inverters have power save mode though which I measured about 5 watts. The problem is only certain types of loads are suitable for power save mode. Well pumps and heaters are good for that. Small loads or computer driven loads (like furnace) will not kick it on.
@VinceBadovinatz88
@VinceBadovinatz88 3 місяці тому
​@@LibertyDIYthank you
@NoelBarlau
@NoelBarlau 26 днів тому
I've had this exact unit sitting on a pallet rack in my shop for about two years, unused. A friend of mine had some kind of issue where they sent this unit instead of the one he was supposed to receive and it was apparently cheaper to tell him to keep this one instead of shipping it back to them. So I got it for a song. Anyhow, it just sat there brand new in box until a couple of days ago, when I paired it with two Lifeline AGM 255ah batteries for our camping trip. It did a great job, powering everything overnight and through the morning. Then the batteries were charged partially by two 100w solar panels during the day and then topped off by a small 2000w suitcase generator in the evening. Works great, and I'm very pleased with the setup. It'll become a permanent feature on the travel trailer, but for this permanent setup I'm going to use LFP batteries instead of the super-heavy Lifelines. They're much better suited to marine or Class A RV weight capacities.
@tonygriffiths2485
@tonygriffiths2485 2 роки тому
Am confident this video will confirm to some who need an inverter to go ahead and fit one. Good stuff, thanks :)
@flacoanemico5199
@flacoanemico5199 Рік тому
I have some welding machines from SUNGOLD, inverter type machines. They are the beast in class. I have 4 different welding machines and SUNGOLD beats them all. I have had the machine for 2 years and has been a champ. I would not be surprised that these inverters are good quality and last for some years.
@Tony-rl2fr
@Tony-rl2fr 2 роки тому
Great demonstration and review, thank you!
@stephenbullock1443
@stephenbullock1443 2 роки тому
I'm happy you tested this inverter brand.im thinking to go off grid on my home.going with 48 DC inverter.going with gel batteries and going with solar and wind
@willrobbinson1
@willrobbinson1 2 роки тому
20 hours ago That’s a super nice inverter. Thanks for showing it to us. I was hoping you had a gen-set hooked up and it was going to switch between the three modes of operation.
@jcondon1
@jcondon1 2 роки тому
I really wanted to, but do not have one that is comparable currently. Also there is only one AC input so you can run on generator or grid. Need a transfer switch to do both.
@alialhaidary1072
@alialhaidary1072 2 роки тому
This is even better than a user manual. Thanks James.
@VinceBadovinatz88
@VinceBadovinatz88 Рік тому
I know what a great review with all the testing tools
@somerandomguy3868
@somerandomguy3868 2 роки тому
Definitely a good idea, I'm going to explore it's feasibility for my application
@southpawhammer8644
@southpawhammer8644 2 роки тому
Incredibly helpful, shopping for an inverter charger for my travel trailer. Thought this one must be junk since it's almost half the price of the well known brands. This will be my inverter, thanks a lot.
@rogerandlyndabeall3840
@rogerandlyndabeall3840 2 роки тому
Watch for standby power! also the efficiency
@chrisreynolds6331
@chrisreynolds6331 Рік тому
Wow what an awesome machine! I like the fact that they've gone back to using mains frequency transformers. I have many scrap inverters in the UK where the high voltage MOSFETs have blown up horrendously and destroyed the control circuitry.
@719vol
@719vol 8 місяців тому
via internal elec auto transfer switch. No Interlock necessary.
@IvanStepaniuk
@IvanStepaniuk 2 роки тому
Nice video, thanks! I'd love to see a teardown too :-) Nice compact unit. I'd be a little concerned about having too many eggs in the same basket, though. Especially since I know that I would have to repair this myself if somethings happens to it.
@SEXYTECH1000
@SEXYTECH1000 2 роки тому
WOW, I LIKE THAT INVERTER, THANKS FOR SHARING JAMES!
@er1073
@er1073 2 роки тому
How was lunch? James this is very very impressive thanks for reviewing this inverter. It is too bad some American companies aren't doing this but that is another forum. Almost $800.00 and it does what it says it will do. Thanks again keep on keeping one James.
@philoso377
@philoso377 2 роки тому
Nice product and excellent presentation. One thing I’m hoping to see demonstrated is the transfer switching cycle - from normal grid input at 1.5~3kW, to simulated outage state, to automatic auxiliary on mode. Wait a minute, then to grid returning, to automatic auxiliary off mode and back to normal grid input. As you know most of us operate manual interlock plate by the breaker panel. Wondering how this product automated that?
@arthurbiringer5676
@arthurbiringer5676 2 роки тому
That’s a great unit! I’d love to have it. Keep up the great videos!
@wazza33racer
@wazza33racer 2 роки тому
the leading brand in off grid inverters is Victron.........multiple units can be configured for split phase,parallel units and even three phase power from 3 or 6 units. They are not made in China. Victron inverters and solar charge controllers have a lot of fine control options over battery charging configuration for all battery types ,inputs for fuel tank levels and genset start up. Multiple units can be networked for redundancy and multiple solar charge controllers can be networked to operate as a single charging unit. Victron units can also be hubbed to share data for remote monitoring..........endless features.
@nisiunavoce1264
@nisiunavoce1264 2 роки тому
Good tip with the lamp providing the initial capacitor charge, This could be very helpful to create a power conditioning circuit for pure sine wave critical devices using a non inverter generator and fairly small bank of batteries. Thanks.
@jackpatteeuw9244
@jackpatteeuw9244 2 роки тому
A 10 ohm 100 watt resistor is easier to use. Cheap on eBay.
@eddyane67
@eddyane67 Рік тому
Great review, James! Thanks
@christophermarshall5765
@christophermarshall5765 2 роки тому
Nice unit!! I've not seen ones like that here in Australia. We do have those which will charge a battery bank from a solar array system, as well as putting out mains power from the same solar array input.
@fromagefrizzbizz9377
@fromagefrizzbizz9377 2 роки тому
Every DC powered (eg: battery) UPS producing AC is an inverter by definition.
@rayshutsa6690
@rayshutsa6690 2 роки тому
Thank you very much for the information on inverters . 🇨🇦
@ItllBurnOff
@ItllBurnOff 2 роки тому
That was awesome to watch I didn't even know those existed. And I love your toys I need some of them
@billharris6886
@billharris6886 2 роки тому
Hi James, I just stumbled upon your Inverter video and have been working on a similar system for long term home backup power so, wanted to share my findings. First off, all inverters use Mosfets, there are 2 basic types: (1) High frequency inverters use a 50 kHz (25 to 100 kHz) switching power supply to boost the battery input voltage to around 200 Vdc, then they use a second switching power supply to generate a 60 Hz sinewave at 120 volts from the 200 volts. (2) Low frequency inverters use a similar high frequency switching power supply to generate a 18 volt (in the case of a 24 volt inverter) 60 Hz sinewave, which is fed to a 60 Hz step-up transformer, which is what makes the unit so heavy. The use of the 60 Hz transformer makes the unit much more electrically rugged. I spent a year and a half testing 24 volt inverters for my application. Of the 6 Chinese ones I tested, they all failed within a few months. They also did not put out rated power, overheated easily, and had poor protection circuitry. So, if you need something you can depend upon, the only one I have found super reliable under all conditions so far is the MagnaSine Magnum Energy series inverters. Lead acid batteries have a high series resistance, I don't recommend pulling more than 1/10 C current from them as a continuous rating (Yes, they will supply several times this for surges). 1/10 C means one tenth the capacity rating. As an example, for a 12 volt marine that has a 100 amp/hour rating, don't try to pull more than 10 amps from the battery. I know this seems ridiculously low but, pulling more current than this causes the series resistance of the battery to start internal heating. This is bad for 2 reasons: you are throwing battery capacity and heating the battery, which can easily take you above the maximum operating temperature of 79F/26C for lead-acid batteries.
@jcondon1
@jcondon1 2 роки тому
Thanks Bill, I appreciate the insight.
@robertgad3269
@robertgad3269 2 роки тому
Very interesting. Based on your video, this appears to be a modernized version of a device known as the "Heart Interface, which has been around since the 1980s and widely used in sailboats. I have two Hearts: one has been in use in my boat since 1991; the other supplies AC to a critical communications repeater and has been in use since about 1995. Both of my Heart's run on 12VDC: the boat one is connected to 400AH of East Penn gel cels, and the radio one to 200AH of same. One difference is the the Hearts are MSW, versus PSW. I suggest two questions that it would be nice to answer. The easy one is transfer time from shore power to inverter on loss of shore. This was important for the radio system because the radio (a Motorola Quantwr) is computer controlled, with a long boot up cycle on initial power up. We found that on interrupting shore power the Heart swtiched fast enough that the Quantar doesn't see loss and doesn't reboot. We later measured transfer time and got a result (from memory) of about 18 Ms. The second question is long term reliability, a question the answer to which requires some long term experience. Our Hearts were made in Washington state, though I believe current ones are made in Canada. The Sun Power is made in China. Anyhow, enjoyed your video. The potential applications for devices of this type are virtually unlimited.
@jackpatteeuw9244
@jackpatteeuw9244 2 роки тому
The original Heart Interface inverters created a "modified sine wave". Not the best for heavy loads like microwave or that compressor. Some companies still make modified sine wave inverter, but I would not recommend them. Even though they charge a lot more for a pure sine wave inverter it is worth the money. Modern pure sine wave inverters, especially the high frequency one, really only cost a few dollars for to build compared to the modified sine wave inverters, but companies get away with it !
@fromagefrizzbizz9377
@fromagefrizzbizz9377 2 роки тому
Inverters have been around from the late 19th century. Early ones tended to be mechanical - eg: a DC power source driving a generator, or such exotic devices such as amplidynes (I worked on a radar/radio telescope built out of a cold-war DEW radar station, and used to drive the "aiming" motors). In fact, as I understand it, this same unit was used in WWII battleship MIssouri-class main turrets). In 1957 thyristers (SCRs and Triacs) were invented, and they became fully solid state. After, they started using power FETS, vFETs, SOS FETS and lately the legendary igFET which allow you to convert your entire public power grid to DC except for local distribution lines. [Most FETs are Metal-oxide semi-conductor (MOS). So are most high density microcomputers of one form or another. That's further divided into many different categories, like nMOS, pMOS, SOS and igFETs] We replaced the 4'x8'x8' dish power unit, that weighed over a ton with two 500 pound amplidynes, and vacuum tubes the size of your head with a box about the size of a breadbox with igFET bridges. In essence, if you took one of Condon's gasoline generators, and replaced the motor with a DC motor, you'd have an old-fashioned rotary inverter with an effectively pure sine wave output. Every battery-based UPS is an inverter. The only real difference is how true the output AC is to a sine wave. Brushless battery power tools are *effectively* DC to AC inverters where you can change the output frequency and thus vary the speed of an AC induction/synchronous motor. [DC distribution in high voltage lines avoids the 10-15% loss in skin effect at 60hz long haul AC. And completely eliminates the need to synchronize power production generators when you need to share load.] The "Heart Interface" is just the name of one company who specialised, at the beginning, in small-medium marine applications. As for long term reliability, do remember where most chips come from these days. North American ones (Heart Interface was subsumed into Schneider Electric - a French megacorp multi-national) may be mechanically nicer and more solid, but the guts are really not that much different, and often exactly the same electronic components.
@emylrmm
@emylrmm Рік тому
Heart Interface made the FDM 458 modified sine wave inverter/ chargers. That UL listed inverter/charger series is still sold today under the Xantrex brand. Xantrex is now an MCE company headquartered in Costa Mesa, California.
@richardgregor2108
@richardgregor2108 2 роки тому
This converter is something mywife and I sure could use it do to our temp R.V living and our solar charging system and our generator this would be a great gift step up thank you for listening Sincerely R.&L Gregor your channel has been great at helping some of our solutions
@mikelayne6973
@mikelayne6973 2 роки тому
Yes ,I live off the grid and I would really like to have this inverter becauseI can use it with my battery pack.
@jimmurphy5355
@jimmurphy5355 2 роки тому
"Low Frequency" inverters have MOS-FETs. Just like a high frequency inverter. The difference is the voltage they are used at. In this LF inverter, the MOS-FETs are running directly off the battery voltage, and synthesize a low voltage mains frequency sine wave by switching the battery at high frequency using PWM . This makes about 18 VAC at 60 Hz in a 24 volt unit like the one you reviewed. The 60Hz 18 VAC sine wave is sent to a large step up transformer to raise it to 120/240 VAC In a high frequency inverter the voltage from the battery is sent to a DC-DC boost converter that makes ~350 VDC. Then MOS-FETs are used to directly synthesize a 60 Hz sine wave directly at the target line voltage using the same method as was used in the LF inverter, except for the fact the voltage was boosted in the DC realm instead of in the AC realm.
@MikinessAnalog
@MikinessAnalog Рік тому
I like those as they have the same transformer that charges the batteries to also be the step-up transformer. In charge mode, the output is center tapped at 2 rails of 12 volts AC (24 total). In inverter mode, the mosfets "swing" the input voltage back and forth at 2 rails of 12 volts AC.
@eddietee6305
@eddietee6305 Рік тому
Great explanation. I hope the subscribers read your comments. I just stated briefly above that the unit MUST use a switching device such as a MOSFET. A transformer cannot provide switching. That is not up for argument.
@TheBeardedDog
@TheBeardedDog 2 роки тому
This is definitely a competitive offering. Thanks for sharing.
@pcas96
@pcas96 2 роки тому
Thanks for a really thorough review I am very impressed with Sungold
@larryzakharov6310
@larryzakharov6310 2 роки тому
Thanks for a nice, technical review
@Popeyes66
@Popeyes66 2 роки тому
Eloquently presented James.
@rogerandlyndabeall3840
@rogerandlyndabeall3840 2 роки тому
I use Victron inverters, they have low standby power at no load (2 watts) and very high efficiency (98%) They also have the ability to use the inverter to boost the mains input power if perhaps it is not enough for an application. Victron used to use low frequency heavy toroids 5 years ago, but now they all use high frequency. Still have a surge of 2x inverter capacity. A 500w Victron runs and starts my refrigerator fine- my 1600 watt runs 4 refrigerators simultaneously.
@KuntalGhosh
@KuntalGhosh 2 роки тому
98% efficiency cus it's using switch mode topology. Those can't handle heavy current surge.. u should try running a non inverter ac on it and see how it does 😂. These low frequency bois can handle 3x 4x surge like seen with the air compressor. Refrigerators are not a huge load and they don't have a ton of starting current..
@talusranch990
@talusranch990 2 роки тому
Victron is all marketing and is crap.
@shanonqual759
@shanonqual759 2 роки тому
@@talusranch990 you cant afford victron, you got butt hurt!!!
@VinceBadovinatz88
@VinceBadovinatz88 Рік тому
What is the idle consumption on the sun gold. I think it said 1.6 amps but I don't know how to convert that to watts.. I need to learn how to do that because they all come in amps well they don't all say amps. The all-in-one inverter 2424 mPP uses 50 that's the only drawback to those well I don't know about the only but that's the biggest one. I wonder what the 1.6 amps on this means
@squenix8444
@squenix8444 2 роки тому
Very nice!, thanks! I'd love to see for the sake of curiosity the difference with a high frequency one, delivering the same power.
@derf_the_mule1405
@derf_the_mule1405 2 роки тому
Watch out for those Made in China cables. They tend to send CCA crap instead of copper wires. The CCA works fine until you get to 50% capacity or a few years old and corrodes to crap (putting it nicely).
@jackpatteeuw9244
@jackpatteeuw9244 2 роки тому
CONCUR ! Invest in some large (4 AWG ?) cable. You can find places on eBay that will make them to whatever length you want. If you are going to be doing a lot of solar/inverter/charge work, you might be better off buy cable in bulk and a crimper. Even the hammer crimpers are pretty good.
@billharris6886
@billharris6886 2 роки тому
I have had some of those Chinese cables actually made from copper plated aluminum wire, which as a notably higher DC resistance. I also make my own cables. Sometimes it can be hard to find the exact terminal lug I need so, I have made several from copper tubing, which I then crimp using a hydraulic crimper. I need to go a step further and buy a solder pot to solder the terminals after being crimped to reduce resistance. With 100 amps flowing, the least little bit of resistance quickly starts heating.
@barryjameson3113
@barryjameson3113 2 роки тому
I actually bought this exact one (12 volt version) in 2020. The cables were way undersized. Better go big or go .....
@mrmotofy
@mrmotofy Рік тому
@@jackpatteeuw9244 A 3000w should be more like 4/0 and short as possible. A 2000w should be more like 2/0. The included are never near large enough. Tons of RVers have figured out many of their problems running these larger units is small cables. Welders cable works well
@clarkcasey505
@clarkcasey505 2 роки тому
Would like to see it start charging when the batty voltage drops to Low. Like all your videos.
@remushaynes2693
@remushaynes2693 2 роки тому
greetings sir; i am very pleased to have happened up on your channel as it is very informative, interesting and easily followed. also, it is narrated without the use of profanity that i am finding almost everywhere lately. i learned a long time ago to carry on a conversation without it and am enjoying life so much. i have some of the equipment you service and find your videos very helpful...............g
@jcondon1
@jcondon1 2 роки тому
Thanks. Try to keep profanity to a minimum and always edit it out.
@peterking1134
@peterking1134 2 роки тому
Something new is always good!
@songreosmenep
@songreosmenep 2 роки тому
That Inverter worrks like a boss! I had no doubts it could do all the things you wanted to do. By the way are all these low frequency?
@CajunGreenMan
@CajunGreenMan 2 роки тому
I really hope you're kidding when you said your favorite meal was a microwave dinner. Cool bit if kit, look forward to seeing it tested to automatically turn on your generator when you find one that's compatible. Keep up the great work!
@jcondon1
@jcondon1 2 роки тому
That was my favorite "microwave" meal.
@chucktrotter9699
@chucktrotter9699 2 роки тому
8.19.21 Nice video James. Are going to to a solar panel install and use the growatt inverter 5kw to run your garage on?
@Farm_fab
@Farm_fab 2 роки тому
Jim, I'm planning on going with solar panels, and I have a diesel engine that I can mount a military alternator on since it is 24 volts.
@probeteam9936
@probeteam9936 2 роки тому
Very interesting item... and a very good description... thank you...
@PinnacIeSaint
@PinnacIeSaint 2 роки тому
I have considered getting a full home generator for a long time for emergencies and ultimately decided on an inverter installed in my truck. my main issue with the generator was the noise and with the inverter in the truck it's much quieter and at a normal idle the truck can actually run for a really long time. It's only a chevy trailblazer so it's just regular fuel not diesel and in emergency situations it does awesome. I can easily run a full size fridge, lighting, and even TVs and computers with no problem not to mention making sure cell phones stay charged. I do get a little nervous leaving the truck running with no one inside it. but in those emergency situations it's typically pouring down rain and lightening so i doubt anyone would be outside thinking of stealing a car.
@jcondon1
@jcondon1 2 роки тому
That is a good idea. Most cars can produce around 1000 watts at 120 volts and up to about 3,000 watts continuous. The car battery can easily absorb surges associated inductive loads.
@billharris6886
@billharris6886 2 роки тому
Been there, done that. At idle, there is only about 30 amps available from an automotive electrical system, assuming nothing else on the car that consumes power is turned off. That translates to 300 to 360 watts of inverter output power. You can pull more current than this but, you will cook your alternator. I would leave the hood up while the engine is running and (of course) the car would need to have its exhaust routed to the outside at least 25 feet away from your house. Although this method works okay in emergencies, I would recommend using an inverter generator instead for something more permanent. They are fairly quiet and get better gas mileage than a simple open frame portable generator.
@mrmotofy
@mrmotofy Рік тому
@@billharris6886 Yep agree, the Harbor Freight Predator Inverter line is pretty good, the 3500 is a popular option/size.
@PaulAckermanDanseBleue
@PaulAckermanDanseBleue 2 роки тому
Sun Gold looks EXACTLY like the AIMS Corp unity out of Nevada. AIMS user manual is detailed, and their user support is difficult. Thanks for your nice review. Just compared the 2 manuals, and they are the same, with Suns having made a few minor changes. Aims unit for 3k is $1.200.00 and Sun is $750.00. No status LED read out on the AIMS unit.
@mrmotofy
@mrmotofy Рік тому
There's a lot of the companies that sell essentially the same thing. Snap On sued Harbor Freight over a floor jack...it came out in the trial. HF bought from a catalog of a Chinese manufacturer...OOOPSIE so did Snap ON LOL so they lost. Tons of relabeling going on. Those fancy $2-300 computer gaming chairs...Yep you can buy one customized for you for about $75.
@o.g.solutions
@o.g.solutions Рік тому
Actually sungold was around first, Aims possibly procures its producs from sungold..?.I remember when aims products were terrible..and then they came out with their low frequency (sungold clone) I think it's what saved that company.....
@allenedwards7108
@allenedwards7108 2 місяці тому
Very informative thank you. I think this setup is going to be way less complicated than my original plan.
@shawnmrfixitlee6478
@shawnmrfixitlee6478 2 роки тому
Great unit James . A bit pricey but very heavy duty ! ENJOYED..
@billhackley3540
@billhackley3540 2 роки тому
did you do this test without the earth ground lug below the dc hookups attached, my dc side works fine but 120 won't light up. wondered if it needed the earth ground hooked up
@curtchase3730
@curtchase3730 2 роки тому
Nice review. What impressed me was the relatively low quiescent current draw (no load). Not much more than my 3500 watt Reliable hi freq unit. Too bad you did not show the max inrush amps from batteries to inverter when starting that direct drive air compressor! Not all clamp meters can do a peak current though. I have an old 1200 watt modified squarewave inverter (12v) that will pull over 300 amps for a split second when starting, say a de-humidifer compressor!
@jcondon1
@jcondon1 2 роки тому
Need to upgrade my tooling.
@VinceBadovinatz88
@VinceBadovinatz88 Рік тому
​@James Condon it's been a year you probably got that different tester, 😊. You don't happen to know the idle consumption in Watts by chance do you. Or could you explain how convert idle consumption from amps to watts. Thanks in advance
@davidhelmuth6654
@davidhelmuth6654 2 роки тому
Great information. Thank you
@matthewgrills4135
@matthewgrills4135 2 роки тому
Hey Jim. I couldn’t find a place to contact you directly so I’m hijacking this vid comment page for a moment. I’m amazed and enthralled with your vids and have been watching them for days. Small engine repair has always vexed me but you make it so manageable and systematic that it looks easy now. My comment is I would love to see some vids on your “philosophies” and opinions about the stuff you use. What type and brands of oils and fluids you use and why, a user vid on you very cool ultrasonic cleaner and what is that yellow stuff you add? Is there a favorite? Any commentary on tools, shops, how you find all these used junk generators and how divers is your business? Are you just generators or do you do other stuff too? Let us into the life of James Condon.
@anerepol
@anerepol 2 роки тому
Have been installing sungold inverter for more than 10 year. Never had a client compliant with this brand. Great video
@3D_Printing
@3D_Printing Рік тому
4000W DC 12V PURE SINE WAVE INVERTER WITH CHARGER $998.00 Looks like a good price compared to some others
@taylorlapham6367
@taylorlapham6367 Рік тому
That looks just like my Aims inverter I installed in 2012. Same features
@graywolf2694
@graywolf2694 2 роки тому
Damn wish i new about these when I was upgrading the rv
@notyoung
@notyoung 2 роки тому
I like the surge capability of the SunGold but I've been using high frequency inverters (active & spare) from Reliable Power (now WZRELB on Ebay) for 4 years in my "Wait until daylight" solar-charged backup power system. The 2000 watt pure sine wave inverter was chosen to handle the maximum normal load of 1350 watts (just under 70% of the inverter's rating) and it has no problem starting the essential things (fridge, freezer, furnace blower). After one trip outside to shovel 7" of snow in the dark at 30F to get a generator out of a shed, I decided there had to be a better way ;-) A gasoline generator is still the fallback if there isn't enough sun but, depending on the season, the solar backup system can provide 8 to 20 hours of limited power - 20 hours if only powering the fridge, less time if the freezer needs some cooling or we need the furnace. No "bells and whistles" on the inverters (charger, gen start, etc) but they have survived 4+ years so they are fine for my needs. The gasoline generator is actually a hierarchy of generators: 1600 watt inverter gen for limited power and recharging the battery bank if there is no sun (most efficient); 3000 watt 120 volt gen if I need corded hand tools; 5000 watt 120/240 volt gen if I need the 10" table saw or the air compressor. Longest outage we've used the solar backup for was 12 hours in December - with snow taking down power lines. It worked for my design time, so I was happy. No, I haven't tried to start any large, high-start-current tools with these inverters. I know that some 10" and larger chop saws can have a 40 amp or greater start surge which very few inverters smaller than 10KW can handle. My spreadsheet for "What things for how long?" on the solar backup has a page which includes average running power, maximum running power (defrost cycle on fridge or freezer takes more power than running the compressor) and starting power plus cells which go red if you exceed the inverter's ratings - nice to be able to say "You can use the garage door opener if I unplug the fridge and freezer for a few minutes" - all can be run at the same time but not all can be started at the same instant so you need to ensure controlled motor starting - timers work well to prevent simultaneous fridge and freezer starts: two hours on; two hours off and a 3-5 minute gap between those times or whatever works for your appliances. Inverter power is fed to selected circuits via a transfer switch, which is also where the gas generator connects through a 12/3 cable. The 5000 watt gen has a 4 prong plug connected to a double duplex outlet via adequate wiring - one outlet on each side of the 240 - so I can power multiple larger tools at the same time and still charge the battery bank, if needed.
@VinceBadovinatz88
@VinceBadovinatz88 Рік тому
Good comment I was wondering about those inverters seeing them advertised. A lot of the reviews weren't so great I don't think
@lot27a
@lot27a 2 роки тому
I'm guessing James doesn't sweat power outages at all. Very informative. One of these days solar will be making an appearance at the homestead but for now I'm just keeping the generator at the ready...
@sgtJOOSEcapeS
@sgtJOOSEcapeS 2 роки тому
James probably looks forward to it 😜...
@tarstarkusz
@tarstarkusz 2 роки тому
Most solar setups are simply not worth it and are subsidized and cannot use a battery back up and you will lose power if the grid goes down even if it is solar noon in your locale. This is the law in most places now. The battery is a huge part of a good solar installation and they cost a fortune, even for lead acid. Quality lead acid batteries start around a thousand bucks. Also, I am guessing (though I'm not certain) this is probably not suitable for a proper solar setup with batteries. Generally, the really good reliable inverters are North of a thousand bucks. This stuff just is not cheap. Even this unit is like 800 dollars.
@jackpatteeuw9244
@jackpatteeuw9244 2 роки тому
We had only the 3rd power outage that lasted longer than the 40+ years I have lived in my home. Generator was ready. Lots of HD extension cords. I ran 3 house (mostly refrigerators) 14+ hours/day for 4 days. No problems.
@jacklewis100
@jacklewis100 Рік тому
The generator start is nice... but where can I find an AUTOMATIC transfer switch to switch between generator and mains AC ? Lots of manual switches but I can't find an automatic one...
@liviu2004
@liviu2004 2 роки тому
What’s the short circuit output capacity, thus operating mode not constant voltage but constant current? At 0v?
@alansmith4734
@alansmith4734 2 роки тому
Interesting! You could run a Battery Tender Trickle Charger, and charge up the Batteries!
@estruble
@estruble 2 роки тому
Thanks for the presentation. An interesting product that might be useful for some applications. I went to Sun Gold Power's web site and was looking at some of their other products and I was astonished to find (at least what it looks like to me) that the utility connectors on all the models look similar to the one you tested. While those connectors might be fine for 25A @ 120V, in no way would they be capable of providing 18000 Watts of power on a split phase inverter setup. Do these have any agency approvals? If you used for your home backup and something went wrong, i.e. the apparent undersized output logs burned up, your insurance company would say NO, you're on your own... But, don't get me wrong, it's an interesting product that has it's uses but from the images on the web site I was concerned about the robustness of the connectors being able to handle the loads they specify. Eric
@mrmotofy
@mrmotofy Рік тому
They could...depending on the voltage, the capability is usually rated in amps, but that will change the total wattage that can run through there at a higher voltage. Basic Ohms law. So a contact rated at 15A at 120v is 1800w, but at 240v that's 3600w. It can all be done by calculations
@nicmost3044
@nicmost3044 2 роки тому
James, don't turn it on. Take it apart. I want to see the inside. Thanks for the videos anyway, Like watching them because I learn a lot.
@kevinlawrence7623
@kevinlawrence7623 2 роки тому
Very good review, as expected.
@jeffsorensen9657
@jeffsorensen9657 10 місяців тому
I have this Sun Gold Power inverter at an off-grid seasonal cabin. It is turned off when I am not there. It’s under two years old and has worked fine since it was installed. It recently started to turn itself off after being on for about 15 seconds. Upon turning it to the off position and restarting it, it again continues to shut itself off within a minute. The LED readout is scrambled and unrecognizable. Any thought on what is causing this to occur?
@Happyhound33
@Happyhound33 2 роки тому
great vid.....thanks
@KensSmallEngineRepair
@KensSmallEngineRepair 2 роки тому
I’m glad I studied ME and not EE!! 1.21 Gigawatts to the flux capacitor Professor!!
@jeffcornelison888
@jeffcornelison888 8 місяців тому
Great video!
@Ian-pe9rj
@Ian-pe9rj 2 роки тому
All inverters are driven by MOSFETs or IGBTs, the differences are if the transistors are before or after the transformer, and the switching frequency used to boost the voltage from battery voltage to line voltage.
@jamesfalvey77
@jamesfalvey77 3 місяці тому
I know I'm 2 years late, however, I would have liked to have seen the charging current. I have had "name brand" chargers before that listed a certain current, however, they were unable to produce it. The battery charger alone has me second guessing this product because I have yet to see actual amperage. Thanks for the video
@whitesapphire5865
@whitesapphire5865 2 роки тому
That's probably the way to go for most of us, eventually. It is effectively a big UPS with nice extra features. I'd say, go for the 48v input, and halve the current draw from the batteries. I like the practical test, nuking a lasagne for dinner! What sort of money are we looking at for one of these inverters?
@jcondon1
@jcondon1 2 роки тому
They are not cheap. This one is in the $800 range.
@whitesapphire5865
@whitesapphire5865 2 роки тому
@@jcondon1 I guess you could say "ouch" to the price, but I'd hazard a guess that like most things, the costs, and eventually retail price should fall, but for now, I think only a serious need would force me to buy one. One good reason might be to have the advantage of short term power restored without upsetting the neighborhood, especially in the late evening, otherwise, if like us you're lucky enough to be rural, stick with a reliable generator.
@FastJohnny80
@FastJohnny80 2 роки тому
I ordered one of these to backup a sump pump, pellet stove, and fridge. I also went with the 24V and 2 - 200A LifePo batteries. Any info on wiring one of these to a sub-panel? I'm not sure how the hot line would connect to a panel designed for 240V with 2 hot inputs? Do you run a jumper between the 2 hots?
@jcondon1
@jcondon1 2 роки тому
I have not wired one of these to my house. Without knowing your setup it is hard to comment.
@curtdunlap6818
@curtdunlap6818 2 роки тому
This particular model's sub-panel output is only for 120V applications according to the website description. In spite of that, I'm glad James did this video. It never showed up on my radar when I was looking for a sump pump backup inverter. The Pump Sentry I bought last year only fried my sump pump when I tested the load interruption and caused a voltage surge, and it was back to the manufacturer for that one! Thanks again for the video and the links, James!
@benkanobe7500
@benkanobe7500 Рік тому
Where did you tap in your O-Scope to display the sine wave?
@VinceBadovinatz88
@VinceBadovinatz88 Рік тому
I know right I don't know much about oscilloscopes anyway
@eshskis1
@eshskis1 2 роки тому
Great product review !
@jcondon1
@jcondon1 2 роки тому
Thank you!
@mrbuilder2k99
@mrbuilder2k99 2 роки тому
Good Morning James. I hope that you and yours are doing well. You are correct about MOSFET. Unless they have major heat sink and cooling they tend to have problems. Thank you for sharing with us. This unit is sweet. I've seen some G.E generators over the years with auto-sense feature. What would you consider to be the best configuration when using six or eight 12 volt deep cycle marine batteries? Thank you and have a great day.
@jcondon1
@jcondon1 2 роки тому
Would recommend running at 48 volts DC or higher if your system allows it. Might also be an advantage to using lower voltage batteries in the 6 or 8 volt range.
@eddietee6305
@eddietee6305 Рік тому
Thr inverter has to use a switching device such as a MOSFET or IGBT. The transformer cannot provide that. I'm almost certain that this particular unit uses MOSFET switching.
@peterecklund886
@peterecklund886 2 роки тому
Wish list material. What is your setup and how do you plan to use this item?
@videobydano
@videobydano 3 місяці тому
@2:07 Regarding Automatic Generator Start (AGS), have you tried that? I have had difficulty getting the SunGoldPower 3000W inverter AGS to start or stop my 2020 Onan 2500 LP generator using the inverter's AGS dry contacts. For those unfamiliar, dry contacts are a safe and standard interface for many worldwide generators that provide the automatic remote start function when the battery voltage gets low (10/10.5V). Can you kindly demonstrate the AGS on this inverter?
@vk5744
@vk5744 2 роки тому
Hey James - great video! Can you show us how you would hook up the inverter with a generator? I have a sump pump and think it would be perfect for inverter/battery/auto generator start application
@jcondon1
@jcondon1 2 роки тому
Wish I could, but do not have a generator that is compatible.
@vk5744
@vk5744 2 роки тому
@@jcondon1 I was looking at the specs. There’s no list of compatible gens. Are you referring to where it says the. Gen must be 1.5x greater than the inverter?
@nigelpearson6664
@nigelpearson6664 2 роки тому
Very interesting when using the microwave against other loads. I think the unit will be MOS FET as the current in current out suggests that. The US army used rotary converters in the 1940, That would be the easier non MOS FET route. The microwave gives a very typical MOS FET working hard look. It could be a hybrid design, THD tyupical is about 3% at a guess. Not bad.
@Max-kn9yi
@Max-kn9yi Рік тому
You can directly attach this to your home power? Does it give you the items to do this? This will then use the homes ac when the batteries become to low? Could it sense that the homes power doesn't have enough Amps on the particular circuit(due to other things pulling from that circuit) and then pull from batteries?
@jcondon1
@jcondon1 Рік тому
It does not come with anything to connect to your house. It could be connected in such a way to power a couple circuits in your house. It will automatically charge you batteries and if the voltage drops low or utility power is lost, those circuits will keep running.
@sh839c
@sh839c 2 роки тому
What generators are compatible with the 2 wire start function?. I can't find any information on this or how to set up a remote start generator to work with this inverter feature. Thanks for an excellent channel.
@jcondon1
@jcondon1 2 роки тому
Not sure. I only researched if my EU6500 could do it. Might have been possible, but would have been a hack. Maybe large non portable generators might be comparable.
@clayharris7814
@clayharris7814 Рік тому
The only that I have witnessed on UKposts is aims generator look Gavins garage he has a video for that
@kidders31
@kidders31 Рік тому
Hi what battery’s you use for this please
@wim0104
@wim0104 2 роки тому
What's your Tacklife meter model# ? I love their compact clamp meters!
@wim0104
@wim0104 2 роки тому
CM01A, they're up to the CM06 now
@patrickcoleman5867
@patrickcoleman5867 Рік тому
I love your videos they are very detailed. I have a question I can’t get an answer for. I have a portable backup generator that is not a inverter. It’s 17,500 watts running and 26000 start up. I’m not sure what THD is but I’m sure it’s above 5. I m worried about my refrigerator and LCD tv getting destroyed. I was thinking about buying a few power inverters and somehow through a power supply plug them into the wall then plug the TV or refrigerator into the inverter to get a pure sine wave. Can this be done and if so how. Because I’ll have the house powered through the generator I thought I could power the inverter through wall ac power any help will be very appreciated.
@markhemingway8916
@markhemingway8916 2 роки тому
Would it run a TV VCR descrambler antenna off of a car battery in a car
@jcondon1
@jcondon1 2 роки тому
It would if you had the 12 volt version of this.
@gramsfarm7557
@gramsfarm7557 Рік тому
I am hoping you can give me some clarity on this. I purchased this inverter and two 550 watt panels. I am wanting to do grid tie. From what I understand I can use this as a grid tie as well. Could you give clear this up.
@jcondon1
@jcondon1 Рік тому
I do not believe this model can support that. They do sell others that can grid back feed.
@jayyoung5423
@jayyoung5423 2 роки тому
Great job...I see the CE mark, is there a UL?
@jcondon1
@jcondon1 2 роки тому
Do not think so.
@douglaswindsor120
@douglaswindsor120 2 роки тому
If your lights dim when your compressor kick's om open your panel box up and check to make sure that all the screws are tight check the common grounds I had this problem and found most were at least a half turn some were as much as 2 with all that resistance gone it not only fixed the problem my power bill dropped too
@jcondon1
@jcondon1 2 роки тому
Would not surprise me. Have found a lot of wiring issues in my house over the years.
@hieyeque1
@hieyeque1 Рік тому
Hi James, does it convert the square sine wave power from the generator to a clean up pure sine wave?
@jcondon1
@jcondon1 Рік тому
It does not
@VinceBadovinatz88
@VinceBadovinatz88 Рік тому
​@@jcondon1 I hear those kind of generators mess up the inverters when they are charging the batteries. I think eg4 is selling a 48 V charger now because of that. That's in those all in ones
@arthurbiringer5676
@arthurbiringer5676 2 роки тому
After the review did you have to return the unit? Was it a freebie? Freebie is great!
@emylrmm
@emylrmm Рік тому
For safety, shock and fire, I recommend puchasing an inverter/charger which has UL Listing mark or equivalent 3rd party approval.
@chspyderr
@chspyderr 2 роки тому
Amazon is listening! Lol I just viewed these and split phase versions of these as an alternative to aims. As anyone used a split phase version of these?
@YukonHawk1
@YukonHawk1 2 роки тому
Nice having coffee with you today. Even though I was looking forward to a carb cleaning🤣🤣🤣 this was more interesting.🤣🤣🤣 Very cool product.
@richrappa7906
@richrappa7906 2 роки тому
Great stuff. Thanks. Has anyone installed this in a semi truck with a ThermoKing Tripack evolution?
@redneckbryon
@redneckbryon 2 роки тому
I’m surprise that little air compressor dim the lights mine is twice that size it’s supposed be started on 20 A but even on 15 A it doesn’t dim the lights.
@soulkeeper514
@soulkeeper514 2 роки тому
I have one of those split-phase model hookup to my whole house, pair of Lifepo4 battery's runs all my house including my water heater (3800w) 240v with out any problems, all so have a Victron charge controller width a couple solar panel to charge my battery's , so yeah you can use one of does for off grid if you have a large enough battery bank for pass the night and day's that there is not much sun light , the internal ATS of this units would keep you desktop computer on ,some times you would never know if there is power lost in the grid, yes is that fast the ATS
@AndrewBrowner
@AndrewBrowner 2 роки тому
2 questions this video brought to mind when trying to measure DC current with a clamp meter are there any special steps you need to take vs AC, does it only work on pricier meters that state they can do it or are the mechanics behind how its measured the same for both AC and DC? second when buying batteries theres typically an AH rating on them, what exactly does this tell you? how many amps itll put out until it drops below 12volts? 11volts? wheres the cutoff or is that the amps contained in the battery if you drain it right to nothing? depending on the answer to this question can you simply take the AH of the battery multiply it by 12 and get the WH the battery will put out for the the inverter before going flat of course with some margin or error favoring low long loads like lights vs high draw items like microwaves and power tools
@notyoung
@notyoung 2 роки тому
That's usually two entirely different types of metering these days. AC clamp-on current meters use the clamp as the secondary "winding" of a transformer and the wire running through it is the primary "winding". The AC voltage the meter reads via that transformer is scaled to display AC amps. Most DC clamp-on current meters now use a Hall-effect sensor (sensitive to the magnetic field the DC current induces in the wire it's clamped around) and that magnetic field reading is scaled to DC amps. Some meters may use Hall-effect sensors for both AC and DC. You should probably spend some hours at batteryuniversity.com as they can tell you more than you ever wanted to know about all types of batteries ;-) The AH rating of a battery is based on testing done for 8, 10 or 20 hours (depending on the battery's intended use). Most vehicle batteries (and those for UPS units and many solar applications) have a 20 hour rating. A 100AH battery can deliver 5 amps for 20 hours (5 * 20 = 100) BUT there are a number of "gotcha's", depending on the type of battery. A typical vehicle battery (SLI - starting, lighting, ignition) is a FLA (flooded lead acid) battery - the type you must check the water level on occasionally. Some newer vehicles use AGM (absorbed glass mat) batteries which are sealed, with the acid trapped in a fiberglass mat so the battery never needs water and can be used in any position (you'll also find these and gel batteries in electric wheelchairs and handicap scooters). Some FLA batteries are designed for long service at high loads (forklift, solar power, submarines) and can last many years. Newer battery technologies use lithium instead of lead-acid and can have longer life - but cost more. SLI batteries are designed for the quick, high current engine start and immediate recharge but don't last if subjected to discharges greater than 20% or so. AGM batteries can provide 350 charge/discharge cycles if discharged 80% or 1200 charge/discharge cycles if only discharged 50%. Most lithium-ion cells can provide 500 cycles if discharged 80%, but perhaps 3-4 times that if only discharged 50%. LiFePO4 cells can provide 1000-2000 cycles if discharged 80% and probably double that if only discharged 50%. LiFePO4 batteries can be made up that match the voltage range of lead-acid batteries so they are almost a drop-in replacement - 12, 25 or 48 volts. Lithium-ion batteries can be made that work in place of 24 or 48 volt lead-acid batteries but they are NOT a drop-in replacement - things usually need some tweaking. If you can only use 50% of a 100AH battery, you only have 50AH to work with at that level of battery cycle life so you must compute how many charge/discharge cycles you need from the battery bank, how much space and money you have and then work out which type battery and how many AH to power your needs for XXX hours. There is no easy answer because it depends on YOUR needs and YOUR available funds.
@VinceBadovinatz88
@VinceBadovinatz88 Рік тому
​@@notyoung dang that was a good comment thanks for the info I've been messing around with this stuff for a while now but it's always good to read it again
Sungoldpower pure sine wave inverter charger 3KW 12V low frequency
14:17
Land to House
Переглядів 11 тис.
Sun Gold Power 6000w Pure Sine Wave Inverter and Charger
15:00
Land to House
Переглядів 85 тис.
Godzilla Attacks Brawl Stars!!!
00:39
Brawl Stars
Переглядів 4,8 млн
Reliable Brand(WZRELB) 3000W/6000W Surge OFF-GRID Power Inverter Tests!
22:26
electronicsNmore
Переглядів 148 тис.
The Top 9 Lithium Battery Mistakes for Van and RV Power Systems
24:50
Ross Lukeman
Переглядів 231 тис.
Sun Gold Power 4000W, 12V, Inverter/Charger combo for the budget RV life
24:59
How Many Batteries For a 3000W Inverter?
6:09
Cleversolarpower
Переглядів 565 тис.
6000XP VS Low Frequency Inverters. There's no contest.
4:19
Kick Gas
Переглядів 6 тис.
Giandel 3000W Pure Sine Wave Power Inverter  Review
16:16
jehugarcia
Переглядів 105 тис.
3000W/6000W Off-Grid Pure Sine Wave Inverter Any Good? Find Out!
16:08
electronicsNmore
Переглядів 182 тис.